Virtual Dosimetrists: A Radiotherapy Training "Flight Simulator"

Effective education in radiotherapy plan quality review requires a robust, regularly updated set of examples and the flexibility to demonstrate multiple possible planning approaches and their consequences. However, the current clinic-based paradigm does not support these needs. To address this, we have developed 'Virtual Dosimetrist' models that can both generate training examples of suboptimal treatment plans and then allow trainees to improve the plan quality through simple natural language prompts, as if communicating with a dosimetrist. The dose generation and modification process is accurate, rapid, and requires only modest resources. This work is the first to combine dose distribution prediction with natural language processing; providing a robust pipeline for both generating suboptimal training plans and allowing trainees to practice their critical plan review and improvement skills that addresses the challenges of the current clinic-based paradigm.

physics.med-ph

OAR-Weighted Dice Score: A spatially aware, radiosensitivity aware metric for target structure contour quality assessment

The Dice Similarity Coefficient (DSC) is the current de facto standard to determine agreement between a reference segmentation and one generated by manual / auto-contouring approaches. This metric is useful for non-spatially important images; however, radiation therapy requires consideration of nearby Organs-at-Risk (OARs) and their radiosensitivity which are currently unaccounted for with the traditional DSC. In this work, we introduce the OAR-DSC which accounts for nearby OARs and their radiosensitivity when computing the DSC. We illustrate the importance of this through cases where two proposed contours have similar DSC, but lower OAR-DSC when one contour expands closer to the surrounding OARs. This work is important because the OAR-DSC may be used by deep learning auto-contouring algorithms in a radiation therapy specific loss function, thereby progressing on the current disregard for the importance of these differences on the final radiation dose plan generation, delivery, and risks of patient toxicity.

physics.med-ph

Evolving Horizons in Radiotherapy Auto-Contouring: Distilling Insights, Embracing Data-Centric Frameworks, and Moving Beyond Geometric Quantification

Deep learning has significantly advanced the potential for automated contouring in radiotherapy planning. In this manuscript, guided by contemporary literature, we underscore three key insights: (1) High-quality training data is essential for auto-contouring algorithms; (2) Auto-contouring models demonstrate commendable performance even with limited medical image data; (3) The quantitative performance of auto-contouring is reaching a plateau. Given these insights, we emphasize the need for the radiotherapy research community to embrace data-centric approaches to further foster clinical adoption of auto-contouring technologies.

physics.med-ph

Deep Learning-Based Dose Prediction for Automated, Individualized Quality Assurance of Head and Neck Radiation Therapy Plans

Purpose: This study aimed to use deep learning-based dose prediction to assess head and neck (HN) plan quality and identify suboptimal plans. Methods: A total of 245 VMAT HN plans were created using RapidPlan knowledge-based planning (KBP). A subset of 112 high-quality plans was selected under the supervision of an HN radiation oncologist. We trained a 3D Dense Dilated U-Net architecture to predict 3-dimensional dose distributions using 3-fold cross-validation on 90 plans. Model inputs included CT images, target prescriptions, and contours for targets and organs at risk (OARs). The model's performance was assessed on the remaining 22 test plans. We then tested the application of the dose prediction model for automated review of plan quality. Dose distributions were predicted on 14 clinical plans. The predicted versus clinical OAR dose metrics were compared to flag OARs with suboptimal normal tissue sparing using a 2 Gy dose difference or 3% dose-volume threshold. OAR flags were compared to manual flags by 3 HN radiation oncologists. Results: The predicted dose distributions were of comparable quality to the KBP plans. The differences between the predicted and KBP-planned D1%, D95%, and D99% across the targets were within -2.53%(SD=1.34%), -0.42%(SD=1.27%), and -0.12%(SD=1.97%), respectively, and the OAR mean and maximum doses were within -0.33Gy(SD=1.40Gy) and -0.96Gy(SD=2.08Gy). For the plan quality assessment study, radiation oncologists flagged 47 OARs for possible plan improvement. There was high interphysician variability; 83% of physician-flagged OARs were flagged by only one of 3 physicians. The comparative dose prediction model flagged 63 OARs, including 30 of 47 physician-flagged OARs. Conclusion: Deep learning can predict high-quality dose distributions, which can be used as comparative dose distributions for automated, individualized assessment of HN plan quality.