SearcharxivSearch

arXiv subjects

Benito Gimeno

Publications and source records attributed to Benito Gimeno.

15 recordsLinked to original sources

Resonant heterodyne conversion applied to a low-frequency haloscope for dark matter axion searches in the 1-35 MHz range

We study resonant heterodyne up-conversion in the RADES-BabyIAXO haloscope as a method to search for low-mass dark matter axions using microwave cavities. Starting from axion electrodynamics, we derive the axion-induced source term and the power extracted through a readout mode, explicitly accounting for the finite axion linewidth. This leads to effective quality factors that determine the pump-axion mixing, detection bandwidth, and detected signal power. We extend the BI-RME 3D full-wave formulation to heterodyne axion detection in a realistic two-port cavity, including pump leakage into the readout channel. Applying the formalism to the largest RADES-BabyIAXO cavity identifies the $\mathrm{quasi\textrm{-}TE}_{011}-\mathrm{quasi\textrm{-}TM}_{010}$ mode pair as a favorable configuration, enabling sensitivity to axion frequencies between 0.9 and 34.6 MHz. Analytical and full-wave predictions show excellent agreement at resonance, while the full-wave model provides a more accurate description off resonance and allows a precise characterization of the pump leakage. We also derive the optimal port couplings that maximize the scanning rate. Sensitivity projections for cryogenic copper and superconducting niobium cavities indicate that, under thermal-noise-limited conditions and assuming sufficient pump-leakage rejection, the experiment could probe axion-photon couplings down to $10^{-15}\,\mathrm{GeV}^{-1}$ at 90% confidence level, representing a significant improvement over previous heterodyne-based searches.

hep-ex

Global detector network to search for high-frequency gravitational waves (GravNet): conceptual design

We propose GravNet (Global detector network to search for high-frequency gravitational waves), a novel experimental scheme enabling the search for gravitational waves in the MHz to GHz frequency range. Such high-frequency gravitational waves could arise from a variety of phenomena connected to some of the most pressing and fundamental questions in modern cosmology. The GravNet concept is based on synchronous measurements of signals from multiple experimental measurement devices operating at geographically separated locations. While gravitational-wave-induced signatures may be present in the signal of a single detector, distinguishing them from instrumental or environmental noise is highly challenging. By analyzing correlations between signals from several distant detectors, the detection significance is substantially enhanced, while simultaneously enabling studies of the nature and origin of the gravitational-wave signal. In this work, we discuss the GravNet concept specifically in the context of cavities operated in strong magnetic fields, as these currently represent the most technically mature and experimentally advanced realization of the scheme. As part of this proposal, a first demonstration experiment using a non-superconducting cavity has been performed, providing the basis for the data-analysis strategies discussed in this work. Finally, we outline the prospects and future development of GravNet as a global network for high-frequency gravitational-wave searches.

astro-ph.IM

The COSMIC WISPers White Paper: The physics case for Weakly Interacting Slim Particles

Axions and other very weakly interacting slim particles (WISPs), with masses below 1 GeV, arise naturally in many extensions of the Standard Model of particle physics. In particular, they could offer a new framework to explain the nature of dark matter and may help address a range of puzzling observations in astrophysics and particle physics. This review provides an overview of ongoing WISP searches and outlines the prospects for the next decade, spanning their theoretical motivation, indirect signatures in astrophysical observations, and dedicated laboratory experiments. It is based on the work carried on by the EU-funded COST Action ``Cosmic WISPers in the Dark Universe: Theory, astrophysics, and experiments'' (CA21106, https://www.cost.eu/actions/CA21106). This network plays a key role in coordinating and supporting WISP searches across Europe, while also contributing to the development of a roadmap aimed at securing European leadership in this research area. It is emphasized that Europe is currently pursuing a rich, diverse, and cost-effective experimental program, with the potential to deliver one or more transformative discoveries.

hep-ph

Enhancement of dark-photon haloscope sensitivity with degenerate modes: toward axion-level form factor and polarization determination

