SearcharxivSearch

arXiv subjects

B. Buonomo

Publications and source records attributed to B. Buonomo.

At least 19 recordsLinked to original sources

DAΦNE -2023/24 Activity report

The DAΦNE operations during the last year have been devoted to deliver a statistically significant data sample to perform the first-ever measurement of kaonic deuterium X-ray transitions to the fundamental level. Operations for the SIDDHARTA-2 detector using a deuterium gas target started officially on the second half of May 2023, and have been organized in several runs here described.

physics.acc-ph

Characterization of the PADME positron beam for the X17 measurement

This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within $\sim$ 1-2 MeV$/c$, a relative beam energy spread below 0.25\%, and an absolute precision in the intensity of the beam at the level of 2\% percent.

hep-ex

TEX (TEst stand for X-band) at LNF

TEX facility if commissioned for high power testing to characterize accelerating structures and validate them for the operation on future particle accelerators for medical, industrial and research applications. At this aim, TEX is directly involved in the LNF leading project EuPRAXIA@SPARC_Lab. The brief description of the facility and its status and prospective will be provided.

physics.acc-ph

The Frascati Beam Test Facility

From 2004 the Frascati Beam Test Facility (BTF) in the DAFNE accelerator complex provides to the external user up to 1E10 electrons per bunch or up to 10E9 positrons per bunch to develop their detectors. After an upgrade program terminated in 2020 of the beam test facility a description of the status and available beam lines will be done.

physics.acc-ph

Stepping closer to pulsed single microwave photon detectors for axions search

Axions detection requires the ultimate sensitivity down to the single photon limit. In the microwave region this corresponds to energies in the yJ range. This extreme sensitivity has to be combined with an extremely low dark count rate, since the probability of axions conversion into microwave photons is supposed to be very low. To face this complicated task, we followed two promising approaches that both rely on the use of superconducting devices based on the Josephson effect. The first one is to use a single Josephson junction (JJ) as a switching detector (i.e. exploiting the superconducting to normal state transition in presence of microwave photons). We designed a device composed of a coplanar waveguide terminated on a current biased Josephson junction. We tested its efficiency to pulsed (pulse duration 10 ns) microwave signals, since this configuration is closer to an actual axions search experiment. We show how our device is able to reach detection capability of the order of 10 photons with frequency 8 GHz. The second approach is based on an intrinsically quantum device formed by two resonators coupled only via a superconducting qubit network (SQN). This approach relies on quantum nondemolition measurements of the resonator photons. We show that injecting RF power into the resonator, the frequency position of the resonant drop in the transmission coefficient (S21) can be modulated up to 4 MHz. We anticipate that, once optimized, both the devices have the potential to reach single photon sensitivity.

quant-ph

Design, optimization and experimental characterization of RF injectors for high brightness electron beams and plasma acceleration

In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains information about the improvements, that were introduced into the new photo-injector design from the machine maintenance point of view, and the benefits, that we gained by using the new technique to assemble the gun itself.

physics.acc-ph

Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector

The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.

hep-ex

Commissioning of the PADME experiment with a positron beam

The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target. This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.

physics.ins-det

The PADME beam line Monte Carlo simulation

The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) of the INFN Laboratory of Frascati is designed to search for invisible decays of dark sector particles produced in electron-positron annihilation events with a positron beam and a thin fixed target, by measuring the missing mass of single-photon final states. The presence of backgrounds originating from beam halo particles can significantly reduce the sensitivity of the experiment. To thoroughly understand the origin of the beam background contribution, a detailed Geant4-based Monte Carlo simulation has been developed, containing a full description of the detector together with the beam line and its optical elements. This simulation allows the full interactions of each particle to be described, both during beam line transport and during detection, a possibility which represents an innovative way to obtain reliable background predictions

hep-ex

Performance of scintillating tiles with direct silicon-photomultiplier (SiPM) readout for application to large area detectors

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati and several test stands. The results obtained with different configurations are presented. A time resolution of the order of 300 ps, a light yield of more than 230 photo-electrons, and an efficiency better than 99.8 $\%$ are obtained with $\sim 225$ cm$^2$ large area tiles. This technology is suitable for a wide range of applications in high-energy physics, in particular for large area muon and timing detectors.

