SearcharxivSearch

arXiv subjects

B. Krause

Publications and source records attributed to B. Krause.

9 recordsLinked to original sources

Evidence for parity violation in gravitational fields

Discrete symmetries in gravity have only been tested for low energy, non-relativistic matter, confirming the perfectly symmetric general relativity. A hint for high energy $\cal{CP}$ violation in gravitational fields has recently been found in the HERA Compton polarimeter's two spectra, measured with electron and positron beams. Here we report results of the analysis of the same polarimeter's 314896 spectra, acquired during 2004--2007 and tagged by laser polarization states allowing the separation of charge ($\cal C$) and space parity ($\cal P$) contributions. The measured Compton edge energy asymmetry, induced by the laser helicity flips, is as high as $(4.9\pm0.5)\cdot10^{-5}$ which corresponds to a helicity-dependent difference in the gravitational potentials of $(1.7\pm0.2)\cdot10^{-14}$. In the case of the observed anomalous coupling's energy independence, the spin asymmetric gravity will contribute to the galactic rotational curves. Further analysis and calculations can determine whether the observed magnitude of the gravitational parity violation is sufficient for detaching this famous phenomena from the dark matter theory.

hep-ex

Lattice dynamics of endotaxial silicide nanowires

Self-organized silicide nanowires are considered as main building blocks of future nanoelectronics and have been intensively investigated. In nanostructures, the lattice vibrational waves (phonons) deviate drastically from those in bulk crystals, which gives rise to anomalies in thermodynamic, elastic, electronic, and magnetic properties. Hence, a thorough understanding of the physical properties of these materials requires a comprehensive investigation of the lattice dynamics as a function of the nanowire size. We performed a systematic lattice dynamics study of endotaxial FeSi$_2$ nanowires, forming the metastable, surface-stabilized $α$-phase, which are in-plane embedded into the Si(110) surface. The average widths of the nanowires ranged from 24 to 3 nm, their lengths ranged from several $μ$m to about 100 nm. The Fe-partial phonon density of states, obtained by nuclear inelastic scattering, exhibits a broadening of the spectral features with decreasing nanowire width. The experimental data obtained along and across the nanowires unveiled a pronounced vibrational anisotropy that originates from the specific orientation of the tetragonal $α$-FeSi$_2$ unit cell on the Si(110) surface. The results from first-principles calculations are fully consistent with the experimental data and allow for a comprehensive understanding of the lattice dynamics of endotaxial silicide nanowires.

cond-mat.mtrl-sci

Lattice dynamics and polarization-dependent phonon damping in $α$-phase FeSi$_{2}$ nanoislands

We determined the lattice dynamics of metastable, surface-stabilized $α$-phase FeSi$_2$ nanoislands epitaxially grown on the Si(111) surface with average heights and widths ranging from 1.5 to 20 nm and 18 to 72 nm, respectively. The crystallographic orientation, surface morphology and local crystal structure of the nanoislands were investigated by reflection high-energy electron diffraction, atomic force microscopy and X-ray absorption spectroscopy. The Fe-partial phonon density of states (PDOS), obtained by nuclear inelastic scattering, exhibits a pronounced damping and broadening of the spectral features with decreasing average island height. First-principles calculations of the polarization-projected Si- and Fe-partial phonon dispersions and PDOS enable the disentanglement of the contribution of the $xy$- and $z$-polarized phonons to the experimental PDOS. Modeling of the experimental data with the theoretical results unveils an enhanced damping of the $z$-polarized phonons for islands with average sizes below 10 nm. This phenomenon is attributed to the fact that the low-energy $z$-polarized phonons couple to the low-energy surface/interface vibrational modes. The thermodynamic and elastic properties obtained from the experimental data show a pronounced size-dependent behavior.

cond-mat.mtrl-sci

The HERMES Recoil Detector

For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1 T. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.

physics.ins-det

Direct strain and elastic energy evaluation in rolled-up semiconductor tubes by x-ray micro-diffraction

We depict the use of x-ray diffraction as a tool to directly probe the strain status in rolled-up semiconductor tubes. By employing continuum elasticity theory and a simple model we are able to simulate quantitatively the strain relaxation in perfect crystalline III-V semiconductor bi- and multilayers as well as in rolled-up layers with dislocations. The reduction in the local elastic energy is evaluated for each case. Limitations of the technique and theoretical model are discussed in detail.

cond-mat.mtrl-sci

Late growth stages and post-growth diffusion in organic epitaxy: PTCDA on Ag(111)

The late growth stages and the post-growth diffusion of crystalline organic thin films have been investigated for 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA) on Ag(111), a model system in organic epitaxy. In situ x-ray measurements at the anti-Bragg point during the growth show intensity oscillations followed by a time-independent intensity which is independent of the growth temperature. At T > 350 K, the intensity increases after growth up to a temperature-dependent saturation value due to a post-growth diffusion process. The time-independent intensity and the subsequent intensity recovery have been reproduced by models based on the morphology change as a function of the growth temperature. The morphology found after the post-growth diffusion processes has been studied by specular rod measurements.

cond-mat.soft

Design, Commissioning and Performance of the PIBETA Detector at PSI

We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.

hep-ex

Light response of pure CsI calorimeter crystals painted with wavelength-shifting lacquer

We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted with a special wavelength-shifting solution were examined in a custom-build detection apparatus (RASTA=radioactive source tomography apparatus) that uses a 137Cs radioactive gamma source, cosmic muons and a light emitting diode as complementary probes of the scintillator light response. We have extracted the total light output, axial light collection nonuniformities and timing responses of the individual CsI crystals. These results predict improved performance of the 3 pi sr PIBETA calorimeter due to the painted lateral surfaces of 240 CsI crystals. The wavelength-shifting paint treatment did not affect appreciably the total light output and timing resolution of our crystal sample. The predicted energy resolution for positrons and photons in the energy range of 10-100 MeV was nevertheless improved due to the more favorable axial light collection probability variation. We have compared simulated calorimeter ADC spectra due to 70 MeV positrons and photons with a Monte Carlo calculation of an ideal detector light response.

hep-ex

Cosmic muon tomography of pure cesium iodide calorimeter crystals

Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the pi+ -> pi0 e+ nu decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were examined in a multiwire drift chamber system specially designed for transmission cosmic muon tomography. Critical elements of the apparatus and reconstruction algorithms enabling measurement of spatial detector optical nonuniformities are described. Results are compared with a Monte Carlo simulation of the light response of an ideal detector. The deduced optical nonuniformity contributions to the FWHM energy resolution of the PIBETA CsI calorimeter for the pi+ -> e+ nu 69.8 MeV positrons and the monoenergetic 70.8 MeV photons were 2.7% and 3.7%, respectively. The upper limit of optical nonuniformity correction to the 69.8 MeV positron low-energy tail between 5 MeV and 55 MeV was +0.2%, as opposed to the +0.3% tail contribution for the photon of the equivalent total energy. Imposing the 5 MeV calorimeter veto cut to suppress the electromagnetic losses, GEANT-evaluated positron and photon lineshape tail fractions summed over all above-threshold ADCs were found to be 2.36+-0.05(stat)+-0.20(sys)% and 4.68+-0.07(stat)+-0.20(sys)%, respectively.

hep-ex