Searcharxiv⌕ Search

arXiv subjects

B. Cabrera

Publications and source records attributed to B. Cabrera.

66 records · Page 4Linked to original sources

Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments

The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.

astro-ph.CO↗

Search for inelastic dark matter with the CDMS II experiment

Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.

astro-ph.CO↗

Results from a Low-Energy Analysis of the CDMS II Germanium Data

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

astro-ph.CO↗

Low-threshold analysis of CDMS shallow-site data

Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments' data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c^2 and 4 GeV/c^2.

astro-ph.CO↗

Oblique propagation of electrons in crystals of germanium and silicon at sub-Kelvin temperature in low electric fields

We show that oblique propagation of electrons in crystals of Ge and Si, where the electron velocity does not follow the electric field even on average, can be explained using standard anisotropic theory for indirect gap semiconductors. These effects are pronounced at temperatures below ~1K and for electric fields below ~5V/cm because inter-valley transitions are energetically suppressed forcing electrons to remain in the same band valley throughout their motion and the valleys to separate in position space. To model, we start with an isotropic approximation which incorporates the average properties of the crystals with one phonon mode, and include the ellipsoidal electron valleys by transforming into a momentum space where constant energy surfaces are spheres. We include comparisons of simulated versus measured drift velocities for holes and electrons, and explain the large discrepancy between electrons and holes for shared events in adjacent electrodes.

astro-ph.IM↗

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2 - 8.5 keV. We find no significant excess in the counting rate above background, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA by 8.9$σ$. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z^2 scaling. With this assumption the observed rate in DAMA differs from the upper limit in CDMS by 6.8$σ$. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of ~2 less than observed by DAMA, constraining some possible interpretations of this modulation.

astro-ph.GA↗

A New Apparatus for Detecting Micron-Scale Deviations from Newtonian Gravity

We describe the design and construction of a new apparatus for detecting or constraining deviations from Newtonian gravity at short length scales. The apparatus consists of a new type of probe with rotary mass actuation and cantilever-based force detection which is used to directly measure the force between two micromachined masses separated by tens of microns. We present the first data from the experiment, and discuss the prospects of more precisely constraining or detecting non-Newtonian effects using this probe. Currently, the sensitivity to attractive mass-dependent forces is equal to the best existing limits at length scales near 5 microns. No non-Newtonian effects are detected at that level.

gr-qc↗

An X-ray Galaxy Cluster Survey for Investigations of Dark Energy

The amount and nature of dark energy (DE) can be tightly constrained by measuring the spatial correlation features and evolution of a sample of ~ 100,000 galaxy clusters over the redshift range 0<z < 1.5. Such an X-ray survey will discover all collapsed structures with mass above 3.5e14 solar masss at redshifts z<2 (i.e. the full range where such objects are expected) in the high Galactic latitude sky. Above this mass threshold the tight correlations between X-ray observables and mass allow direct interpretation of the data. We describe the constraints on Dark Energy that can be inferred from such a survey, using powerful self-calibration techniques to relate the X-ray observables (luminosity and temperature) to the underlying mass.

astro-ph↗

Beyond the CDMS-II Dark Matter Search: SuperCDMS

Presently the CDMS-II collaboration's Weakly Interacting Massive Particle (WIMP) search at the Soudan Underground Laboratory sets the most stringent exclusion limits of any WIMP cold dark matter direct-detection experiment. To extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46} - 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very deep site. One promising site is the recently approved SNOLab facility in Canada. In this paper we will present our overall plan, identify primary issues, and set the goals that need to be met prior to embarking upon each phase of SuperCDMS.

astro-ph↗

UV-IR Science Prospects with TES Imaging Arrays

We are developing photon-counting cameras employing cryogenic arrays of energy-resolving TES (Transition Edge Sensor) pixels. These are being tested in ground-based instruments, but will have their greatest impact when employed on space platforms, where they can cover the 10micrometer-100nm range with high time- and moderate energy- resolution. Here we summarize briefly existing device performance, current directions in array camera development and anticipated capabilities.

astro-ph↗

Phase-resolved Crab Studies with a Cryogenic TES Spectrophotometer

We are developing time- and energy-resolved near-IR/optical/UV photon detectors based on sharp superconducting-normal transition edges in thin films. We report observations of the Crab pulsar made during prototype testing at the McDonald 2.7m telescope with a fiber-coupled transition-edge sensor (TES) system. These data show substantial (d[alpha]~0.3), rapid variations in the spectral index through the pulse profile, with a strong phase-varying IR break across our energy band. These variations correlate with X-ray spectral variations, but no single synchrotron population can account for the full Spectral Energy Distribution (SED). We also describe test spectrophotopolarimetry observations probing the energy dependence of the polarization sweep; this may provide a new key to understanding the radiating particle population.

astro-ph↗

First Astronomical Application of a Cryogenic TES Spectrophotometer

We report on the first astronomical observations with a photon counting pixel detector that provides arrival time- (delta t = 100ns) and energy- (delta E_gamma < 0.15eV) resolved measurements from the near IR through the near UV. Our test observations were performed by coupling this Transition Edge Sensor (TES) device to a 0.6m telescope; we have obtained the first simultaneous optical near-IR phase-resolved spectra of the Crab pulsar. A varying infrared turnover gives evidence of self-absorption in the pulsar plasma. The potential of such detectors in imaging arrays from a space platform are briefly described.

astro-ph↗