SearcharxivSearch

arXiv subjects

Benjamin Kraus

Publications and source records attributed to Benjamin Kraus.

2 recordsLinked to original sources

Ultra-stable transportable ultraviolet clock laser using cancellation between photo-thermal and photo-birefringence noise

Optical clocks require an ultra-stable laser to probe and precisely measure the frequency of the narrow-linewidth clock transition. We introduce a portable ultraviolet (UV) laser system for use in an aluminum quantum logic clock, demonstrating a fractional frequency instability of approximately $\mathrm{mod}\,\sigma_\mathrm{y} = 2 \times 10^{-16}$. The system is based on an ultra-stable cavity with crystalline AlGaAs/GaAs mirror coatings, alongside with a frequency quadrupling system employing two single-pass second harmonic generation (SHG) stages. Its acceleration sensitivity, measured in all three axes, does not exceed $4(2) \times 10^{-12}$/(ms$^{-2}$) and is among the lowest recorded for transportable systems to date. Additionally, partial cancellation between photo-thermal noise and photo-birefringence noise is used to effectively mitigate noise induced by intra-cavity optical power fluctuation at lower Fourier frequencies.

physics.optics

Phase-stabilized UV light at 267 nm through twofold second harmonic generation

Providing phase stable laser light is important to extend the interrogation time of optical clocks towards many seconds and thus achieve small statistical uncertainties. We report a laser system providing more than 50 uW phase-stabilized UV light at 267.4 nm for an aluminium ion optical clock. The light is generated by frequency-quadrupling a fibre laser at 1069.6 nm in two cascaded non-linear crystals, both in single-pass configuration. In the first stage, a 10 mm long PPLN waveguide crystal converts 1 W fundamental light to more than 0.2 W at 534.8 nm. In the following 50 mm long DKDP crystal, more than 50 uW of light at 267.4 nm are generated. An upper limit for the passive short-term phase stability has been measured by a beat-node measurement with an existing phase-stabilized quadrupling system employing the same source laser. The resulting fractional frequency instability of less than 5 x 10^-17 after 1 s supports lifetime-limited probing of the 27Al^+ clock transition, given a sufficiently stable laser source. A further improved stability of the fourth harmonic light is expected through interferometric path length stabilisation of the pump light by back-reflecting it through the entire setup and correcting for frequency deviations. The in-loop error signal indicates an electronically limited instability of 1 x 10^-18 at 1 s.

physics.optics