SiPM non-linearity studies in beam tests with scintillating crystals

High-granularity homogeneous electromagnetic calorimeters based on scintillating crystals and silicon photomultipliers (SiPMs) are a promising option for future $e^{+}e^{-}$ Higgs factories, where both excellent energy resolution and a very large dynamic range are required. In this work, the non-linear response of high-pixel-density SiPMs with pixel pitches of 6--10~$μ$m coupled to BGO and BSO crystals is studied under realistic beam conditions. A dual-end readout scheme with an attenuated reference SiPM was employed to precisely calibrate the deposited energy and the corresponding number of photoelectrons over a wide dynamic range. Beam tests were carried out at the CERN SPS H2 beamline using high-energy electrons, with a tungsten pre-shower and variable incident angles to enhance energy deposition. The measurements directly quantify the non-linear response of SiPMs to scintillation light over an extended dynamic range. For BGO-coupled Hamamatsu SiPMs, deviations from linearity of about 20\% are observed at $5\times10^{5}$ photoelectrons, while larger deviations are measured for the tested NDL devices and for configurations with faster BSO scintillation.

physics.ins-det

Conceptual Design of a Novel Highly Granular Crystal Electromagnetic Calorimeter for Future Higgs Factories

Next-generation high-energy electron-positron colliders, operating as Higgs factories, require an unprecedented jet energy resolution for precision measurements of Higgs and Z/W bosons. To address this challenge, a conceptual design is presented for a novel high-granularity crystal electromagnetic calorimeter that combines the superior intrinsic energy resolution of a homogeneous calorimeter with the fine segmentation required for particle-flow reconstruction. The crystal electromagnetic calorimeter design is based on orthogonally arranged long scintillating crystal bars read out by silicon photomultipliers (SiPMs) at both ends. Key design specifications were established through comprehensive simulation studies. Critical technical considerations, including crystal choices, photosensors, electronics, mechanical support, and radiation damage, are discussed. A dedicated digitisation framework was developed to realistically model effects from the crystal, SiPMs, and readout electronics. The performance of a single calorimeter module was evaluated using simulated electron showers. Simulation results for a single module demonstrate an excellent electromagnetic energy resolution of $1.12\%/\sqrt{E(\mathrm{GeV})}\oplus0.22\%$ and an energy linearity within $\pm0.5\%$ for electrons from 3 GeV to 100 GeV. The performance significantly exceeds the design requirement of $\leq 3\%/\sqrt{E(\mathrm{GeV})}\oplus1\%$. The results establish the feasibility of the proposed high-granularity crystal calorimeter concept and point to a promising pathway toward the precision calorimetry required for future high-energy electron-positron collider experiments.

physics.ins-det

Lab and Beam Tests of a SiPM-readout ASIC with a Large Dynamic Range

A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large dynamic range for the readout of the silicon photomultiplier (SiPM), has been tested in the laboratory and at a test beam facility. The fundamental performance metrics have been characterised, including response linearity, inter-calibration factor and noise performance. To quantitatively assess the dynamic range of the chip and evaluate its feasibility for SiPM readout in high-granularity crystal ECAL, a beamtest was conducted using scintillating crystals exposed to electron beams. Beamtest results showed that the chip exhibits a promising performance in terms of a good signal-to-noise ratio and a relatively large dynamic range.

physics.ins-det

Measurements on Time Resolution of BGO, PWO and BSO Crystals

A high-granularity crystal calorimeter (HGCCAL) has been proposed for the future Circular Electron Positron Collider (CEPC). This study investigates the time resolution of various crystal - Silicon Photomultiplier (SiPM) detection units for HGCCAL, focusing on Bismuth Germanate (BGO), Lead Tungstate (PWO), and Bismuth Silicon Oxide (BSO) crystals. Beam tests were conducted using 10 GeV pions at CERN and 5 GeV electrons at DESY, enabling systematic comparisons of timing performance under both minimum ionizing particle (MIP) signals and electromagnetic (EM) showers. Three timing methods - constant fraction timing (CFT) with sampled points, linear fitting, and exponential fitting - were evaluated, with an exponential fit combined with a 10% constant fraction providing the best time resolution. Measurements of crystal units with different dimensions revealed that both scintillation light yield and signal rise time influence timing performance. Among similarly sized crystals, PWO exhibited the best time resolution due to its fast signal rise time, while BGO and BSO demonstrated comparable timing performance. For long BGO bars (40 cm and 60 cm), the time resolution remained uniform along their length, achieving approximately 0.75 ns and 0.95 ns for MIP signals. Under intense EM showers, both bars reached a timing resolution of approximately 200 ps at high amplitudes. And the presence of upstream pre-shower layers can introduce additional timing fluctuations at similar amplitudes.

