SearcharxivSearch

arXiv subjects

Ayman Youssef

Publications and source records attributed to Ayman Youssef.

5 recordsLinked to original sources

Readout electronics for SUBMET

A dedicated data acquisition (DAQ) system has been developed for the SUB-Millicharge ExperimenT (SUBMET) at the Japan Proton Accelerator Research Complex (J-PARC), a search for particles carrying a fractional electric charge $Q = \epsilon e$ with $\epsilon$ below $\mathcal{O}(10^{-3})$, hereafter referred to as millicharged particles (mCPs). Because such particles are expected to produce at most a few scintillation photons, the system is optimized for single-photoelectron detection from the photomultiplier tubes (PMTs), combining high-speed waveform digitization with precise timing. To capture eight consecutive proton bunches of the 30 GeV J-PARC beam within a single trigger, the eight channels of the Domino Ring Sampler 4 (DRS4) chip are cascaded in groups of four to form two readout inputs, each sampling 4096 points continuously at 820.5 MHz over an effective time window of 5 us. After calibration, timing differences between channels are within 1 ns on the same DRS4 chip, 2 ns on the same board, and 8 ns across different boards, well within the 30 ns coincidence window of the experiment. The front-end electronics achieve an RMS noise below 0.4 mV. The baseline is deliberately offset upward such that the negative-going pulses span a larger fraction of the digitizer range, improving voltage resolution and dynamic range. A trigger control board aggregates data from multiple readout boards and sustains the data-transfer rate required for beam operation. The measured performance confirms that the DAQ system meets the timing, noise, and throughput requirements of the experiment.

hep-ex

Afterpulse prediction for SUBMET experiment

The SUB-Millicharge ExperimenT (SUBMET) investigates an unexplored parameter space of millicharged particles with mass $m_\chi < $ 1.6 GeV/c$^2$ and charge $Q_\chi < 10^{-3}e$. The detector consists of an Eljen-200 plastic scintillator coupled to a Hamamatsu Photonics R7725 photomultiplier tube (PMT). PMT afterpulses, delayed pulses produced after an energetic pulse, have been observed in the SUBMET readout system, especially following primary pulses with a large area. We present a prediction method for afterpulse rates based on measurable parameters, which reproduces the observed rate with approximately 20\% precision. This approach enables a better understanding of afterpulse contributions and, consequently, improves the reliability of background predictions.

physics.ins-det

Design and Mechanical Integration of Scintillation Modules for SUB-Millicharge ExperimenT (SUBMET)

We present a detailed description of the detector design for the SUB-Millicharge ExperimenT (SUBMET), developed to search for millicharged particles. The experiment probes a largely unexplored region of the charge-mass parameter space, focusing on particles with mass $m_\chi < 1.6~\textrm{GeV}/c^2$ and electric charge $Q < 10^{-3}e$. The detector has been optimized to achieve high sensitivity to interactions of such particles while maintaining effective discrimination against background events. We provide a comprehensive overview of the key detector components, including scintillation modules, photomultiplier tubes, and the mechanical support structure.

physics.ins-det

Small-area Portable Resistive Plate Chambers for Muography

Muography is finding applications in various domains such as volcanology, archaeology, civil engineering, industry, mining, and nuclear waste surveys. To simplify transportation and installation in remote locations after laboratory testing, a fully portable and autonomous muon telescope based on Resistive Plate Chambers (RPCs) is being developed. Two glass-RPC prototypes have been created, sharing the same design goals but with different detector parameters, and comparative studies are ongoing. Drawing from prototype experience, a double-gap RPC with advanced features and improved spatial resolution is constructed. Resistive electrodes are produced manually, and a new data acquisition board is currently undergoing calibration. The results on prototype performance, readout board comparisons and the technical progress on the double-gap RPC are presented.

physics.ins-det

Portable Resistive Plate Chambers for Muography in confined environments

Muography (or muon radiography) is an imaging technique that relies on the use of cosmogenic muons as a free and safe radiation source. It can be applied in various fields such as archaeology, civil engineering, geology, nuclear reactor monitoring, nuclear waste characterization, underground surveys, etc. In such applications, sometimes deploying muon detectors is challenging due to logistics, e.g. in a narrow underground tunnel or mine. Therefore, we are developing muon detectors whose design goals include portability, robustness, autonomy, versatility, and safety. Our portable muon detectors (or ``muoscopes'') are based on Resistive Plate Chambers (RPC), planar detectors that use ionization in a thin gas gap to detect cosmic muons. Prototype RPCs of active area $16 \times 16~cm^2$ and $28 \times 28~cm^2$ were built in our laboratories at Louvain-la-Neuve (UCLouvain) and Ghent (UGent) to test and compare various design options. Benefiting from the experience gained in building and operating these prototypes, we are proceeding towards the development of improved prototypes with more advanced technical layout and readiness. In this paper we provide the status of our performance studies, including the cross-validation of the two types of prototypes in a joint data taking, and an outline of the direction ahead.

physics.ins-det