SearcharxivSearch

arXiv subjects

B. Harrop

Publications and source records attributed to B. Harrop.

3 recordsLinked to original sources

Deep Diffused Avalanche Photodiodes for Charged Particles Timing

The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of 180 ps, a time resolution of about 30 ps is needed. The timing detectors will experience a 1-MeV neutron equivalent fluence of about $\Phi_{eq}=10^{14}$ and $10^{15}$ cm$^{-2}$ for the barrel and end-cap regions, respectively. In this contribution, deep diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate timing detectors for HL-LHC applications. To improve the detector's timing performance, the APDs are used to directly detect the traversing particles, without a radiator medium where light is produced. Devices with an active area of $8\times8$ mm$^2$ were characterized in beam tests. The timing performance and signal properties were measured as a function of position on the detector using a beam telescope and a microchannel plate photomultiplier (MCP-PMT). Devices with an active area of $2\times2$ mm$^2$ were used to determine the effects of radiation damage and characterized using a ps pulsed laser. These detectors were irradiated with neutrons up to $\Phi_{eq}=10^{15}$ cm$^{-2}$.

physics.ins-det

Deep Diffused APDs for Charged Particle Timing Applications: Performance after Neutron Irradiation

Recent interest in pile-up mitigation through fast timing at the HL-LHC has focused attention on technologies that now achieve minimum ionising particle (MIP) time resolution of 30 picoseconds or less. The constraints of technical maturity and radiation tolerance narrowed the options in this rapidly developing field for the ATLAS and CMS upgrades to low gain avalanche detectors and silicon photomultipliers. In a variety of applications where occupancies and doses are lower, devices with pixel elements of order 1 cm$^2$, nevertheless achieving 30 ps, would be attractive. In this paper, deep diffused Avalanche Photo Diodes (APDs) are examined as candidate timing detectors for HL-LHC applications. Devices with an active area of $8 \times 8$ mm$^2$ are characterised using a pulsed infrared laser and, in some cases, high energy particle beams.The timing performance as well as the uniformity of response are examined. The effects of radiation damage on current, signal amplitude, noise, and timing of the APDs are evaluated using detectors with an active area of $2 \times 2$ mm$^2$. These detectors were irradiated with neutrons up to a a 1-MeV neutrons fluence $\Phi_{eq} = 10^{15}$ cm$^{-2}$. Their timing performance was characterised using a pulsed infrared laser. While a time resolution of $27 \pm 1$ ps was obtained in a beam test using an $8 \times 8$ mm$^2$ sensor, the present study only demonstrates that gain loss can be compensated by increased detector bias up to fluences of $\Phi_{eq} = 6 \cdot 10^{13}$ cm$^{-2}$. So it possibly falls short of the $\Phi_{eq} = 10^{14}$ cm$^{-2}$ requirement for the CMS barrel over the lifetime of the HL-LHC.

physics.ins-det

Development of a Relic Neutrino Detection Experiment at PTOLEMY: Princeton Tritium Observatory for Light, Early-Universe, Massive-Neutrino Yield

The PTOLEMY experiment (Princeton Tritium Observatory for Light, Early-Universe, Massive-Neutrino Yield) aims to achieve the sensitivity required to detect the relic neutrino background through a combination of a large area surface-deposition tritium target, MAC-E filter methods, cryogenic calorimetry, and RF tracking and time-of-flight systems. A small-scale prototype is in operation at the Princeton Plasma Physics Laboratory with the goal of validating the technologies that would enable the design of a 100 gram PTOLEMY. With precision calorimetry in the prototype setup, the limitations from quantum mechanical and Doppler broadening of the tritium target for different substrates will be measured, including graphene substrates. Beyond relic neutrino physics, sterile neutrinos contributing to the dark matter in the universe are allowed by current constraints on partial contributions to the number of active neutrino species in thermal equilibrium in the early universe. The current PTOLEMY prototype is expected to have unique sensitivity in the search for sterile neutrinos with electron-flavor content for masses of 0.1--1keV, where less stringent, 10eV, energy resolution is required. The search for sterile neutrinos with electron-flavor content with the 100g PTOLEMY is expected to reach the level $|U_{e4}|^2$ of $10^{-4}$--$10^{-6}$, depending on the sterile neutrino mass.

astro-ph.IM