HTS Undulator Design Study and First Results

Undulators are X-ray sources that are widely utilised in advanced synchrotron radiation sources and freeelectron laser facilities. Due to sustainability and energy efficiency, the development focuses on small-scale, high-field, and especially compact undulators with short period lengths ($\leq$ 10 mm) and narrow magnetic gaps ($\leq$ 4 mm). Therefore, hightemperature superconducting (HTS) tapes, which can provide a high critical current density and high critical magnetic fields at higher temperatures, are extensively used and investigated at the Karlsruhe Institute of Technology. A new concept of superconducting undulators (SCUs) was introduced and further developed by laser-scribing a meander pattern into the superconducting layer to achieve a quasi-sinusoidal current path through the HTS tape. Here we present the complete and final design of such a compact SCU, in particular our latest results regarding the design of the liner with its tapering in the warm region, as well as the cryogenic cooling concept.

physics.acc-ph

KIT Superconducting Undulator Development -- Story of a successful industrial collaboration & future prospects

Undulators are X-ray sources widely used in synchrotron storage rings and free-electron laser facilities. With the commercial availability of low-temperature superconductors, a new type of undulator was born, the superconducting undulator (SCU). In this context, the industrial cooperation between the Karlsruhe Institute of Technology and Bilfinger Nuclear and Energy Transition GmbH started more than 15 years ago. Since then, many projects have been successfully completed, leading to the production of the world's leading full-scale commercial SCUs based on conduction cooling. Starting with the SCU15, the first of its kind installed SCU providing light to a beamline, followed by the SCU20 installed and still in operation at the Karlsruhe Research Accelerator. The successful realisation of such SCUs has required the simultaneous development of appropriate measurement facilities such as CASPER I and CASPER II.

physics.acc-ph

Search for keV-scale Sterile Neutrinos with first KATRIN Data

In this work we present a keV-scale sterile-neutrino search with the first tritium data of the KATRIN experiment, acquired in the commissioning run in 2018. KATRIN performs a spectroscopic measurement of the tritium $\beta$-decay spectrum with the main goal of directly determining the effective electron anti-neutrino mass. During this commissioning phase a lower tritium activity facilitated the search for sterile neutrinos with a mass of up to $1.6\, \mathrm{keV}$. We do not find a signal and set an exclusion limit on the sterile-to-active mixing amplitude of down to $\sin^2\theta < 5\cdot10^{-4}$ ($95\,\%$ C.L.), improving current laboratory-based bounds in the sterile-neutrino mass range between 0.1 and $1.0\, \mathrm{keV}$.

nucl-ex

Search for Lorentz-Invariance Violation with the first KATRIN data

Some extensions of the Standard Model of Particle Physics allow for Lorentz invariance and Charge-Parity-Time (CPT)-invariance violations. In the neutrino sector strong constraints have been set by neutrino-oscillation and time-of-flight experiments. However, some Lorentz-invariance-violating parameters are not accessible via these probes. In this work, we focus on the parameters $(a_{\text{of}}^{(3)})_{00}$, $(a_{\text{of}}^{(3)})_{10}$ and $(a_{\text{of}}^{(3)})_{11}$ which would manifest themselves in a non-isotropic beta-decaying source as a sidereal oscillation and an overall shift of the spectral endpoint. Based on the data of the first scientific run of the KATRIN experiment, we set the first limit on $\left|(a_{\text{of}}^{(3)})_{11}\right|$ of $< 3.7\cdot10^{-6}$ GeV at 90\% confidence level. Moreover, we derive new constraints on $(a_{\text{of}}^{(3)})_{00}$ and $(a_{\text{of}}^{(3)})_{10}$.

nucl-ex

KATRIN: Status and Prospects for the Neutrino Mass and Beyond

The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.

nucl-ex

New Constraint on the Local Relic Neutrino Background Overdensity with the First KATRIN Data Runs

We report on the direct cosmic relic neutrino background search from the first two science runs of the KATRIN experiment in 2019. Beta-decay electrons from a high-purity molecular tritium gas source are analyzed by a high-resolution MAC-E filter around the kinematic endpoint at 18.57 keV. The analysis is sensitive to a local relic neutrino overdensity of 9.7e10 (1.1e11) at a 90% (95%) confidence level. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint accounting for relic neutrino captures in the Tritium source reveals no significant overdensity. This work improves the results obtained by the previous kinematic neutrino mass experiments at Los Alamos and Troitsk. We furthermore update the projected final sensitivity of the KATRIN experiment to <1e10 at 90% confidence level, by relying on updated operational conditions.

