SearcharxivSearch

arXiv subjects

Axel Loewe

Publications and source records attributed to Axel Loewe.

17 recordsLinked to original sources

Characterizing In-the-Wild Personal Listening Device Use to Inform Earable Application Design

Ear-worn devices are evolving from audio-playback tools into sensing platforms for health, interaction, and context-awareness. Yet, earable systems are typically designed and evaluated under strong assumptions about how long, how often, and in which situations people actually wear personal listening devices (PLDs). To ground these assumptions in-the-wild behavior, we combine a survey of 330 adults with multi-year, passively logged headphone audio-exposure records donated via Apple Health by 90 of them. We characterize where and when people use PLDs, how logged use has changed in recent years, and how psychological traits and social context associate with PLD usage. Our results show that logged mean daily use has increased from 37 minutes in 2020 to 64 minutes in 2024. Listening was intermittent: no listening was logged on 48% of participant-days in 2024, and sessions were fewer but longer on weekends. Sensation seeking, particularly disinhibition, showed small to medium positive associations with self-reported PLD use. Younger adults listened at higher volumes than the 25-34 group. High-volume exposure was uncommon, with only 4% of participant-weeks exceeding World Health Organization (WHO) safe-listening limits. Finally, most participants also reported avoiding PLD use in social situations. We translate these findings into implications for earable computing: realistic expectations of intermittent rather than continuous wear, contextual coverage that anticipates systematic gaps, targeted safe-listening interventions, and personalization grounded in psychosocial and demographic profiles rather than assumptions of uniform use.

cs.HC

Computerized Modeling of Electrophysiology and Pathoelectrophysiology of the Atria -- How Much Detail is Needed?

This review focuses on the computerized modeling of the electrophysiology of the human atria, emphasizing the simulation of common arrhythmias such as atrial flutter (AFlut) and atrial fibrillation (AFib). Which components of the model are necessary to accurately model arrhythmogenic tissue modifications, including remodeling, cardiomyopathy, and fibrosis, to ensure reliable simulations? The central question explored is the level of detail required for trustworthy simulations for a specific context of use. The review discusses the balance between model complexity and computational efficiency, highlighting the risks of oversimplification and excessive detail. It covers various aspects of atrial modeling, from cellular to whole atria levels, including the influence of atrial geometry, fiber direction, anisotropy, and wall thickness on simulation outcomes. The article also examines the impact of different modeling approaches, such as volumetric 3D models, bilayer models, and single surface models, on the realism of simulations. In addition, it reviews the latest advances in the modeling of fibrotic tissue and the verification and validation of atrial models. The intended use of these models in planning and optimization of atrial ablation strategies is discussed, with a focus on personalized modeling for individual patients and cohort-based approaches for broader applications. The review concludes by emphasizing the importance of integrating experimental data and clinical validation to enhance the utility of computerized atrial models to improve patient outcomes.

physics.comp-ph

Consensus statement on the credibility assessment of ML predictors

The rapid integration of machine learning (ML) predictors into in silico medicine has revolutionized the estimation of quantities of interest (QIs) that are otherwise challenging to measure directly. However, the credibility of these predictors is critical, especially when they inform high-stakes healthcare decisions. This position paper presents a consensus statement developed by experts within the In Silico World Community of Practice. We outline twelve key statements forming the theoretical foundation for evaluating the credibility of ML predictors, emphasizing the necessity of causal knowledge, rigorous error quantification, and robustness to biases. By comparing ML predictors with biophysical models, we highlight unique challenges associated with implicit causal knowledge and propose strategies to ensure reliability and applicability. Our recommendations aim to guide researchers, developers, and regulators in the rigorous assessment and deployment of ML predictors in clinical and biomedical contexts.

q-bio.QM

Computational modelling of biological systems now and then: revisiting tools and visions from the beginning of the century

