Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.

physics.med-ph

Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and developing tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner. Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial field-of-view, and detector configuration, and eight J-PET scanners with various field-of-view, plastic scintillator cross-sections, and layers were performed. Biograph Vision was also simulated. Two types of simulations were conducted with a central source and a water-filled phantom. Results: BGO crystal-based scanners showed the best sensitivity (350 cps/kBq at the center). Sparse geometry or LYSO crystals reduced sensitivity. J-PET design showed similar sensitivity to sparse LYSO detectors, with full body coverage and additional gain for brain imaging. Conclusion: The J-PET tomography system using plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners, overcoming high construction costs while maintaining sensitivity

physics.med-ph

Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.

nucl-ex

Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with cross section of 6 mm times 30 mm and length of 140 cm or 200 cm) arranged in two layers in regular 24-sided polygon circumscribing a circle with the diameter of 78.6 cm. For the TB-J-PET with an axial field-of-view (AFOV) of 200 cm, a spatial resolutions of 3.7 mm (transversal) and 4.9 mm (axial) are achieved. The NECR peak of 630 kcps is expected at 30 kBq/cc activity concentration and the sensitivity at the center amounts to 38 cps/kBq. The SF is estimated to 36.2 %. The values of SF and spatial resolution are comparable to those obtained for the state-of-the-art clinical PET scanners and the first total-body tomographs: uExplorer and PennPET. With respect to the standard PET systems with AFOV in the range from 16 cm to 26 cm, the TB-J-PET is characterized by an increase in NECR approximately by factor of 4 and by the increase of the whole-body sensitivity by factor of 12.6 to 38. The TOF resolution for the TB-J-PET is expected to be at the level of CRT=240 ps (FWHM). For the TB-J-PET with an axial field-of-view (AFOV) of 140 cm, an image quality of the reconstructed images of a NEMA IEC phantom was presented with a contrast recovery coefficient (CRC) and a background variability parameters. The increase of the whole-body sensitivity and NECR estimated for the TB-J-PET with respect to current commercial PET systems makes the TB-J-PET a promising cost-effective solution for the broad clinical applications of total-body PET scanners.

physics.ins-det

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were performed. The spatial resolution, the sensitivity, the scatter fraction and the noise equivalent count rate were estimated according to the NEMA norm as a function of the length of the tomograph, number of the detection layers, diameter of the tomographic chamber and for various types of the applied readout. For the single-layer geometry with the diameter of 85 cm, strip length of 100 cm, cross-section of 4 mm x 20 mm and silicon photomultipliers with the additional layer of wavelength shifter as the readout, the spatial resolution (FWHM) in the centre of the scanner is equal to 3 mm (radial, tangential) and 6 mm (axial). For the analogous double-layer geometry with the same readout, diameter and scintillator length, with the strip cross-section of 7 mm x 20 mm, the NECR peak of 300 kcps was reached at 40 kBq/cc activity concentration, the scatter fraction is estimated to about 35% and the sensitivity at the centre amounts to 14.9 cps/kBq. Sensitivity profiles were also determined.

physics.ins-det

Unified treatment of the total angular momentum of single photons via generalized quantum observables

In this paper we provide a consistent framework to address the notorious decomposition of the single-photon total angular momentum (TAM) into a spin (SAM) and an orbital (OAM) component. In particular, we find that the canonical SAM and OAM, generators of internal and spatial rotations respectively in the space of physical states, are mutually compatible but unsharp quantum observables, therefore POVM (Positive Operator-Valued Measures) describe their joint measurements. On the other hand, a non-canonical SAM and OAM can be constructed that is mutually incompatible but represent sharp quantum observables, thus PVM (Projector-Valued Measurements), reflecting their consistency with the transversality condition characterizing singlephoton wavefunctions. We discuss the implementations on joint measurements for both decompositions and provide an explicit calculation of all these quantities for circularly polarized Gaussian single-photon states.

quant-ph

Detection and typicality of bound entangled states

We derive an explicit analytic estimate for the entanglement of a large class of bipartite quantum states which extends into bound entanglement regions. This is done by using an efficiently computable concurrence lower bound, which is further employed to numerically construct a volume of $3 \times 3$ bound entangled states.

quant-ph

A special simplex in the state space for entangled qudits

Focus is on two parties with Hilbert spaces of dimension d, i.e. "qudits". In the state space of these two possibly entangled qudits an analogue to the well known tetrahedron with the four qubit Bell states at the vertices is presented. The simplex analogue to this magic tetrahedron includes mixed states. Each of these states appears to each of the two parties as the maximally mixed state. Some studies on these states are performed, and special elements of this set are identified. A large number of them is included in the chosen simplex which fits exactly into conditions needed for teleportation and other applications. Its rich symmetry - related to that of a classical phase space - helps to study entanglement, to construct witnesses and perform partial transpositions. This simplex has been explored in details for d=3. In this paper the mathematical background and extensions to arbitrary dimensions are analysed.

quant-ph