SearcharxivSearch

arXiv subjects

Aziliz Guezou-Philippe

Publications and source records attributed to Aziliz Guezou-Philippe.

2 recordsLinked to original sources

A Hybrid Physical--Digital Framework for Annotated Fracture Reduction Data Evaluated using Clinically Relevant 3D metrics

A major bottleneck in Computer-Assisted Preoperative Planning (CAPP) for fracture reduction is the limited availability of annotated data. While annotated datasets are now available for evaluating bone fracture segmentation algorithms, there is a notable lack of annotated data for the evaluation of automatic fracture reduction methods. Obtaining precise annotations, which are essential for training and evaluating automatic CAPP algorithm, of the reduced bone therefore remains a critical and underexplored challenge. Existing approaches to assess reduction methods rely either on synthetic fracture simulation which often lacks realism, or on manual virtual reductions, which are complex, time-consuming, operator-dependant and error-prone. To address these limitations, we propose a hybrid physical-digital framework for generating annotated fracture reduction data. Based on fracture CTs, fragments are first 3D printed, physically reduced, fixed and CT scanned to accurately recover transformation matrix applied to each fragment. To quantitatively assess reduction quality, we introduce a reproducible formulation of clinically relevant 3D fracture metrics, including 3D gap, 3D step-off, and total gap area. The framework was evaluated on 11 clinical acetabular fracture cases reduced by two independent operators. Compared to preoperative measurements, the proposed approach achieved mean improvements of 168.85 mm 2 in total gap area, 1.82 mm in 3D gap, and 0.81 mm in 3D step-off. This hybrid physical--digital framework enables the efficient generation of realistic, clinically relevant annotated fracture reduction data that can be used for the development and evaluation of automatic fracture reduction algorithms.

eess.IV

Fully automated workflow for designing patient-specific orthopaedic implants: application to total knee arthroplasty

Background. Osteoarthritis affects about 528 million people worldwide, causing pain and stiffness in the joints. Arthroplasty is commonly performed to treat joint osteoarthritis, reducing pain and improving mobility. Nevertheless, a significant share of patients remain unsatisfied with their surgery. Personalised arthroplasty was introduced to improve surgical outcomes however current solutions require delays, making it difficult to integrate in clinical routine. We propose a fully automated workflow to design patient-specific implants for total knee arthroplasty. Methods. The proposed pipeline first uses artificial neural networks to segment the femur and tibia proximal and distal extremities. Then the full bones are reconstructed using augmented statistical shape models, combining shape and landmarks information. Finally, 77 morphological parameters are computed to design patient-specific implants. The developed workflow has been trained on 91 CT scans and evaluated on 41 CT scans, in terms of accuracy and execution time. Results. The workflow accuracy was $0.4\pm0.2mm$ for segmentation, $1.0\pm0.3mm$ for full bone reconstruction, and $2.2\pm1.5mm$ for anatomical landmarks determination. The custom implants fitted the patients' anatomy with $0.9\pm0.5mm$ accuracy. The whole process from segmentation to implants' design lasted about 15 minutes. Conclusion. The proposed workflow performs a fast and reliable personalisation of knee implants, directly from a CT image without requiring any manual intervention. It allows the establishment of a patient-specific pre-operative planning in a very short time, making it easily available for all patients. Combined with efficient implant manufacturing techniques, this solution could help answer the growing number of arthroplasties while reducing complications and improving patients' satisfaction.

cs.CV