The dark photon has been postulated as a potential constituent of dark matter, exhibiting notable similarities to the axion. The primary distinction between the two particles lies in the nature of their respective fields: the dark photon field is a vector field with a polarization direction that remains undetermined. This work explores the prospect of utilizing three degenerate modes for scanning the three dimensions of space in order to mitigate the low form factor expected in the detection of the dark photon due to their unknown polarization. The employment of an haloscope with three orthogonal and degenerate modes in conjunction with the coherent sum of signals is demonstrated in this work in order to enhance the dark photon form factor up to the axion form factor, and to determine the direction of the dark photon polarization vector. We show in this manuscript that the maximum form factor is achieved in cavities of cubic, spherical, and cylindrical geometries, considering the introduction of tuning elements. To achieve this adequately, some conditions reviewed in this article must be fulfilled in the resonant cavity, leading to uncertainties in the final measurement. Finally, this technique can allow the simultaneous search for dark matter axions and dark photons, and to the knowledge of the authors, the method shown in this work is the most effective one for detecting dark photon with microwave resonant cavities.

hep-ph

Performance of High-Intensity Electron Linacs as Drivers for Compact Neutron Sources

The demand for neutron production facilities is increasing, as the applications of neutron science are manifold. These applications drive the need for efficient and compact neutron sources. In this context, this paper explores the potential performance of normal-conducting compact electron linacs from 20 MeV to 500 MeV as drivers for neutron sources. Results from a G4BEAMLINE simulation study find optimum dimensions of a tungsten target and characterize the emitted neutron spectrum. Two electron linac are then evaluated as drivers of such target: HPCI, an X-band linac; and CTF3 drive beam linac, an S-band alternative. The simulation study shows neutron strength values up to $1.5\cdot 10^{15}$ n/s can be attained, as well as low energy consumed per neutron produced values up to $5.65 \cdot 10^{-10}$ J/n, suggesting these electron-based neutron sources may be a compact and energy-efficient solution for many research, industry and medical applications.

physics.acc-ph

Multiple-cavities interferometric analysis for dark matter axions directional-sensitive search based on signal cross-correlation processing

Current axion detection limits neglect the relevance of the relative velocity between the axion field and the detectors. However, this aspect can lead to a daily modulation of the detected axion signal. In this work, we calculate the cross-correlation of various signals potentially originated in multiple-cavity setups, and we analyze how the signal-to-noise ratio and directional sensitivity depend on the signal cross-correlation among multiple cavities. The signal-to-noise ratio after cross-correlation exhibits a greater rate of increase over time compared to the power-summation technique, making it clear that this method could be potentially employed in a real setup for the reduction of the exposure time. For the study of the daily modulation, three interferometric experiments have been proposed in this manuscript: (i) three rectangular cavities in different Earth locations; (ii) three rectangular cavities located in the same Earth spot but oriented towards different perpendicular directions; (iii) six rectangular cavities in the same Earth location but oriented towards different directions. In each set-up, we have simulated three different cavity lengths. Similar results have been found for the cases (i) and (ii): when the highest length upon the three proposed is considered, a phase difference between the recorded voltages of more than $2^{\circ}$ has been obtained with our numerical calculations. We observe a daily modulation in the imaginary part of the signals cross-correlation for experiment (iii), that could be potentially used for the characterization of the axion velocity distribution. To the knowledge of the authors, this is the first time that the cross-correlation technique has been applied to the directional sensitivity analysis of an array of haloscopes.

hep-ex

Dark Matter Axion Detection with Neural Networks at Ultra-Low Signal-to-Noise Ratio

We present the first analysis of Dark Matter axion detection applying neural networks for the improvement of sensitivity. The main sources of thermal noise from a typical read-out chain are simulated, constituted by resonant and amplifier noises. With this purpose, an advanced modal method employed in electromagnetic modal analysis for the design of complex microwave circuits is applied. A feedforward neural network is used for a boolean decision (there is axion or only noise), and robust results are obtained: the neural network can improve by a factor of $5\cdot 10^{3}$ the integration time needed to reach a given signal to noise ratio. This could either significantly reduce measurement times or achieve better sensitivities with the same exposure durations.

