Searcharxiv⌕ Search

arXiv subjects

Ayrton Almada

Publications and source records attributed to Ayrton Almada.

3 recordsLinked to original sources

Real-Time Dynamic N-1 Screening: Identifying High-Risk Lines and Transformers After Common Faults

Power system operators routinely perform N-1 contingency analysis, yet conventional tools provide limited guidance on which lines or transformers deserve heightened attention during fast post-fault transients. In particular, static screening does not reveal whether (1) the same faulted line repeatedly triggers severe downstream overloads, or (2) a specific transformer emerges as vulnerable across many distinct fault scenarios. This paper introduces a real-time dynamic N-1 screening framework that addresses this gap by estimating, for each counterfactual single-phase transmission fault, the probability of transient overcurrent on critical grid elements. The output is an operator-facing dashboard that ranks (a) faulted lines whose outages most frequently lead to dangerous transformer overloads, and (b) transformers that consistently overload across top-risk scenarios, both of which are actionable indicators for real-time situational awareness. The approach models post-fault electromechanical dynamics using a linear stochastic formulation of the swing equations with short-lived, fault-localized uncertainty, and combines analytic transient evaluation with cross-entropy based importance sampling to efficiently estimate rare but high-impact events. All N-1 contingencies are evaluated in parallel with linear computational complexity. The framework is demonstrated on the IEEE 118-bus system, where it reveals latent high-risk lines and transformers that remain invisible under deterministic dynamic or static N-1 analysis. Results show orders-of-magnitude computational speedup relative to brute-force Monte Carlo, enabling practical deployment within real-time operational cycles.

math.OC↗

Counterfactual Screening of Rare Secondary Overloads in Power Grids with a Stochastic Surrogate for Electromagnetic Transient Simulations

Power-system operators continually ask what would happen if a component failed now. Single-phase-to-ground faults cleared by single-pole tripping and automatic reclosure usually have no lasting consequences. In rare cases, however, the transient excited during the open-phase interval drives distant lines or transformers into overload that persists after the faulted line is restored. We develop a counterfactual screening framework for these secondary overloads, combining a linear stochastic swing surrogate with cross-entropy importance sampling. The surrogate represents the open-phase corridor through an effective coupling factor and localized multiplicative noise, with both parameters learned from electromagnetic-transient (EMT) simulations rather than prescribed. Closed-form propagation of the mean and covariance permits deterministic calibration without Monte Carlo sampling. On the reduced WECC 240-bus system, a globally calibrated model substantially improves finite-time agreement with the EMT electromechanical state. The global models are calibrated at reclosure and tested on disjoint faulted lines under a longer open-phase interval. Line- and operating-state-specific models use additional reclosure data from the assessment lines and provide smaller further gains at the cost of more separate fits. The fitted coupling is lower than the phase-counting baseline, consistent with the direction anticipated by sequence-network analysis. Cross-entropy importance sampling directs computational effort toward contingencies associated with persistent overload and yields rare-event probability estimates together with a map linking initiating faults to the elements they endanger. By separating offline EMT calibration from repeated surrogate evaluation, the method supports probabilistic contingency screening and identifies where detailed high-fidelity assessment is most valuable.

math.OC↗

Real-Time Stochastic Assessment of Dynamic N-1 Grid Contingencies

Power system operators need tools for rapid, real-time counterfactual assessments of grid security under fast-changing conditions. Traditional N-1 contingency analysis lacks dynamic evaluation, especially of frequency swings from common faults. This paper introduces a real-time dashboard framework to screen dynamic contingencies. It assumes: (a) the grid starts in a balanced state; (b) faults can occur randomly on any transmission line, temporarily de-energizing and then reconnecting it within about one second; and (c) contingencies are flagged if post-fault transients cause line flows to exceed safety thresholds. The key contributions are: (1) Overload Indicator: a system-wide metric quantifying integrated N-1 dynamic risk from a given state; (2) Scalable Fault Evaluation Algorithm: a linear-scaling method to assess dynamic fault impacts without brute-force simulations; and (3) Risk Estimation: a Cross Entropy Adaptive Importance Sampling method estimating the likelihood of low probability by high risk events, e.g. associated with potential transformer over-current. We demonstrate the framework on the Israeli transmission power grid (IG).

math.DS↗