physics.ins-det

Characterisation and performance of the PADME electromagnetic calorimeter

The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $γ$. The missing four-momentum carried away by the $A'$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADME's electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.

physics.ins-det

Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter

The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow γA'$, where the $A'$ escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF$_2$ crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/$\sqrt{E}$ with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF$_2$ crystal for higher-energy applications, which has potentially attractive features.

physics.ins-det

The AMY (Air Microwave Yield) experiment to measure the GHz emission from air shower plasma

The aim of the Air Microwave Yield (AMY) experiment is to investigate the Molecular Bremsstrahlung Radiation (MBR) emitted from an electron beam induced air-shower. The measurements have been performed with a 510 MeV electron beam at the Beam Test Facility (BTF) of Frascati INFN National Laboratories in a wide frequency range between 1 and 20 GHz. We present the experimental apparatus and the first results of the measurements. Contrary to what have been reported in a previous similar experiment~\cite{Gorham-SLAC}, we have found that the intensity of the emission is strongly influenced by the particular time structure of the accelerator beam. This makes very difficult the interpretation of the emission process and a realistic extrapolation of the emission yield to the plasma generated during the development of an atmospheric shower.

astro-ph.IM

Calibration of AGILE-GRID with on-ground data and Monte Carlo simulations

AGILE is a mission of the Italian Space Agency (ASI) Scientific Program dedicated to gamma-ray astrophysics, operating in a low Earth orbit since April 23, 2007. It is designed to be a very light and compact instrument, capable of simultaneously detecting and imaging photons in the 18 keV to 60 keV X-ray energy band and in the 30 MeV{50 GeV gamma-ray energy with a good angular resolution (< 1 deg at 1 GeV). The core of the instrument is the Silicon Tracker complemented with a CsI calorimeter and a AntiCoincidence system forming the Gamma Ray Imaging Detector (GRID). Before launch, the GRID needed on-ground calibration with a tagged gamma-ray beam to estimate its performance and validate the Monte Carlo simulation. The GRID was calibrated using a tagged gamma-ray beam with energy up to 500 MeV at the Beam Test Facilities at the INFN Laboratori Nazionali di Frascati. These data are used to validate a GEANT3 based simulation by comparing the data and the Monte Carlo simulation by measuring the angular and energy resolutions. The GRID angular and energy resolutions obtained using the beam agree well with the Monte Carlo simulation. Therefore the simulation can be used to simulate the same performance on-light with high reliability.

astro-ph.IM

EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF

On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.

physics.acc-ph

Preliminary RF design of an X-band linac for the EuPRAXIA@SPARC_LAB project

In the framework of the upgrade of the SPARC_LAB facility at INFN-LNF, named EuPRAXIA@SPARC_LAB, a high gradient linac is foreseen. One of the most suitable options is to realize it in X-band. A preliminary design study of both accelerating structures and power distribution system has been performed. It is based on 0.5 m long travelling wave (TW) accelerating structures operating in the 2π/3 mode and fed by klystrons and pulse compressor systems. The main parameters of the structures and linac are presented with the basic RF linac layout.

physics.acc-ph

Performance of the PADME calorimeter prototype at the DA$Φ$NE BTF

The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) aims at searching for invisible decays of the dark photon by measuring the final state missing mass in the process $e^+e^- \to γ+ A'$, with $A'$ undetected. The measurement requires the determination of the 4-momentum of the recoil photon, performed using a homogeneous, highly segmented BGO crystals calorimeter. We report the results of the test of a 5$\times$5 crystals prototype performed with an electron beam at the BTF in July 2016.

physics.ins-det

Analysis of a mosquito-borne epidemic model with vector stages and saturating forces of infection

We study a mosquito-borne epidemic model where the vector population is distinct in aquatic and adult stages and a saturating effect of disease transmission is assumed to ocurr when the number of infectious (humans and mosquitoes) becomes large enough. Several techniques, including center manifold analysis and sensitivity analysis, have been used to reveal relevant features of the model dynamics. We determine the existence of stability-instability thresholds and the individual role played in such thresholds by the model parameters.

q-bio.PE