hep-ex

High-frequency gravitational waves detection with the BabyIAXO haloscopes

We present the first analysis using RADES-BabyIAXO cavities as detectors of high-frequency gravitational waves (HFGWs). In particular, we discuss two configurations for distinct frequency ranges of HFGWs: Cavity 1, mostly sensitive at a frequency range of 252.8 - 333.2 MHz, and Cavity 2, at 2.504 - 3.402 GHz, which is a scaled down version of Cavity 1. We find that Cavity 1 will reach sensitivity to strains of the HFGWs of order $h_1\sim 10^{-21}$, while Cavity 2 will reach $h_2\sim 10^{-20}$. These represent the best estimations of the RADES-BabyIAXO cavities as HFGWs detectors, showing how this set-up can produce groundbreaking results in axion physics and HFGWs simultaneously.

hep-ex

Study of a cubic cavity resonator for gravitational waves detection in the microwave frequency range

The direct detection of gravitational waves (GWs) of frequencies above MHz has recently received considerable attention. In this work we present a precise study of the reach of a cubic cavity resonator to GWs in the microwave range, using for the first time tools allowing to perform realistic simulations. Concretely, the BI-RME 3D method, which allows us to obtain not only the detected power but also the detected voltage (magnitude and phase), is used here. After analyzing three cubic cavities for different frequencies and working simultaneously with three different degenerate modes at each cavity, we conclude that the sensitivity of the experiment is strongly dependent on the polarization and incidence angle of the GW. The presented experiment can reach sensitivities up to $ 1 \cdot 10^{-19}$ at 100\, MHz, $ 2 \cdot 10^{-20}$ at 1\, GHz, and $ 6 \cdot 10^{-19}$ at 10\, GHz for optimal angles and polarizations, and where in all cases we assumed an integration time of $Δt = 1$ ms. These results provide a strong case for further developing the use of cavities to detect GWs. Moreover, the possibility of analyzing the detected voltage (magnitude and phase) opens a new interferometric detection scheme based on the combination of the detected signals from multiple cavities.

hep-ph

Dielectric Assist Accelerating Structures for Compact Linear Accelerators of Low Energy Particles in Hadrontherapy Treatments

Dielectric Assist Accelerating (DAA) structures based on ultralow-loss ceramic are being studied as an alternative to conventional disk-loaded copper cavities. This accelerating structure consists of dielectric disks with irises arranged periodically in metallic structures working under the TM$_{02}$-$π$ mode. In this paper, the numerical design of an S-band DAA structure for low beta particles, such as protons or carbon ions used for Hadrontherapy treatments, is shown. Four dielectric materials with different permittivity and loss tangent are studied as well as different particle velocities. Through optimization, a design that concentrates most of the RF power in the vacuum space near the beam axis is obtained, leading to a significant reduction of power loss on the metallic walls. This allows to fabricate cavities with an extremely high quality factor, over 100 000, and shunt impedance over 300 M$Ω$/m at room temperature. During the numerical study, the design optimization has been improved by adjusting some of the cell parameters in order to both increase the shunt impedance and reduce the peak electric field in certain locations of the cavity, which can lead to instabilities in its normal functioning.

physics.acc-ph

Non-resonant ultra-fast multipactor regime in dielectric-assist accelerating structures