physics.ins-det

Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL

A proposal for the CEPC ECAL is a highly-granular scintillating crystal design that uses SiPMs to measure physics signals from photons. Radiation damage to the silicon will impair the performance of the calorimeter due to dark noise, which will affect the reconstruction capabilities of the calorimeter system. This paper presents a simulation study assessing the effect of radiation damage of SiPM dark noise on the response from calorimeter to electrons due to changing fluence and temperature. It was observed that dark noise significantly degrades the linearity of response, with up to 45% error in reconstructed energy for a 1 GeV shower at a fluence of $1 \times 10^{10}\mathrm{cm}^{-2}$. The stochastic and noise resolution terms was observed to remain stable, increasing only by 0.2% and 1% respectively in the range $1 \times 10^{7}-1 \times 10^{10}\mathrm{cm}^{-2}$ fluence. Under the assumption of no irradiation, the influence of dark noise with temperature in the normal operating range of the calorimeter system was estimated to be negligible.

physics.ins-det

Dynamic Range of SiPMs with High Pixel Densities

This study investigates the characteristics of Silicon Photomultipliers (SiPMs) with different pixel densities, focusing on their response across a wide dynamic range. Using an experimental setup that combines laser source and photomultiplier tubes (PMTs) for accurate light intensity calibration, we evaluated SiPMs with pixel counts up to 244,719 and pixel sizes down to 6 micrometers. To complement the experimental findings, a "Toy Monte Carlo" was developed to replicate the SiPMs' reponses under different lighting conditions, incorporating essential parameters such as pixel density and photon detection efficiency. The simulations aligned well with the experimental results for laser light, demonstrating similar nonlinearity trends. For BGO scintillation light, the simulations, which included multi-firing effect of pixels, showed significantly higher photon counts compared to the laser simulations. Furthermore, the simulated response derived in this research offer a method to correct for SiPM saturation effect, enabling accurate measurements in high-energy events even with SiPMs having a limited number of pixels.

physics.ins-det

Muon beamtest results of high-density glass scintillator tiles

To achieve the physics goal of precisely measure the Higgs, Z, W bosons and the top quark, future electron-positron colliders require that their detector system has excellent jet energy resolution. One feasible technical option is the high granular calorimetery based on the particle flow algorithm (PFA). A new high-granularity hadronic calorimeter with glass scintillator tiles (GSHCAL) has been proposed, which focus on the significant improvement of hadronic energy resolution with a notable increase of the energy sampling fraction by using high-density glass scintillator tiles. The minimum ionizing particle (MIP) response of a glass scintillator tile is crucial to the hadronic calorimeter, so a dedicated beamtest setup was developed for testing the first batch of large-size glass scintillators. The maximum MIP response of the first batch of glass scintillator tiles can reach up to 107 p.e./MIP, which essentially meets the design requirements of the CEPC GSHCAL. An optical simulation model of a single glass scintillator tile has been established, and the simulation results are consistent with the beamtest results.

physics.ins-det

Study of residual artificial neural network for particle identification in the CEPC high-granularity calorimeter prototype

Particle Identification (PID) plays a central role in associating the energy depositions in calorimeter cells with the type of primary particle in a particle flow oriented detector system. In this paper, we propose novel PID methods based on the Residual Network (ResNet) architecture which enable the training of very deep networks, bypass the need to reconstruct feature variables, and ensure the generalization ability among various geometries of detectors, to classify electromagnetic showers and hadronic showers. Using Geant4 simulation samples with energy ranging from 5 GeV to 120 GeV, the efficacy of Residual Connections is validated and the performance of our model is compared with Boosted Decision Trees (BDT) and other pioneering Artificial Neural Network (ANN) approaches. In shower classification, we observe an improvement in background rejection over a wide range of high signal efficiency ($> 95\%$). These findings highlight the prospects of ANN with Residual Blocks for imaging detectors in the PID task of particle physics experiments.

hep-ex

Performance studies of a SiPM-readout system with a pico-second timing chip

A pico-second timing (PIST) front-end electronic chip has been developed using $55~\mathrm{nm}$ CMOS technology for future electron-positron collider experiments (namely Higgs factories). Extensive tests have been performed to evaluate the timing performance of a dedicated SiPM-readout system equipped with a PIST chip. The results show that the system timing resolution can achieve $45~\mathrm{ps}$ for SiPM signals at the minimum-ionizing particles (MIP) level ($200~\mathrm{p.e.}$) and better than $ 10~\mathrm{ps}$ for signals larger than $1200~\mathrm{p.e.}$, while the PIST intrinsic timing resolution is $4.76 \pm 0.60~\mathrm{ps}$. The PIST dynamic range has been further extended using the time-over-threshold (ToT) technique, which can cover the SiPM response spanning from $\mathrm{\sim 900~p.e.}$ to $~\mathrm{\sim 40000~p.e.}$.

physics.ins-det

Charaterization of the first prototype IHEP-NDL LGAD sensor

The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event pile-up of high-luminosity large hadron collider (HL-LHC), a new concept of 4-dimension detector including timing and positon has been proposed. One of the candidates for the 4-dimension detector is a new kind of silicon detector called Low Gain Avalanche Diode (LGAD). In China, Institute of High Energy Physics (IHEP) Chinese Academic Science cooperated with Novel Device Laboratory (NDL) at Beijing Normal University have fabricated a series of LGAD sensors. The characterization of the first prototype of IHEP-NDL sensors is presented including leakage current and sensor capacitance measurement. A test system for the time resolution of jitter term using pico-second laser and fast sampling rate oscilloscope is also setup, and the time resolution of 10 ps can be achieved with these sensors.

physics.ins-det