Since the turn of the millennium, computational modelling of biological systems has evolved remarkably and sees matured use spanning basic and clinical research. While the topic of the peri-millennial debate about the virtues and limitations of 'reductionism and integrationism' seems less controversial today, a new apparent dichotomy dominates discussions: mechanistic vs. data-driven modelling. In light of this distinction, we provide an overview of recent achievements and new challenges with a focus on the cardiovascular system. Attention has shifted from generating a universal model of the human to either models of individual humans (digital twins) or entire cohorts of models representative of clinical populations to enable in silico clinical trials. Disease-specific parameterisation, inter-individual and intra-individual variability, uncertainty quantification as well as interoperable, standardised, and quality-controlled data are important issues today, which call for open tools, data and metadata standards, as well as strong community interactions. The quantitative, biophysical, and highly controlled approach provided by in silico methods has become an integral part of physiological and medical research. In silico methods have the potential to accelerate future progress also in the fields of integrated multi-physics modelling, multi-scale models, virtual cohort studies, and machine learning beyond what is feasible today. In fact, mechanistic and data-driven modelling can complement each other synergistically and fuel tomorrow's artificial intelligence applications to further our understanding of physiology and disease mechanisms, to generate new hypotheses and assess their plausibility, and thus to contribute to the evolution of preventive, diagnostic, and therapeutic approaches.

q-bio.QM

A Cyclical Fast Iterative Method for Simulating Reentries in Cardiac Electrophysiology Using an Eikonal-Based Model

Background: Computer models for simulating cardiac electrophysiology are valuable tools for research and clinical applications. Traditional reaction-diffusion (RD) models used for these purposes are computationally expensive. While eikonal models offer a faster alternative, they are not well-suited to study cardiac arrhythmias driven by reentrant activity. The present work extends the diffusion-reaction eikonal alternant model (DREAM), incorporating conduction velocity (CV) restitution for simulating complex cardiac arrhythmias. Methods: The DREAM modifies the fast iterative method to model cyclical behavior, dynamic boundary conditions, and frequency-dependent anisotropic CV. Additionally, the model alternates with an approximated RD model, using a detailed ionic model for the reaction term and a triple-Gaussian to approximate the diffusion term. The DREAM and monodomain models were compared, simulating reentries in 2D manifolds with different resolutions. Results: The DREAM produced similar results across all resolutions, while experiments with the monodomain model failed at lower resolutions. CV restitution curves obtained using the DREAM closely approximated those produced by the monodomain simulations. Reentry in 2D slabs yielded similar results in vulnerable window and mean reentry duration for low CV in both models. In the left atrium, most inducing points identified by the DREAM were also present in the high-resolution monodomain model. DREAM's reentry simulations on meshes with an average edge length of 1600$\mu$m were 40x faster than monodomain simulations at 200$\mu$m. Conclusion: This work establishes the mathematical foundation for using the accelerated DREAM simulation method for cardiac electrophysiology. Cardiac research applications are enabled by a publicly available implementation in the openCARP simulator.

physics.med-ph

ECG Feature Importance Rankings: Cardiologists vs. Algorithms

Feature importance methods promise to provide a ranking of features according to importance for a given classification task. A wide range of methods exist but their rankings often disagree and they are inherently difficult to evaluate due to a lack of ground truth beyond synthetic datasets. In this work, we put feature importance methods to the test on real-world data in the domain of cardiology, where we try to distinguish three specific pathologies from healthy subjects based on ECG features comparing to features used in cardiologists' decision rules as ground truth. Some methods generally performed well and others performed poorly, while some methods did well on some but not all of the problems considered.

physics.med-ph

MedalCare-XL: 16,900 healthy and pathological 12 lead ECGs obtained through electrophysiological simulations

Mechanistic cardiac electrophysiology models allow for personalized simulations of the electrical activity in the heart and the ensuing electrocardiogram (ECG) on the body surface. As such, synthetic signals possess known ground truth labels of the underlying disease and can be employed for validation of machine learning ECG analysis tools in addition to clinical signals. Recently, synthetic ECGs were used to enrich sparse clinical data or even replace them completely during training leading to improved performance on real-world clinical test data. We thus generated a novel synthetic database comprising a total of 16,900 12 lead ECGs based on electrophysiological simulations equally distributed into healthy control and 7 pathology classes. The pathological case of myocardial infraction had 6 sub-classes. A comparison of extracted features between the virtual cohort and a publicly available clinical ECG database demonstrated that the synthetic signals represent clinical ECGs for healthy and pathological subpopulations with high fidelity. The ECG database is split into training, validation, and test folds for development and objective assessment of novel machine learning algorithms.

physics.med-ph

Non-invasive Localization of the Ventricular Excitation Origin Without Patient-specific Geometries Using Deep Learning

