SearcharxivSearch

arXiv subjects

B. Biskup

Publications and source records attributed to B. Biskup.

9 recordsLinked to original sources

Experimental observation of proton bunch modulation in a plasma, at varying plasma densities

We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the proton bunch which creates a relativistic ionization front within the bunch. We show by varying the plasma density over one order of magnitude that the modulation period scales with the expected dependence on the plasma density.

physics.acc-ph

A magnetic spectrometer to measure electron bunches accelerated at AWAKE

A magnetic spectrometer has been developed for the AWAKE experiment at CERN in order to measure the energy distribution of bunches of electrons accelerated in wakefields generated by proton bunches in plasma. AWAKE is a proof-of-principle experiment for proton-driven plasma wakefield acceleration, using proton bunches from the SPS. Electron bunches are accelerated to $\mathcal{O}$(1 GeV) in a rubidium plasma cell and then separated from the proton bunches via a dipole magnet. The dipole magnet also induces an energy-dependent spatial horizontal spread on the electron bunch which then impacts on a scintillator screen. The scintillation photons emitted are transported via three highly-reflective mirrors to an intensified CCD camera, housed in a dark room, which passes the images to the CERN controls system for storage and further analysis. Given the known magnetic field and determination of the efficiencies of the system, the spatial spread of the scintillation photons can be converted to an electron energy distribution. A lamp attached on a rail in front of the scintillator is used to calibrate the optical system, with calibration of the scintillator screen's response to electrons carried out at the CLEAR facility at CERN. In this article, the design of the AWAKE spectrometer is presented, along with the calibrations carried out and expected performance such that the energy distribution of accelerated electrons can be measured.

physics.ins-det

AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch

AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %

physics.plasm-ph

The Two-Screen Measurement Setup to Indirectly Measure Proton Beam Self-Modulation in AWAKE

The goal of the first phase of the AWAKE \cite{AWAKE1,AWAKE2} experiment at CERN is to measure the self-modulation \cite{SMI} of the $σ_z = 12\,\rm{cm}$ long SPS proton bunch into microbunches after traversing $10\,\rm{m}$ of plasma with a plasma density of $n_{pe}=7\times10^{14}\,\rm{electrons/cm}^3$. The two screen measurement setup \cite{Turner2016} is a proton beam diagnostic that can indirectly prove the successful development of the self-modulation of the proton beam by imaging protons that got defocused by the transverse plasma wakefields after passing through the plasma, at two locations downstream the end of the plasma. This article describes the design and realization of the two screen measurement setup integrated in the AWAKE experiment. We discuss the performance and background response of the system based on measurements performed with an unmodulated Gaussian SPS proton bunch during the AWAKE beam commissioning in September and October 2016. We show that the system is fully commissioned and adapted to eventually image the full profile of a self-modulated SPS proton bunch in a single shot measurement during the first phase of the AWAKE experiment.

physics.acc-ph

Indirect Self-Modulation Instability Measurement Concept for the AWAKE Proton Beam

AWAKE, the Advanced Proton-Driven Plasma Wakefield Acceleration Experiment, is a proof-of-principle R&D experiment at CERN using a 400 GeV/c proton beam from the CERN SPS (longitudinal beam size sigma_z = 12 cm) which will be sent into a 10 m long plasma section with a nominal density of approx. 7x10^14 atoms/cm3 (plasma wavelength lambda_p = 1.2mm). In this paper we show that by measuring the time integrated transverse profile of the proton bunch at two locations downstream of the AWAKE plasma, information about the occurrence of the self-modulation instability (SMI) can be inferred. In particular we show that measuring defocused protons with an angle of 1 mrad corresponds to having electric fields in the order of GV/m and fully developed self-modulation of the proton bunch. Additionally, by measuring the defocused beam edge of the self-modulated bunch, information about the growth rate of the instability can be extracted. If hosing instability occurs, it could be detected by measuring a non-uniform defocused beam shape with changing radius. Using a 1 mm thick Chromox scintillation screen for imaging of the self-modulated proton bunch, an edge resolution of 0.6 mm and hence a SMI saturation point resolution of 1.2 m can be achieved.

physics.plasm-ph

AWAKE, The Advanced Proton Driven Plasma Wakefield Acceleration Experiment at CERN

The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton beam bunches from the SPS. The first experiments will focus on the self-modulation instability of the long (rms ~12 cm) proton bunch in the plasma. These experiments are planned for the end of 2016. Later, in 2017/2018, low energy (~15 MeV) electrons will be externally injected to sample the wakefields and be accelerated beyond 1 GeV. The main goals of the experiment will be summarized. A summary of the AWAKE design and construction status will be presented.

physics.acc-ph

Path to AWAKE: Evolution of the concept

This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experimental design, where the critical issues that arose and their solutions are described. We conclude with the design of the experiment as it is being realized at CERN and some words on the future outlook. A summary of the AWAKE design and construction status as presented in this conference is given in [1].

physics.plasm-ph

The LBNO long-baseline oscillation sensitivities with two conventional neutrino beams at different baselines

The proposed Long Baseline Neutrino Observatory (LBNO) initially consists of $\sim 20$ kton liquid double phase TPC complemented by a magnetised iron calorimeter, to be installed at the Pyhäsalmi mine, at a distance of 2300 km from CERN. The conventional neutrino beam is produced by 400 GeV protons accelerated at the SPS accelerator delivering 700 kW of power. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the $L/E$ behaviour, and distinguishing effects arising from $δ_{CP}$ and matter. In this paper we show how this comprehensive physics case can be further enhanced and complemented if a neutrino beam produced at the Protvino IHEP accelerator complex, at a distance of 1160 km, and with modest power of 450 kW is aimed towards the same far detectors. We show that the coupling of two independent sub-MW conventional neutrino and antineutrino beams at different baselines from CERN and Protvino will allow to measure CP violation in the leptonic sector at a confidence level of at least $3σ$ for 50\% of the true values of $δ_{CP}$ with a 20 kton detector. With a far detector of 70 kton, the combination allows a $3σ$ sensitivity for 75\% of the true values of $δ_{CP}$ after 10 years of running. Running two independent neutrino beams, each at a power below 1 MW, is more within today's state of the art than the long-term operation of a new single high-energy multi-MW facility, which has several technical challenges and will likely require a learning curve.

hep-ph

Optimised sensitivity to leptonic CP violation from spectral information: the LBNO case at 2300 km baseline

One of the main goals of the Long Baseline Neutrino Observatory (LBNO) is to study the $L/E$ behaviour (spectral information) of the electron neutrino and antineutrino appearance probabilities, in order to determine the unknown CP-violation phase $δ_{CP}$ and discover CP-violation in the leptonic sector. The result is based on the measurement of the appearance probabilities in a broad range of energies, covering t he 1st and 2nd oscillation maxima, at a very long baseline of 2300 km. The sensitivity of the experiment can be maximised by optimising the energy spectra of the neutrino and anti-neutrino fluxes. Such an optimisation requires exploring an extended range of parameters describing in details the geometries and properties of the primary protons, hadron target and focusing elements in the neutrino beam line. In this paper we present a numerical solution that leads to an optimised energy spectra and study its impact on the sensitivity of LBNO to discover leptonic CP violation. In the optimised flux both 1st and 2nd oscillation maxima play an important role in the CP sensitivity. The studies also show that this configuration is less sensitive to systematic errors (e.g. on the total event rates) than an experiment which mainly relies on the neutrino-antineutrino asymmetry at the 1st maximum to determine the existence of CP-violation.

hep-ph