SearcharxivSearch

arXiv subjects

B. Gobbo

Publications and source records attributed to B. Gobbo.

At least 19 recordsLinked to original sources

Radiation damage study of Belle II silicon strip sensors with 90 MeV electron irradiation

The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor properties induced by radiation damage in the semiconductor bulk. Electrons around this energy are a major source of beam-induced background during Belle II operation. We discuss observed changes in full depletion voltage, sensor leakage current, noise, and charge collection. The sensor bulk type inverts at an equivalent 1-MeV-neutron fluence of $6.0\times 10^{12}~{\rm n}_{\rm eq}/{\rm cm^2}$. The leakage current increases proportionally to the radiation dose. We determine a damage constant of $3.9 \times 10^{-17}$ A/cm at 17 C$^\circ$ immediately after irradiation, which drops significantly to approximately 40% of the initial value in 200 hours, then stabilizes to approximately 30% of the initial value in 1000 hours. We measure sensor noise and signal charge for a sensor irradiated with the equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. Noise increases by approximately 44% after irradiation, while signal charge does not change significantly when a sufficiently high bias voltage is applied.

physics.ins-det

Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II

In 2024, the Belle II experiment resumed data taking after the Long Shutdown 1, which was required to install a two-layer pixel detector and upgrade accelerator components. We describe the challenges of this shutdown and the operational experience thereafter. With new data, the silicon-strip vertex detector (SVD) confirmed the high hit efficiency, the large signal-to-noise ratio, and the excellent cluster position resolution. In the coming years, the SuperKEKB peak luminosity is expected to increase to its target value, resulting in a larger SVD occupancy caused by beam background. Considerable efforts have been made to improve SVD reconstruction software by exploiting the excellent SVD hit-time resolution to determine the collision time and reject off-time particle hits. A novel procedure to group SVD hits event-by-event, based on their time, has been developed using the grouping information during reconstruction, significantly reducing the fake rate while preserving the tracking efficiency. The front-end chip (APV25) is operated in the multi-peak mode, which reads six samples. A 3/6-mixed acquisition mode, based on the timing precision of the trigger, reduces background occupancy, trigger dead-time, and data size. Studies of the radiation damage show that the SVD performance will not seriously degrade during the lifetime of the detector, despite moderate radiation-induced increases in sensor current and strip noise.

physics.ins-det

The Belle II Detector Upgrades Framework Conceptual Design Report

We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.

hep-ex

Silicon Vertex Detector of the Belle II Experiment

The silicon vertex detector (SVD) is installed at the heart of the Belle II experiment, taking data at the high-luminosity $B$-Factory SuperKEKB since 2019. The detector has shown a stable and above-99\% hit efficiency, with a large signal-to-noise in all sensors since the beginning of data taking. Cluster position and time resolution have been measured with 2020 and 2022 data and show excellent performance and stability. The effect of radiation damage is visible, but not affecting the performance. As the luminosity increases, higher machine backgrounds are expected and the excellent hit-time information in SVD can be exploited for background rejection. In particular, we have recently developed a novel procedure to select hits by grouping them event-by-event based on their time. This new procedure allows a significant reduction of the fake rate, while preserving the tracking efficiency, and it has therefore replaced the previous cut-based procedure. We have developed a method that uses the SVD hits to estimate the track time (previously unavailable) and the collision time. It has a similar precision to the estimate based on the drift chamber but its execution time is three orders of magnitude smaller, allowing a faster online reconstruction that is crucial in a high luminosity regime. The track time is a powerful information provided to analysis that allows, together with the above-mention grouping selection, to raise the occupancy limit above that expected at nominal luminosity, leaving room for a safety factor. Finally, in June 2022 the data taking of the Belle II experiment was stopped to install a new two-layer DEPFET detector (PXD) and upgrade components of the accelerator. The whole silicon tracker (PXD+SVD) has been extracted from Belle II, the new PXD installed, the detector closed and commissioned. We briefly describe the SVD results of this upgrade.

hep-ex

Observation of $e^+e^-\toωχ_{bJ}(1P)$ and search for $X_b \to ωΥ(1S)$ at $\sqrt{s}$ near 10.75 GeV

We study the processes $e^+e^-\toωχ_{bJ}(1P)$ ($J$ = 0, 1, or 2) using samples at center-of-mass energies $\sqrt{s}$ = 10.701, 10.745, and 10.805 GeV, corresponding to 1.6, 9.8, and 4.7 fb$^{-1}$ of integrated luminosity, respectively. These data were collected with the Belle II detector during special operations of the SuperKEKB collider above the $Υ(4S)$ resonance. We report the first observation of $ωχ_{bJ}(1P)$ signals at $\sqrt{s}$ = 10.745 GeV. By combining Belle II data with Belle results at $\sqrt{s}$ = 10.867 GeV, we find energy dependencies of the Born cross sections for $e^+e^-\to ωχ_{b1,b2}(1P)$ to be consistent with the shape of the $Υ(10753)$ state. These data indicate that the internal structures of the $Υ(10753)$ and $Υ(10860)$ states may differ. Including data at $\sqrt{s}$ = 10.653 GeV, we also search for the bottomonium equivalent of the $X(3872)$ state decaying into $ωΥ(1S)$. No significant signal is observed for masses between 10.45 and 10.65 GeV/$c^2$.

hep-ex

Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.

physics.ins-det

The Silicon Vertex Detector of the Belle II Experiment

In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.

