SearcharxivSearch

arXiv subjects

B. R. Barquest

Publications and source records attributed to B. R. Barquest.

4 recordsLinked to original sources

Mass Measurements of Neutron-Rich Gallium Isotopes Refine Production of Nuclei of the First r-Process Abundance Peak in Neutron Star Merger Calculations

We report mass measurements of neutron-rich Ga isotopes $^{80-85}$Ga with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The measurements determine the masses of $^{80-83}$Ga in good agreement with previous measurements. The masses of $^{84}$Ga and $^{85}$Ga were measured for the first time. Uncertainties between $25-48$ keV were reached. The new mass values reduce the nuclear uncertainties associated with the production of A $\approx$ 84 isotopes by the \emph{r}-process for astrophysical conditions that might be consistent with a binary neutron star (BNS) merger producing a blue kilonova. Our nucleosynthesis simulations confirm that BNS merger may contribute to the first abundance peak under moderate neutron-rich conditions with electron fractions $Y_e=0.35-0.38$.

nucl-ex

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

A precision mass investigation of the neutron-rich titanium isotopes $^{51-55}$Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the $N=32$ shell closure and the overall uncertainties of the $^{52-55}$Ti mass values were significantly reduced. Our results confirm the existence of a weak shell effect at $N=32$, establishing the abrupt onset of this shell closure. Our data were compared with state-of-the-art \textit{ab-initio} shell model calculations which, despite very successfully describing where the $N=32$ shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements also represent the first scientific results of TITAN using the newly commissioned Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS), substantiated by independent measurements from TITAN's Penning trap mass spectrometer.

nucl-ex

Precision mass measurements of $^{125-127}$Cd isotopes and isomers approaching the $N=82$ closed shell

We present the results of precision mass measurements of neutron-rich cadmium isotopes. These nuclei approach the $N=82$ closed neutron shell and are important to nuclear structure as they lie near doubly-magic $^{132}$Sn on the chart of nuclides. Of particular note is the clear identification of the ground state mass in $^{127}$Cd along with the isomeric state. We show that the ground state identified in a previous mass measurement which dominates the mass value in the Atomic Mass Evaluation is an isomeric state. In addition to $^{127/m}$Cd, we present other cadmium masses measured ($^{125/m}$Cd and $^{126}$Cd) in a recent TITAN experiment at TRIUMF. Finally, we compare our measurements to new \emph{ab initio} shell-model calculations and comment on the state of the field in the $N=82$ region.

nucl-ex

A Novel Transparent Charged Particle Detector for the CPET Upgrade at TITAN

The detection of an electron bunch exiting a strong magnetic field can prove challenging due to the small mass of the electron. If placed too far from a solenoid's entrance, a detector outside the magnetic field will be too small to reliably intersect with the exiting electron beam because the light electrons will follow the diverging magnetic field outside the solenoid. The TITAN group at TRIUMF in Vancouver, Canada, has made use of advances in the practice and precision of photochemical machining (PCM) to create a new kind of charge collecting detector called the "mesh detector." The TITAN mesh detector was used to solve the problem of trapped electron detection in the new Cooler PEnning Trap (CPET) currently under development at TITAN. This thin array of wires etched out of a copper plate is a novel, low profile, charge agnostic detector that can be made effectively transparent or opaque at the user's discretion.

physics.ins-det