nucl-ex

Improved eV-scale Sterile-Neutrino Constraints from the Second KATRIN Measurement Campaign

We present the results of the light sterile neutrino search from the second KATRIN measurement campaign in 2019. Approaching nominal activity, $3.76 \times 10^6$ tritium $\beta$-electrons are analyzed in an energy window extending down to $40\,$eV below the tritium endpoint at $E_0 = 18.57\,$keV. We consider the $3\nu+1$ framework with three active and one sterile neutrino flavor. The analysis is sensitive to a fourth mass eigenstate $m_4^2\lesssim1600\,$eV$^2$ and active-to-sterile mixing $|U_{e4}|^2 \gtrsim 6 \times 10^{-3}$. As no sterile-neutrino signal was observed, we provide improved exclusion contours on $m_4^2$ and $|U_{e4}|^2$ at $95\,$% C.L. Our results supersede the limits from the Mainz and Troitsk experiments. Furthermore, we are able to exclude the large $\Delta m_{41}^2$ solutions of the reactor antineutrino and gallium anomalies to a great extent. The latter has recently been reaffirmed by the BEST collaboration and could be explained by a sterile neutrino with large mixing. While the remaining solutions at small $\Delta m_{41}^2$ are mostly excluded by short-baseline reactor experiments, KATRIN is the only ongoing laboratory experiment to be sensitive to relevant solutions at large $\Delta m_{41}^2$ through a robust spectral shape analysis.

hep-ex

First direct neutrino-mass measurement with sub-eV sensitivity

We report the results of the second measurement campaign of the Karlsruhe Tritium Neutrino (KATRIN) experiment. KATRIN probes the effective electron anti-neutrino mass, $m_{\nu}$, via a high-precision measurement of the tritium $\beta$-decay spectrum close to its endpoint at $18.6\,\mathrm{keV}$. In the second physics run presented here, the source activity was increased by a factor of 3.8 and the background was reduced by $25\,\%$ with respect to the first campaign. A sensitivity on $m_{\nu}$ of $0.7\,\mathrm{eV/c^2}$ at $90\,\%$ confidence level (CL) was reached. This is the first sub-eV sensitivity from a direct neutrino-mass experiment. The best fit to the spectral data yields $m_{\nu}^2 = (0.26\pm0.34)\,\mathrm{eV^4/c^4}$, resulting in an upper limit of $m_{\nu}<0.9\,\mathrm{eV/c^2}$ ($90\,\%$ CL). By combining this result with the first neutrino mass campaign, we find an upper limit of $m_{\nu}<0.8\,\mathrm{eV/c^2}$ ($90\,\%$ CL).

hep-ex

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $\beta$-decay endpoint region with a sensitivity on $m_\nu$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $\beta$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $\beta$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $\sigma(m_\nu^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.

physics.ins-det

Analysis methods for the first KATRIN neutrino-mass measurement

We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $\beta$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $\beta$ electrons are guided along magnetic field lines toward a high-resolution, integrating spectrometer for energy analysis. A silicon detector counts $\beta$ electrons above the energy threshold of the spectrometer, so that a scan of the thresholds produces a precise measurement of the high-energy spectral tail. After detailed theoretical studies, simulations, and commissioning measurements, extending from the molecular final-state distribution to inelastic scattering in the source to subtleties of the electromagnetic fields, our independent, blind analyses allow us to set an upper limit of 1.1 eV on the neutrino-mass scale at a 90\% confidence level. This first result, based on a few weeks of running at a reduced source intensity and dominated by statistical uncertainty, improves on prior limits by nearly a factor of two. This result establishes an analysis framework for future KATRIN measurements, and provides important input to both particle theory and cosmology.

hep-ex

Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN

We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass $m_{4}$. The analysis is sensitive to a fourth mass state $m^2_{4} \lesssim$ 1000 eV$^2$ and to active-to-sterile neutrino mixing down to $|U_{e4}|^2 \gtrsim 2\cdot10^{-2}$. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results and improve the Troitsk bound for $m^2_{4} <$ 30 eV$^2$. The reactor and gallium anomalies are constrained for $ 100 < \Delta{m}^2_{41} < 1000$ eV$^2$.

hep-ex

Suppression of Penning discharges between the KATRIN spectrometers

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $\beta$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

physics.ins-det

An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN

We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.

hep-ex

First operation of the KATRIN experiment with tritium

The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.

physics.ins-det

High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment

In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.

physics.ins-det

Gamma-induced background in the KATRIN main spectrometer

The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overline{\nu}_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.

physics.ins-det

Muon-induced background in the KATRIN main spectrometer

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.

physics.ins-det

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.

physics.ins-det