SearcharxivSearch

arXiv subjects

B. Carniol

Publications and source records attributed to B. Carniol.

4 recordsLinked to original sources

Low-energy neutron cross-talk between organic scintillator detectors

A series of measurements have been performed with low-energy monoenergetic neutrons to characterise cross-talk between two organic scintillator detectors. Cross-talk time-of-flight spectra and probabilities were determined for neutron energies from 1.4 to 15.5 MeV and effective scattering angles ranging from $\sim$50{\deg} to $\sim$100{\deg}. Monte-Carlo simulations incorporating both the active and inactive materials making up the detectors showed reasonable agreement with the measurements. Whilst the time-of-flight spectra were very well reproduced, the cross-talk probabilities were only in approximate agreement with the measurements, with the most significant discrepancies ($\sim$40 %) occurring at the lowest energies. The neutron interaction processes producing cross-talk at the energies explored here are discussed in the light of these results.

physics.ins-det

COMET Phase-I Technical Design Report

The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus ($\mu-e$ conversion, $\mu^- N \to e^- N$); a lepton flavor violating process. The experimental sensitivity goal for this process in the Phase-I experiment is $3.1\times10^{-15}$, or 90 % upper limit of branching ratio of $7\times 10^{-15}$, which is a factor of 100 improvement over the existing limit. The expected number of background events is 0.032. To achieve the target sensitivity and background level, the 3.2 kW 8 GeV proton beam from J-PARC will be used. Two types of detectors, CyDet and StrECAL, will be used for detecting the \mue conversion events, and for measuring the beam-related background events in view of the Phase-II experiment, respectively. Results from simulation on signal and background estimations are also described.

physics.ins-det

High Precision Measurement of the $^{19}$Ne Half-life using real-time digital acquisition

The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569\pm0.0019_{(stat)}\pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {\it et al.}, Phys. Rev. Lett. {\bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.

nucl-ex

Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL

Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one s own sample analysis to state of the art dosimetric references.

physics.med-ph