SearcharxivSearch

arXiv subjects

B. Gyüre

Publications and source records attributed to B. Gyüre.

3 recordsLinked to original sources

An optically detected magnetic resonance spectrometer with tunable laser excitation and wavelength resolved infrared detection

We present the development and performance of an optically detected magnetic resonance (ODMR) spectrometer. The spectrometer represents advances over similar instruments in three areas: i) the exciting light is a tunable laser source which covers much of the visible light range, ii) the optical signal is analyzed with a spectrograph, iii) the emitted light is detected in the near-infrared domain. The need to perform ODMR experiments on single-walled carbon nanotubes motivated the present development and we demonstrate the utility of the spectrometer on this material. The performance of the spectrometer is critically compared to similar instruments. The present development opens the way to perform ODMR studies on various new materials such as molecules and luminescent quantum dots where the emission is in the near-infrared range and requires a well-defined excitation wavelength and analysis of the scattered light.

physics.ins-det

A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators

We present a novel method to determine the resonant frequency and quality factor of microwave resonators which is faster, more stable, and conceptually simpler than the yet existing techniques. The microwave resonator is irradiated at a frequency away from its resonance. It then emits an exponentially decaying radiation at its eigen-frequency when the excitation is rapidly switched off. The emission is down-converted with a microwave mixer, digitized and its Fourier transformation (FT) directly yields the resonance curve in a single shot. Being an FT based method, this technique possesses the Fellgett (multiplex) and Connes (accuracy) advantages and it conceptually mimics that of pulsed nuclear magnetic resonance. We also establish a novel benchmark to compare accuracy of the different approaches of microwave resonator measurements. This shows that the present method have similar accuracy to the existing ones.

cond-mat.other

A Fourier transform Raman spectrometer with visible laser excitation

We present the development and performance of a Fourier transformation (FT) based Raman spectrometer working with visible laser (532 nm) excitation. It is generally thought that FT-Raman spectrometers are not viable in the visible range where shot-noise limits the detector performance and therein they are outperformed by grating based, dispersive ones. We show that contrary to this common belief, the recent advances of high-performance interference filters makes the FT-Raman design a valid alternative to dispersive Raman spectrometers for samples which do not luminesce. We critically compare the performance of our spectrometer to two dispersive ones: a home-built single channel and a state-of-the-art CCD based instruments. We demonstrate a similar or even better sensitivity than the CCD based dispersive spectrometer particularly when the laser power density is considered. The instrument possesses all the known advantages of the FT principle of spectral accuracy, high throughput, and economic design. We also discuss the general considerations which helps the community reassess the utility of the different Raman spectrometer designs.

physics.optics