Ventricular tachycardia (VT) can be one cause of sudden cardiac death affecting 4.25 million persons per year worldwide. A curative treatment is catheter ablation in order to inactivate the abnormally triggering regions. To facilitate and expedite the localization during the ablation procedure, we present two novel localization techniques based on convolutional neural networks (CNNs). In contrast to existing methods, e.g. using ECG imaging, our approaches were designed to be independent of the patient-specific geometries and directly applicable to surface ECG signals, while also delivering a binary transmural position. One method outputs ranked alternative solutions. Results can be visualized either on a generic or patient geometry. The CNNs were trained on a data set containing only simulated data and evaluated both on simulated and clinical test data. On simulated data, the median test error was below 3mm. The median localization error on the clinical data was as low as 32mm. The transmural position was correctly detected in up to 82% of all clinical cases. Using the ranked alternative solutions, the top-3 median error dropped to 20mm on clinical data. These results demonstrate a proof of principle to utilize CNNs to localize the activation source without the intrinsic need of patient-specific geometrical information. Furthermore, delivering multiple solutions can help the physician to find the real activation source amongst more than one possible locations. With further optimization, these methods have a high potential to speed up clinical interventions. Consequently they could decrease procedural risk and improve VT patients' outcomes.

eess.IV

The Impact of Standard Ablation Strategies for Atrial Fibrillation on Cardiovascular Performance in a Four-chamber Heart Model

Atrial fibrillation is one of the most frequent cardiac arrhythmias in the industrialized world and ablation therapy is the method of choice for many patients. However, ablation scars alter the electrophysiological activation and the mechanical behavior of the affected atria. Different ablation strategies with the aim to terminate atrial fibrillation and prevent its recurrence exist but their impact on the hemodynamic performance of the heart has not been investigated thoroughly. In this work, we present a simulation study analyzing five commonly used ablation scar patterns and their combinations in the left atrium regarding their impact on the pumping function of the heart using an electromechanical whole-heart model. We analyzed how the altered atrial activation and increased stiffness due to the ablation scar affect atrial as well as ventricular contraction and relaxation. We found that systolic and diastolic function of the left atrium is impaired by ablation scars and that the reduction of atrial stroke volume of up to 11.43% depends linearly on the amount of inactivated tissue. Consequently, the end-diastolic volume of the left ventricle, and thus stroke volume, was reduced by up to 1.4% and 1.8%, respectively. During ventricular systole, left atrial pressure was increased by up to 20% due to changes in the atrial activation sequence and the stiffening of scar tissue. This study provides biomechanical evidence that atrial ablation has acute effects not only on atrial contraction but also on ventricular pumping function. Our results have the potential to help tailoring ablation strategies towards minimal global hemodynamic impairment.

physics.bio-ph

Comparison of propagation models and forward calculation methods on cellular, tissue and organ scale atrial electrophysiology

Objective: The bidomain model and the finite element method are an established standard to mathematically describe cardiac electrophysiology, but are both suboptimal choices for fast and large-scale simulations due to high computational costs. We investigate to what extent simplified approaches for propagation models (monodomain, reaction-eikonal and eikonal) and forward calculation (boundary element and infinite volume conductor) deliver markedly accelerated, yet physiologically accurate simulation results in atrial electrophysiology. Methods: We compared action potential durations, local activation times (LATs), and electrocardiograms (ECGs) for sinus rhythm simulations on healthy and fibrotically infiltrated atrial models. Results: All simplified model solutions yielded LATs and P waves in accurate accordance with the bidomain results. Only for the eikonal model with pre-computed action potential templates shifted in time to derive transmembrane voltages, repolarization behavior notably deviated from the bidomain results. ECGs calculated with the boundary element method were characterized by correlation coefficients >0.9 compared to the finite element method. The infinite volume conductor method led to lower correlation coefficients caused predominantly by systematic overestimations of P wave amplitudes in the precordial leads. Conclusion: Our results demonstrate that the eikonal model yields accurate LATs and combined with the boundary element method precise ECGs compared to markedly more expensive full bidomain simulations. However, for an accurate representation of atrial repolarization dynamics, diffusion terms must be accounted for in simplified models. Significance: Simulations of atrial LATs and ECGs can be notably accelerated to clinically feasible time frames at high accuracy by resorting to the eikonal and boundary element methods.

physics.med-ph

The openCARP CDE -- Concept for and implementation of a sustainable collaborative development environment for research software

