SearcharxivSearch

arXiv subjects

B. T. Hackett

Publications and source records attributed to B. T. Hackett.

8 recordsLinked to original sources

Gamma Backgrounds for Experiments at the High Flux Isotope Reactor

This article describes the deployment of a germanium detector at Oak Ridge National Lab's High Flux Isotope Reactor (HFIR) for the purpose of understanding the energy and spatial distribution of the gamma field in the experiment hall where the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) took data and future neutrino experiments could be located. The sources from both the reactor and the neutron beamlines are described in detail, along with their temporal variations due to reactor power and their spatial variations due to the geometry of the beamlines and building materials in the vicinity. Additionally, a shielding study was performed to assess the amount that backgrounds in tens of keV range can be mitigated. This work helps inform backgrounds for future experiments at reactors such as IBD-based neutrino measurements and CEvNS measurements.

hep-ex

Improved Short-Baseline Neutrino Oscillation Search and Energy Spectrum Measurement with the PROSPECT Experiment at HFIR

We present a detailed report on sterile neutrino oscillation and U-235 antineutrino energy spectrum measurement results from the PROSPECT experiment at the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. In 96 calendar days of data taken at an average baseline distance of 7.9 m from the center of the 85 MW HFIR core, the PROSPECT detector has observed more than 50,000 interactions of antineutrinos produced in beta decays of U-235 fission products. New limits on the oscillation of antineutrinos to light sterile neutrinos have been set by comparing the detected energy spectra of ten reactor-detector baselines between 6.7 and 9.2 meters. Measured differences in energy spectra between baselines show no statistically significant indication of antineutrinos to sterile neutrino oscillation and disfavor the Reactor Antineutrino Anomaly best-fit point at the 2.5$σ$ confidence level. The reported U-235 antineutrino energy spectrum measurement shows excellent agreement with energy spectrum models generated via conversion of the measured U-235 beta spectrum, with a $χ^2$/DOF of 31/31. PROSPECT is able to disfavor at 2.4$σ$ confidence level the hypothesis that U-235 antineutrinos are solely responsible for spectrum discrepancies between model and data obtained at commercial reactor cores. A data-model deviation in PROSPECT similar to that observed by commercial core experiments is preferred with respect to no observed deviation, at a 2.2$σ$ confidence level.

hep-ex

Note on arXiv:2005.05301, 'Preparation of the Neutrino-4 experiment on search for sterile neutrino and the obtained results of measurements'

We comment on the claimed observation [arXiv:arXiv:2005.05301] of sterile neutrino oscillations by the Neutrino-4 collaboration. Such a claim, which requires the existence of a new fundamental particle, demands a level of rigor commensurate with its impact. The burden lies with the Neutrino-4 collaboration to provide the information necessary to prove the validity of their claim to the community. In this note, we describe aspects of both the data and analysis method that might lead to an oscillation signature arising from a null experiment and describe additional information needed from the Neutrino-4 collaboration to support the oscillation claim. Additionally, as opposed to the assertion made by the Neutrino-4 collaboration, we also show that the method of 'coherent summation' using the $L/E$ parameter produces similar results to the methods used by the PROSPECT and the STEREO collaborations.

hep-ex

The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.

physics.ins-det

Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT

This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.

nucl-ex

A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector

PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overlineν_e$ interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis, and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.

physics.ins-det

Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment

This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.

physics.ins-det

First search for short-baseline neutrino oscillations at HFIR with PROSPECT

This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of $^{235}$U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton $^6$Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 meter water equivalent overburden. Data collected during 33 live-days of reactor operation at a nominal power of 85 MW yields a detection of 25461 $\pm$ 283 (stat.) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5$σ$ statistical significance within two hours of on-surface reactor-on data-taking. A reactor-model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the Reactor Antineutrino Anomaly at 2.2$σ$ confidence level.

hep-ex