SearcharxivSearch

arXiv subjects

Ayusha Abbas

Publications and source records attributed to Ayusha Abbas.

2 recordsLinked to original sources

Training-Free Human-in-the-Loop Anomaly Detection via Memory Bank Correction

Anomaly detectors are hardest to deploy exactly where training data is scarcest: a newly commissioned production line has a handful of verified "golden" samples and no machine-learning engineer on the factory floor. We present a training-free human-in-the-loop framework in which a domain expert corrects a PatchCore detector by direct memory bank editing: no retraining, no gradients, no original training data. A false-positive correction inserts the reviewed image's normal patches through a self-calibrating novelty gate admitting only those beyond the median pool-normal nearest-neighbour distance. From a bank built on only ten golden samples, operator corrections close a median 66% of the gap to an uncorrected fully trained bank (mean 80%, raised by three categories that overshoot parity), significantly improving 12 of 15 MVTec AD categories and harming none: ten samples plus corrections outperform hundreds of samples without them. On already-trained banks the headroom is smaller and concentrated where the bank undersamples normal appearance (gated: toothbrush +0.10, metal nut +0.09, zipper +0.05, screw +0.05), and no category except grid is significantly harmed. Evaluation uses a held-out protocol (20 splits per category, Holm-corrected Wilcoxon), because corrected images entering the bank inflate naive evaluation toward AUROC 1.0 by memorisation. Passive and active querying are statistically indistinguishable; a matched-label-budget control attributes gains to deployment-time label production at 43% of exhaustive-review cost; a defect-memory extension fails decisively. Feedback is simulated from ground truth; live expert trials, where mislabelling is costliest on small banks, remain future work.

cs.LG

Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation

Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.

cs.CV