This work describes the setup of an advanced technical infrastructure for collaborative software development (CDE) in large, distributed projects based on GitLab. We present its customization and extension, additional features and processes like code review, continuous automated testing, DevOps practices, and sustainable life-cycle management including long-term preservation and citable publishing of software releases along with relevant metadata. The environment is currently used for developing the open cardiac simulation software openCARP and an evaluation showcases its capability and utility for collaboration and coordination of sizeable heterogeneous teams. As such, it could be a suitable and sustainable infrastructure solution for a wide range of research software projects.

cs.SE

Reducing Line-of-block Artifacts in Cardiac Activation Maps Estimated Using ECG Imaging: A Comparison of Source Models and Estimation Methods

Objective: To investigate cardiac activation maps estimated using electrocardiographic imaging and to find methods reducing line-of-block (LoB) artifacts, while preserving real LoBs. Methods: Body surface potentials were computed for 137 simulated ventricular excitations. Subsequently, the inverse problem was solved to obtain extracellular potentials (EP) and transmembrane voltages (TMV). From these, activation times (AT) were estimated using four methods and compared to the ground truth. This process was evaluated with two cardiac mesh resolutions. Factors contributing to LoB artifacts were identified by analyzing the impact of spatial and temporal smoothing on the morphology of source signals. Results: AT estimation using a spatiotemporal derivative performed better than using a temporal derivative. Compared to deflection-based AT estimation, correlation-based methods were less prone to LoB artifacts but performed worse in identifying real LoBs. Temporal smoothing could eliminate artifacts for TMVs but not for EPs, which could be linked to their temporal morphology. TMVs led to more accurate ATs on the septum than EPs. Mesh resolution had a negligible effect on inverse reconstructions, but small distances were important for cross-correlation-based estimation of AT delays. Conclusion: LoB artifacts are mainly caused by the inherent spatial smoothing effect of the inverse reconstruction. Among the configurations evaluated, only deflection-based AT estimation in combination with TMVs and strong temporal smoothing can prevent LoB artifacts, while preserving real LoBs. Significance: Regions of slow conduction are of considerable clinical interest and LoB artifacts observed in non-invasive ATs can lead to misinterpretations. We addressed this problem by identifying factors causing such artifacts and methods to reduce them.

physics.med-ph

Possible Contexts of Use for In Silico trials methodologies: a consensus-based review

The term "In Silico Trial" indicates the use of computer modelling and simulation to evaluate the safety and efficacy of a medical product, whether a drug, a medical device, a diagnostic product or an advanced therapy medicinal product. Predictive models are positioned as new methodologies for the development and the regulatory evaluation of medical products. New methodologies are qualified by regulators such as FDA and EMA through formal processes, where a first step is the definition of the Context of Use (CoU), which is a concise description of how the new methodology is intended to be used in the development and regulatory assessment process. As In Silico Trials are a disruptively innovative class of new methodologies, it is important to have a list of possible CoUs highlighting potential applications for the development of the relative regulatory science. This review paper presents the result of a consensus process that took place in the InSilicoWorld Community of Practice, an online forum for experts in in silico medicine. The experts involved identified 46 descriptions of possible CoUs which were organised into a candidate taxonomy of nine CoU categories. Examples of 31 CoUs were identified in the available literature; the remaining 15 should, for now, be considered speculative.

physics.bio-ph

A bi-atrial statistical shape model for large-scale in silico studies of human atria: model development and application to ECG simulations

Large-scale electrophysiological simulations to obtain electrocardiograms (ECG) carry the potential to produce extensive datasets for training of machine learning classifiers to, e.g., discriminate between different cardiac pathologies. The adoption of simulations for these purposes is limited due to a lack of ready-to-use models covering atrial anatomical variability. We built a bi-atrial statistical shape model (SSM) of the endocardial wall based on 47 segmented human CT and MRI datasets using Gaussian process morphable models. Generalization, specificity, and compactness metrics were evaluated. The SSM was applied to simulate atrial ECGs in 100 random volumetric instances. The first eigenmode of our SSM reflects a change of the total volume of both atria, the second the asymmetry between left vs. right atrial volume, the third a change in the prominence of the atrial appendages. The SSM is capable of generalizing well to unseen geometries and 95% of the total shape variance is covered by its first 23 eigenvectors. The P waves in the 12-lead ECG of 100 random instances showed a duration of 104ms in accordance with large cohort studies. The novel bi-atrial SSM itself as well as 100 exemplary instances with rule-based augmentation of atrial wall thickness, fiber orientation, inter-atrial bridges and tags for anatomical structures have been made publicly available. The novel, openly available bi-atrial SSM can in future be employed to generate large sets of realistic atrial geometries as a basis for in silico big data approaches.