The objective of this work is the evaluation of the risk of suffering a multipactor discharge in an S-band dielectric-assist accelerating (DAA) structure for a compact low-energy linear particle accelerator dedicated to hadrontherapy treatments. A DAA structure consists of ultra-low loss dielectric ciylinders and disks with irises which are periodically arranged in a metallic enclosure, with the advantage of having an extremely high quality factor and very high shunt impedance at room temperature, and it is therefore proposed as a potential alternative to conventional disk-loaded copper structures. However, it has been observed that these structures suffer from multipactor discharges. In fact, multipactor is one of the main problems of these devices, as it limits the maximum accelerating gradient. Because of this, the analysis of multipactor risk in the early design steps of DAA cavities is crucial to ensure the correct performance of the device after fabrication. In this paper, we present a comprehensive and detailed study of multipactor in our DAA design through numerical simulations performed with an in-house developed code based on the Monte-Carlo method. The phenomenology of the multipactor (resonant electron trajectories, electron flight time between impacts, etc.) is described in detail for different values of the accelerating gradient. It has been found that in these structures an ultra-fast non-resonant multipactor appears, which is different from the types of multipactor theoretically studied in the scientific literature. In addition, the effect of several low electron emission coatings on the multipactor threshold is investigated. Furthermore, a novel design based on the modification of the DAA cell geometry for multipactor mitigation is introduced, which shows a significant increase in the accelerating gradient handling capabilities of our prototype.

physics.acc-ph

The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors

We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented.

hep-ex

Wide-band full-wave electromagnetic modal analysis of the coupling between dark-matter axions and photons in microwave resonators

The electromagnetic coupling axion-photon in a microwave cavity is revisited with the Boundary Integral - Resonant Mode Expansion (BI-RME) 3D technique. Such full-wave modal technique has been applied for the rigorous analysis of the excitation of a microwave cavity with an axion field. In this scenario, the electromagnetic field generated by the axion-photon coupling can be assumed to be driven by equivalent electrical charge and current densities. These densities have been inserted in the general BI-RME 3D equations, which express the RF electromagnetic field existing within a cavity as an integral involving the Dyadic Green functions of the cavity (under Coulomb gauge) as well as such densities. This method is able to take into account any arbitrary spatial and temporal variation of both magnitude and phase of the axion field. Next, we have obtained a simple network driven by the axion current source, which represents the coupling between the axion field and the resonant modes of the cavity. With this approach, it is possible to calculate the extracted and dissipated RF power as a function of frequency along a broad band and without Cauchy-Lorentz approximations, obtaining the spectrum of the electromagnetic field generated in the cavity, and dealing with modes relatively close to the axion resonant mode. Moreover, with this technique we have a complete knowledge of the signal extracted from the cavity, not only in magnitude but also in phase. This can be an interesting issue for future analysis where the axion phase is an important parameter.

hep-ex

Axion Searches with Microwave Filters: the RADES project

We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10-100 $μ$eV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connected by rectangular irises, in an arrangement commonly used in radio-frequency filters. The size of the unit cavity determines the main resonant frequency, while the possibility to connect a {large} number of cavities allows to reach large detection volumes. We develop the theoretical framework of the detection concept, and present design prescriptions to optimize detection capabilities. We describe the design and realization of a first small-scale prototype of this concept, called Relic Axion Detector Exploratory Setup (RADES). It consists of a copper-coated stainless steel five-cavities microwave filter with the detecting mode operating at around 8.4 GHz. This structure has been electromagnetically characterized at 2 K and 298 K, and it is now placed in ultra-high vacuum in one of the twin-bores of the 9 T CAST dipole magnet at CERN. We describe the data acquisition system developed for relic axion detection, and present preliminary results of the electromagnetic properties of the microwave filter, which show the potential of filters to reach QCD axion window sensitivity at X-band frequencies.

hep-ex

Analysis of Metal-Dielectric Waveguides with Circular Sectors

The study of metallic corrugated surfaces has recently received strong attention due to their ability to mimic the behaviour of surface plasmons. In this work, this plasmon-like behaviour is employed to design an open cylindrical waveguide. The structure consists on a longitudinally corrugated metallic cylinder with corrugations filled with a dielectric material. The dispersion relation of this waveguide is analyzed in the Òcontinuous limitÓ, defined as the limit in which the number of corrugations is infinite, but keeping their periodicity constant. It is found that, in this limit, the waveguide supports only TE guided modes and their dispersion relation becomes highly degenerated. Finally, it is shown that the waveguide behaves as an anisotropic cylindrical rod with extreme electromagnetic parameters, what makes it possible to apply these structures not only as waveguides but also as building blocks for metamaterials.

physics.optics