physics.ins-det

Search for Axion-Like Particles produced in $e^+e^-$ collisions at Belle II

We present a search for the direct production of a light pseudoscalar $a$ decaying into two photons with the Belle II detector at the SuperKEKB collider. We search for the process ${e^+e^-\toγa, a \toγγ}$ in the mass range ${0.2} \,< m_a < {9.7}\,{\text{GeV/$c$}^2}$ using data corresponding to an integrated luminosity of $(445\pm 3)\,\text{pb}^{-1}$. Light pseudoscalars interacting predominantly with standard model gauge bosons (so-called axion-like particles or ALPs) are frequently postulated in extensions of the standard model. We find no evidence for ALPs and set 95% confidence level upper limits on the coupling strength $g_{aγγ}$ of ALPs to photons at the level of $10^{-3}\,{\text{GeV}^{-1}}$. The limits are the most restrictive to date for $0.2\,<\,m_a\,<\,1\,{\text{GeV/$c$}^2}$.

hep-ex

Search for an invisibly decaying $Z^{\prime}$ boson at Belle II in $e^+ e^- \to μ^+ μ^- (e^{\pm} μ^{\mp})$ plus missing energy final states

Theories beyond the standard model often predict the existence of an additional neutral boson, the $Z^{\prime}$. Using data collected by the Belle II experiment during 2018 at the SuperKEKB collider, we perform the first searches for the invisible decay of a $Z^{\prime}$ in the process $e^+ e^- \to μ^+ μ^- Z^{\prime}$ and of a lepton-flavor-violating $Z^{\prime}$ in $e^+ e^- \to e^{\pm} μ^{\mp} Z^{\prime}$. We do not find any excess of events and set 90\% credibility level upper limits on the cross sections of these processes. We translate the former, in the framework of an $L_μ-L_τ$ theory, into upper limits on the $Z^{\prime}$ coupling constant at the level of $5 \times 10^{-2}$ -- $1$ $M_{Z^\prime}\leq 6$ GeV/$c^2$.

hep-ex

Direct measurements of the properties of Thick-GEM reflective photocathodes

In the context of the development of novel Thick GEM based detectors of single photons, the high resolution optical system, nicknamed Leopard, providing a detailed surface scanning of the Thick GEM electron multipliers, has been used for a set of systematic measurements of key Thick GEM properties. These results are reported and discussed. They confirm by direct observation Thick GEM properties previously inferred by indirect measurements and answer to relevant questions related to the use of Thick GEMs as photocathode substrates in novel gaseous photon detectors.

physics.ins-det

The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1

The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MicroMegas anode is segmented into pads individually biased with positive voltage while the micromesh is grounded. In total, there are about ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels, where appropriate correlations among the applied voltages are required for the correct operation of the detectors. Therefore, a robust control system is mandatory, implemented by a custom designed software package, while commercial power supply units are used. This sophisticated control system allows to protect the detectors against errors by the operator, to monitor and log voltages and currents at 1 Hz rate, and automatically react to detector misbehaviour. In addition, a voltage compensation system has been developed to automatically adjust the biasing voltage according to environmental pressure and temperature variations, to achieve constant gain over time. This development answers to a more general need. In fact, voltage compensation is always a requirement for the stability of gaseous detectors and its need is enhanced in multi-layer ones. In this paper, the HV system and its performance are described in details, as well as the stability of the novel MPGD-based photon detectors during the physics data taking at COMPASS.

physics.ins-det

The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1

The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.

physics.ins-det

RHIP, a Radio-controlled High-Voltage Insulated Picoammeter and its usage in studying ion backflow in MPGD-based photon detectors

A picoammeter system has been developed and engineering. It consists in a current-voltage converter, based on an operational amplifier with very low input current, a high precision ADC, a radio controlled data acquisition unit and the computer-based control, visualization and storage. The precision is of the order of a tenth of picoampers and it can measure currents between electrodes at potentials up to 8 kV. The system is battery powered and a number of strategies have been implemented to limit the power consumption. The system is designed for multichannel applications, up to 256 parallel channels. The overall implementation is cost-effective to make the availability of multichannel setups easily affordable. The design, implementation and performance of the picoammeter system are described in detail as well as a an application: the measurement of ion backflow in MPGD-based photon detectors.

physics.ins-det

The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1

The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at positive voltage, while the micromesh is grounded. In total, there are ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels. Commercial power supply units are used. The original elements of the power supply system are the architecture of the voltage distribution net, the compensation, by voltage adjustment, of the effects of pressure and temperature variation affecting the detector gain and a sophisticated control software, which allows to protect the detectors against errors by the operator, to monitor and log voltages and current at 1 Hz rate and to automatically react to detector misbehaviors. The HV system and its performance are described in detail as well as the electrical stability of the detector during the operation at COMPASS.

physics.ins-det

Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors

A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.

physics.ins-det

Novel MPGD based Detectors of Single Photons in COMPASS RICH-1

COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.

physics.ins-det

Measurement of the charged-pion polarisability

The COMPASS collaboration at CERN has investigated pion Compton scattering, $π^-γ\rightarrow π^-γ$, at centre-of-mass energy below 3.5 pion masses. The process is embedded in the reaction $π^-\mathrm{Ni}\rightarrowπ^-γ\;\mathrm{Ni}$, which is initiated by 190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, $Q^2<0.0015$\,(GeV/$c$)$^2$. From a sample of 63\,000 events the pion electric polarisability is determined to be $α_π =\ (\,2.0\ \pm\ 0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times 10^{-4}\,\mbox{fm}^3$ under the assumption $α_π=-β_π$, which relates the electric and magnetic dipole polarisabilities. It is the most precise measurement of this fundamental low-energy parameter of strong interaction, that has been addressed since long by various methods with conflicting outcomes. While this result is in tension with previous dedicated measurements, it is found in agreement with the expectation from chiral perturbation theory. An additional measurement replacing pions by muons, for which the cross-section behavior is unambigiously known, was performed for an independent estimate of the systematic uncertainty.

hep-ex

The COMPASS Setup for Physics with Hadron Beams

The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.

physics.ins-det