eess.SP

Cobiveco: Consistent biventricular coordinates for precise and intuitive description of position in the heart -- with MATLAB implementation

Ventricular coordinates are widely used as a versatile tool for various applications that benefit from a description of local position within the heart. However, the practical usefulness of ventricular coordinates is determined by their ability to meet application-specific requirements. For regression-based estimation of biventricular position, for example, a symmetric definition of coordinate directions in both ventricles is important. For the transfer of data between different hearts as another use case, the consistency of coordinate values across different geometries is particularly relevant. To meet these requirements, we compare different approaches to compute coordinates and present Cobiveco, a symmetric, consistent and intuitive biventricular coordinate system that builds upon existing coordinate systems, but overcomes some of their limitations. A novel one-way transfer error is introduced to assess the consistency of the coordinates. Normalized distances along bijective trajectories between two boundaries were found to be superior to solutions of Laplace's equation for defining coordinate values, as they show better linearity in space. Evaluation of transfer and linearity errors on 36 patient geometries revealed a more than 4-fold improvement compared to a state-of-the-art method. Finally, we show two application examples underlining the relevance for cardiac data processing. Cobiveco MATLAB code is available under a permissive open-source license.

eess.SP

Reconstruction of Potassium Concentrations with the ECG on Imbalanced Datasets

End-stage chronic kidney disease (CKD) patients are facing a 30% rise for the risk of lethal cardiac events (LCE) compared to non-CKD patients. At the same time, these patients undergoing dialysis experience shifts in the potassium concentrations. The increased risk of LCE paired with the concentration changes suggest a connection between LCE and concentration disbalances. To prove this link, a continuous monitoring device for the ionic concentrations, e.g. the ECG, is needed. In this work, we want to answer if an optimised signal processing chain can improve the result quantify the influence of a disbalanced training dataset on the final estimation result. The study was performed on a dataset consisting of 12-lead ECGs recorded during dialysis sessions of 32 patients. We selected three features to find a mapping from ECG features to [K+]o: T-wave ascending slope, T-wave descending slope and T-wave amplitude. A polynomial model of 3rd order was used to reconstruct the concentrations from these features. We solved a regularised weighted least squares problem with a weighting matrix dependent on the frequency of each concentration in the dataset (frequent concentration weighted less). By doing so, we tried to generate a model being suitable for the whole range of the concentrations.With weighting, errors are increasing for the whole dataset. For the data partition with [K+]o<5 mmol/l, errors are increasing, for [K+]o$\geq$5 mmol/l, errors are decreasing. However, and apart from the exact reconstruction results, we can conclude that a model being valid for all patients and not only the majority, needs to be learned with a more homogeneous dataset. This can be achieved by leaving out data points or by weighting the errors during the model fitting. With increasing weighting, we increase the performance on the part of the [K+]o that are less frequent which was desired in our case.

eess.SP

An Environment for Sustainable Research Software in Germany and Beyond: Current State, Open Challenges, and Call for Action

Research software has become a central asset in academic research. It optimizes existing and enables new research methods, implements and embeds research knowledge, and constitutes an essential research product in itself. Research software must be sustainable in order to understand, replicate, reproduce, and build upon existing research or conduct new research effectively. In other words, software must be available, discoverable, usable, and adaptable to new needs, both now and in the future. Research software therefore requires an environment that supports sustainability. Hence, a change is needed in the way research software development and maintenance are currently motivated, incentivized, funded, structurally and infrastructurally supported, and legally treated. Failing to do so will threaten the quality and validity of research. In this paper, we identify challenges for research software sustainability in Germany and beyond, in terms of motivation, selection, research software engineering personnel, funding, infrastructure, and legal aspects. Besides researchers, we specifically address political and academic decision-makers to increase awareness of the importance and needs of sustainable research software practices. In particular, we recommend strategies and measures to create an environment for sustainable research software, with the ultimate goal to ensure that software-driven research is valid, reproducible and sustainable, and that software is recognized as a first class citizen in research. This paper is the outcome of two workshops run in Germany in 2019, at deRSE19 - the first International Conference of Research Software Engineers in Germany - and a dedicated DFG-supported follow-up workshop in Berlin.

cs.GL