SearcharxivSearch

arXiv subjects

B. Vogelaar

Publications and source records attributed to B. Vogelaar.

5 recordsLinked to original sources

Search for two-neutrino double electron capture in $^{36}$Ar with the DarkSide-50 detector

Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shells and two neutrinos are emitted. We report on the first search for two-neutrino double electron capture in the $\textit{KK}$- and $\textit{KL}$-shells of $^{36}$Ar using the low-radioactivity liquid argon target from underground sources in the DarkSide-50 experiment. No statistically significant excess was observed with approximately 12 ton-day exposure of underground argon (UAr) and, taking into account the $^{36}$Ar isotopic abundance in UAr (0.007%), we set a limit on the half-life of the two-electron capture process in $^{36}$Ar of $T_{1/2} > 9.2 \times 10^{19}$ yr at 90% C.L. The sensitivity of the DarkSide-20k experiment, which will become operational in the next few years, was also evaluated and is expected to increase by a factor $\sim$100 with 10 years of expected operation and assuming the same $^{36}$Ar abundance as in the DarkSide-50 underground argon target.

nucl-ex

White Paper on Light Sterile Neutrino Searches and Related Phenomenology

This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.

hep-ex

Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment

In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trapping mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trapping in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.

physics.ins-det

Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection

The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $τ_n$ that does not require corrections larger than the quoted uncertainties.

nucl-ex

A new method for measuring the neutron lifetime using an in situ neutron detector

The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.

nucl-ex