SearcharxivSearch

arXiv subjects

B. Vallage

Publications and source records attributed to B. Vallage.

12 recordsLinked to original sources

Characterization and performance of an upgraded front-end-board for NectarCAM

This paper presents an analysis of the updated version of the Front-End Board (FEB) for the NectarCAM camera, developed for the Cherenkov Telescope Array Observatory (CTAO). The FEB is a critical component responsible for reading and converting signals from the camera's photo-multiplier tubes into digital data and generating module-level trigger signals. This study provides an overview of the design and performance of the new FEB version, including the use of an improved NECTAr3 chip with advanced features. The NECTAr3 chip contains a switched capacitor array for sampling signals at 1 GHz and a 12-bit analog-to-digital converter (ADC) for digitization upon receiving a trigger signal. The integration of the new NECTAr3 chip results in a significant reduction of NectarCAM's deadtime by an order of magnitude compared to the previous version. The paper also presents the results of laboratory testing, including measurements of timing performance, linearity, dynamic range, and deadtime, to characterize the new FEB's performance.

astro-ph.IM

Timing performances of NectarCAM, a Medium Sized Telescope Camera for the Cherenkov Telescope Array

NectarCAM is a Cherenkov camera that will be installed on Medium-Sized Telescopes of the northern array of the Cherenkov Telescope Array Observatory (CTAO). It is composed of 265 modules, each of which includes 7 photo-multiplier tubes, a Front-End Board and a camera trigger system for data collection. The first NectarCAM unit is currently being integrated at CEA Paris-Saclay in France. Once installed at the CTAO's northern site, the NectarCAM's timing abilities will be crucial for reducing noise in images, improving image cleaning, and distinguishing between gamma-ray photons and cosmic-ray background. Additionally, it will enable coincidence identification with neighboring telescopes for stereoscopic observations. The timing system of NectarCAM has been tested in a dark room with various light sources. The results of the tests, including timing precision and accuracy of the trigger arrival relative to a laser source, and the timing of individual and multiple pixel signals, will be presented.

astro-ph.IM

Performances of an upgraded front-end-board for the NectarCAM camera

The Front-End Board (FEB) is a key component of the NectarCAM camera, which has been developed for the Medium-Sized-Telescopes (MST) of the Cherenkov Telescope Array Observatory (CTAO). The FEB is responsible for reading and converting the signals from the camera's photo-multiplier tubes (PMTs) into digital data, as well as generating module level trigger signals. This contribution provides an overview of the design and performances of a new version of the FEB that utilizes an improved version of the NECTAr chip. The NECTAr chip includes a switched capacitor array for sampling signals at 1 GHz, and a 12-bit analog-to-digital converter (ADC) for digitizing each sample when the trigger signal is received. The integration of this advanced NECTAr chip significantly reduces the deadtime of NectarCAM by an order of magnitude as compared to the previous version. This contribution also presents the results of laboratory testing of the new FEB, including measurements of timing performance, linearity, dynamic range, and deadtime.

astro-ph.IM

The NectarCAM Timing System

NectarCAM is a Cherenkov camera which is going to equip the Medium-Sized Telescopes (MST) of the northern site of the Cherenkov Telescope Array Observatory (CTAO). NectarCAM is equipped with 265 modules, each consisting of 7 photo-multiplier tubes (PMTs), a Front-End Board and a local camera trigger system used for data acquisition. This paper addresses the timing performance of NectarCAM which are crucial to reduce the noise in shower images and improve image cleaning as well as to discriminate between gamma-ray photons and cosmic-ray background and finally to allow coincidence identification with neighbouring telescopes for stereoscopic operations. Verification tests of the system have been performed in a dark room using various light sources to illuminate the first NectarCAM unit. The resulting timing precision and accuracy of the trigger arrival relative to a laser source, of individual and multiple pixel signals have been studied and are shown to comply to CTAO requirements.

astro-ph.IM

Production of antihydrogen atoms by 6 keV antiprotons through a positronium cloud

We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The antiproton beam was delivered by the AD/ELENA facility. The positronium target was produced from a positron beam itself obtained from an electron linear accelerator. We observe an excess over background indicating antihydrogen production with a significance of 3-4 standard deviations.

hep-ex

Positron accumulation in the GBAR experiment

We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), which has been cooled to a low temperature, and observing the subsequent H annihilation following free fall. To produce one H+ ion, about 10^10 positrons, efficiently converted into positronium (Ps), together with about 10^7 antiprotons (p), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) x 10^9 positrons in 1100 seconds.

