SearcharxivSearch

arXiv subjects

B. Weigand

Publications and source records attributed to B. Weigand.

5 recordsLinked to original sources

Effect of Acoustics on Droplet Grouping Behaviour in a Single Stream of Droplets

Droplet and particle grouping can be influenced by applying an acoustic field and have practical applications such as particle scavenging and aerosol filters of engine exhaust and air purifiers. The present work experimentally investigates the influence of a standing acoustic wave on a single stream of droplets. The experimental setup consists of an acoustic transducer and a reflector plate through which the droplet stream passes in the presence or absence of an external pressure field generated by a standing acoustic wave. A droplet stream is generated with the help of a nozzle connected to a pressurized working fluid supply and piezoelectric transducer to control the spacing between droplets. The effect of the acoustic pressure field on the droplet stream generated by the nozzle operated at different piezoelectric excitation frequencies and fluid pressures is investigated. Droplet stream characteristics at every nozzle excitation frequency are observed with a high-speed camera when the acoustic field is switched OFF and ON. The competing effect of nozzle excitation frequency and acoustic field is observed. At lower nozzle frequencies, the nozzle generates an unstable stream of droplets having different sizes and spacings between them. When the acoustic field is applied at these lower frequencies, the stream of droplets becomes organized, and in some cases, it becomes equispaced and of the same size. However, an opposite behavior is observed at higher frequencies. In these cases, as the acoustic field is applied, an equispaced mono-disperse droplet stream becomes unstable due to the coalescence of droplets within the stream.

physics.flu-dyn

Design of a test rig for the investigation of falling film flows with counter-current gas flows

Geothermal phase change probes operate on the principle of falling film evaporation, enabling the efficient use of geothermal heat for space heating applications. Despite successful applications in research, their commercial use is limited. One of the primary reasons for this is the absence of validated models capable of accurately representing the falling film flow coupled with counter-current gas flow within these probes. For this reason, a test rig has been developed to facilitate the validation of future models. This test rig allows for the replication of flow phenomena appearing within geothermal probes under controlled conditions. The test rig was successfully tested within the first measurement campaign presented in this paper. Within the framework of this measurement campaign water was used as liquid due to its similar Kapitza number compared to \(CO_{2}\), typically used within geothermal probes, and humid air as gas. For the gas phase, velocity profiles were measured and for the liquid phase high temporal resolution film thickness measurements were conducted. Both measurement systems show qualitative comparable results to literature. Additionally, the sampled film thickness data were averaged to enable a time-independent interpretation. The investigation of the average film thickness in flow direction, without gas flow, revealed an increase in film thickness along flow direction for \(Re_{film}=500\). In contrast, for \(Re_{film}\geq 980\), an opposing trend was observed. Furthermore, the influence of gas flow on the average film thickness was investigated. The measurement results and high-speed camera images indicate that the test rig is capable of reaching flooding conditions.

physics.flu-dyn

Azimuthal variation of apparent contact angles on structured surfaces featuring micrometric ramps, pyramids and staggered cubes at two different inherent wettabilities

As new manufacturing methods enable manufacturing of microstructured surfaces with varying structure geometries, questions remain on some effects on the wetting behavior and the resulting apparent contact angles. In this study, we report the manufacturing process using 3D Direct Laser Writing (3D-DLW) and hot embossing for Poly-methylmethacrylate (PMMA) surfaces with micrometric pyramids, cubes on a staggered grid and two types of ramped structures. We measure the azimuthal variation of the apparent contact angle of sessile droplets on the surfaces. Using plasma polymerization or no treatment of the surfaces, two different inherent wettabilities are studied. We find that while all structure types cause an azimuthal variation of the apparent contact angle, pinning at the ramp tops increases the contact angle more strongly on one side. On pyramid structures, pinning lines can occur on the structure axes and diagonals similarly. For cubes on a hexagonal grid, the strongest contact angle increases are observed along the primary structure axes, where pinning is preferred while smaller peaks are seen on the secondary axes at 60{\deg} and 120{\deg} to the primary axis.

cond-mat.soft

Drop impact on wetted walls: An analytical solution for modelling the crown spreading based on stagnation-point flow

An analytical solution is proposed to predict the crown propagation, generated by a single droplet impact on wetted walls. This approach enables a smooth transition from the inertia-driven to the viscous-controlled regime of crown propagation. The modelling strategy is based on the stagnation-point flow, because it resembles closely the hydrodynamic flow in the lamella and offers two main advantages. First, it allows a simple estimation of the wall-film thinning rate, caused by the impulse transfer from the impacting droplet to the wall film. Second, thanks to the self-similarity of the solution, it enables a straightforward estimation of momentum losses during film spreading along the wall. By incorporating this estimation into existing inviscid models, an excellent agreement with experiments is found during the entire crown elevation phase. In general, the analysis shows that momentum losses due to viscous effects cannot be neglected during a significant portion of crown propagation, particularly for thin wall films. The proposed methodology paves the way for predicting the inception of crown bottom breakup (CBB). In this case, the crown lamella disintegrates directly at its base due to the spontaneous creation of holes that create a web-like structure in the lamella prior to its break-up. Our theoretical analysis shows that this premature break-up of the crown lamella is associated to local instability effects, caused by the unbalance between inertial forces and surface tension.

physics.flu-dyn

Miscibility and wettability: how interfacial tension influences droplet impact onto thin wall films

The influence of miscibility and liquid wettability during droplet impact onto thin wall films is investigated experimentally. Despite similar liquid properties and impact conditions, differences in the splashing limit, the crown extension and the duration of the ascending phase are observed. These differences are related to the interfacial tension of the droplet/wall-film liquid pairs, which is linked to their miscibility and wettability. More precisely, by calculating the crown surface energy, we show that the energy stored in the interface between droplet and wall-film (if any) is not negligible and leads to smaller crown extensions and the need of more kinetic energy to initiate splashing. Similarly, by calculating a modified capillary time taking into account all surface and interfacial tensions, we show that the interfacial tension acts as a non-negligible recoiling force, which reduces the duration of the ascending phase. The dynamics of this ascending phase is well captured for different wall-film thicknesses if accounting for the variations of the liquid masses in movement. Overall, droplet/wall-film interactions can be seen as inertio-capillary systems where the interfacial tension between droplet and wall film plays a significant role in the storage of energy and in the crown kinetics during the impact process. Besides, this analysis highlights that viscous losses have already a significant effect during the crown extension phase, by dissipating almost half of the initial energies for droplet impact onto thin wall films, and most likely by influencing the capillary time scale through damping.

physics.flu-dyn