SearcharxivSearch

arXiv subjects

Benoit Geslot

Publications and source records attributed to Benoit Geslot.

2 recordsLinked to original sources

Measurement of the $^{35}Cl(n, p)^{35}S$ cross-section at the CERN n\_TOF facility from subthermal energy to 120 keV

Background: The $^{35}Cl(n, p)^{35}S$ reaction is of special interest in three different applications. First, in Boron Neutron Capture Therapy due to the presence of $^{35}Cl$ in brain and skin tissue. Second, it is involved in the creation of $^{36}S$, whose astrophysical origin remains unresolved. Third, in the designing of fast nuclear reactors of new generation based on molten salts. Purpose: To measure the $^{35}Cl(n, p)^{35}S$ cross-section from thermal energy to 120 keV, determine the resonance parameters in this range and Maxwellian Averaged Cross-Section (MACS). Method: We made use of the Time-of-Flight technique with microMEGAS detectors at Experimental Area 2 (EAR-2) of n\_TOF facility at CERN. The $^{10}B(n, \alpha)^{7}Li$ and $^{235}U(n, f)$ reactions were used as references. Rutherford Back-scattering Spectrometry technique was performed at Centro Nacional de Aceleradores (CNA) in Sevilla, in order to accurately determine the masses of the irradiated samples. Results: We obtain a thermal cross-section of $0.470 \pm 0.009$ barns. The $1/v$ energy dependence of the cross-section is observed up to the first resonance at 0.398 keV, the resonances up to 120 keV are analyzed and MACS calculated for $k_{B} T$ from 1 to 100 keV. Conclusions: The $^{35}Cl(n, p)^{35}S$ cross-section has been obtained over a wide energy range for the first time, with high accuracy across the aforementioned range. The thermal cross-section and first two resonances are in agreement with latest evaluation in ENDF/B-VIII.1, while lower resonance strength was found for high energy resonances. These data are used to calculate the MACS for different $k_{B} T$.

nucl-ex

New neutron detector based on Micromegas technology for ADS projects

A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV protons with the spallation target inside the TRIGA core, a full description of the new detector configuration is given. The advantage of this detector compared to conventional neutron flux detectors and the results obtained with the first prototype at the CELINA 14 MeV neutron source facility at CEA-Cadarache are presented. The future developments of operational Piccolo-Micromegas for fast neutron reactors are also described.

physics.ins-det