physics.plasm-ph

Positron production using a 9 MeV electron linac for the GBAR experiment

For the GBAR (Gravitational Behaviour of Antihydrogen at Rest) experiment at CERN's Antiproton Decelerator (AD) facility we have constructed a source of slow positrons, which uses a low-energy electron linear accelerator (linac). The driver linac produces electrons of 9 MeV kinetic energy that create positrons from bremsstrahlung-induced pair production. Staying below 10 MeV ensures no persistent radioactive activation in the target zone and that the radiation level outside the biological shield is safe for public access. An annealed tungsten-mesh assembly placed directly behind the target acts as a positron moderator. The system produces $5\times10^7$ slow positrons per second, a performance demonstrating that a low-energy electron linac is a superior choice over positron-emitting radioactive sources for high positron flux.

physics.ins-det

Science Case for a Wide Field-of-View Very-High-Energy Gamma-Ray Observatory in the Southern Hemisphere

We outline the science motivation for SGSO, the Southern Gamma-Ray Survey Observatory. SGSO will be a next-generation wide field-of-view gamma-ray survey instrument, sensitive to gamma-rays in the energy range from 100 GeV to hundreds of TeV. Its science topics include unveiling galactic and extragalactic particle accelerators, monitoring the transient sky at very high energies, probing particle physics beyond the Standard Model, and the characterization of the cosmic ray flux. SGSO will consist of an air shower detector array, located in South America. Due to its location and large field of view, SGSO will be complementary to other current and planned gamma-ray observatories such as HAWC, LHAASO, and CTA.

astro-ph.HE

Multiwavelength study of the region around the ANTARES neutrino excess

The ANTARES collaboration reported the results of a search for point-like neutrino sources using data taken in the period 2007-2010. An unbinned maximum likelihood based all-sky search yielded a cluster of 9 (5) events within a cone of 3 (1) degrees around (R.A., Dec) = (-46.5deg, -65.0deg). The trial factor corrected p-value of 2.6% (2.2 sigma) is not significant enough to claim the observation of an astrophysical point source. However, it currently constitutes the most significant localized neutrino excess observed by ANTARES. Here we present a multi-wavelength analysis including optical to X-ray archival data and a dedicated analysis of gamma-ray data from Fermi-LAT. In order to cover the TeV domain, dedicated observations with the H.E.S.S. telescope array were carried out. We present these data and discuss implications of the results in terms of signatures for a cosmic-ray acceleration site.

astro-ph.HE

Measurement of the branching ratio of the decay $Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$

From the 2002 data taking with a neutral kaon beam extracted from the CERN-SPS, the NA48/1 experiment observed 97 $Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$ candidates with a background contamination of $30.8 \pm 4.2$ events. From this sample, the BR($Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$) is measured to be $(2.17 \pm 0.32_{\mathrm{stat}}\pm 0.17_{\mathrm{syst}})\times10^{-6}$.

hep-ex

Search for neutrinos from transient sources with the ANTARES telescope and optical follow-up observations

The ANTARES telescope has the opportunity to detect transient neutrino sources, such as gamma-ray bursts, core-collapse supernovae, flares of active nuclei... To enhance the sensitivity to these sources, we have developed a new detection method based on the optical follow-up of "golden" neutrino events such as neutrino doublets coincident in time and space or single neutrinos of very high energy. The ANTARES Collaboration has therefore implemented a very fast on-line reconstruction with a good angular resolution. These characteristics allow to trigger an optical telescope network; since February 2009. ANTARES is sending alert trigger one or two times per month to the two 25 cm robotic telescope of TAROT. This follow-up of such special events would not only give access to the nature of the sources but also improves the sensitivity for transient neutrino sources.

astro-ph.HE

Neutrino detection of transient sources with optical follow-up observations

The ANTARES telescope has the opportunity to detect transient neutrino sources, such as gamma-ray bursts (GRBs), core-collapse supernovae (SNe), flares of active galactic nuclei (AGNs)... To enhance the sensitivity to these sources, we are developing a new detection method based on the observation of neutrino bursts followed by an optical detection. The ANTARES Collaboration is implementing a fast on-line event reconstruction with a good angular resolution. These characteristics allow to trigger an optical telescope network in order to identify the nature of the neutrinos (and high energy cosmic-rays) sources. This follow-up can be done with a network of small automatic telescopes and required a small observation time. An optical follow-up of special events, such as neutrino doublets in coincidence in time and space or single neutrino having a very high energy, would not only give access to the nature of the sources but also improve the sensitivity for neutrino detection from SNe or GRBs.

astro-ph