SearcharxivSearch

arXiv subjects

Berkin Bilgic

Publications and source records attributed to Berkin Bilgic.

At least 19 recordsLinked to original sources

Vendor-Agnostic Joint Relaxometry and Myelin Water Fraction Mapping with B1 and Motion Correction

Obtaining consistent quantitative maps of myelin content and relaxation times across different sites and vendors is essential for advancing our understanding of brain development. Herein, we present a harmonized, vendor-agnostic magnetic resonance acquisition method designed for joint T1, T2, and myelin water fraction mapping, along with a method for rapid B1+ and B1- field estimation. We used our dictionary-based fitting and multi-compartment modeling for joint mapping of T1, T2 and myelin water fraction. Self-navigation-based retrospective motion correction was integrated with subspace reconstruction to track and correct rigid head motion during scanning, operating without the need for external hardware. Simulations, phantom and in vivo experiments confirmed the sensitivity and accuracy of the method, particularly for short T2 values corresponding to myelin, and demonstrated consistent performance across multiple scanner types. Coupled with the harmonized calibration scan, the proposed package offers a practical tool for multi-site, multi-vendor neuroimaging studies in both adult and pediatric populations.

physics.med-ph

MWF-MIMOSA for efficient simultaneous relaxometry and myelin water fraction mapping

Quantitative magnetic resonance imaging (qMRI) provides improved sensitivity and specificity to tissue composition and pathological alterations compared with conventional contrast-weighted imaging. Among various qMRI biomarkers, myelin water imaging is of particular interest because myelin plays a central role in brain function and its alteration is closely associated with many neurological diseases. However, conventional myelin water fraction (MWF) mapping techniques are often limited by long scan times, low spatial resolution, reduced signal-to-noise ratio (SNR), and high specific absorption rate (SAR). Here, we propose MWF-MIMOSA for efficient simultaneous T1, T2, T2* mapping, magnetic susceptibility source separation, and MWF estimation. To achieve this, multi-contrast and multi-slice zero-shot self-supervised learning (MZS-SSL) was used to jointly reconstruct whole-brain complex-valued images. To improve computational efficiency of the parameter estimation step, a multilayer perceptron (MLP) was trained within the GACELLE GPU-accelerated parameter estimation framework to circumvent the computationally intensive Bloch simulation process, resulting in a >100-fold computational speed-up in MWF estimation. Numerical simulations were performed to evaluate the accuracy and precision of MWF-MIMOSA, and in-vivo results further demonstrated its robustness. Comparison with existing myelin water imaging methods showed that MWF-MIMOSA is highly correlated with established approaches, while providing complementary quantitative parameter maps at higher spatial resolution and with shorter scan times. Notably, simultaneous multi-parametric mapping was achieved in 5 min at 1 mm isotropic resolution, and in 10 min at 0.7 mm isotropic resolution. These results demonstrate the potential of MWF-MIMOSA for fast, high-resolution simultaneous relaxometry and myelin water imaging.

physics.med-ph

Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner

Biophysical diffusion MRI models like Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities, neurite fraction, and exchange time. However, NEXI's multi-shell, multi-diffusion-time requirements cause prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, cutting scan time from 27 to 14 minutes. Validated in vivo in seven healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cram'er-Rao Lower Bound (CRLB) theoretical optimum, and two heuristics ("Mid-Range" and "Corner"). It robustly reproduced parameter estimates and maintained test-retest reproducibility. Remarkably, the XAI selection converged to the CRLB optimum. This validates XAI's optimality while highlighting its main advantage: achieving gold-standard optimization without complex analytical Jacobians, making it easily adaptable to numerical models or complex noise where CRLB is intractable. Furthermore, XAI showed superior in vivo robustness over heuristics: "Mid-Range" sampling yielded biased exchange time estimates from insufficient temporal diversity, while "Corner" sampling gave unstable intra-neurite diffusivity estimates (5-fold higher CV) due to noise sensitivity. Ultimately, this robust 14-minute protocol accelerates exchange-sensitive microstructural mapping, establishing a model-agnostic optimization framework adaptable to future ultra-high gradient systems and existing clinical scanners.

physics.med-ph

FINDER: Zero-Shot Field-Integrated Network for Distortion-free EPI Reconstruction in Diffusion MRI

Echo-planar imaging (EPI) remains the cornerstone of diffusion MRI, but it is prone to severe geometric distortions due to its rapid sampling scheme that renders the sequence highly sensitive to $B_{0}$ field inhomogeneities. While deep learning has helped improve MRI reconstruction, integrating robust geometric distortion correction into a self-supervised framework remains an unmet need. To address this, we present FINDER (Field-Integrated Network for Distortion-free EPI Reconstruction), a novel zero-shot, scan-specific framework that reformulates reconstruction as a joint optimization of the underlying image and the $B_{0}$ field map. Specifically, we employ a physics-guided unrolled network that integrates dual-domain denoisers and virtual coil extensions to enforce robust data consistency. This is coupled with an Implicit Neural Representation (INR) conditioned on spatial coordinates and latent image features to model the off-resonance field as a continuous, differentiable function. Employing an alternating minimization strategy, FINDER synergistically updates the reconstruction network and the field map, effectively disentangling susceptibility-induced geometric distortions from anatomical structures. Experimental results demonstrate that FINDER achieves superior geometric fidelity and image quality compared to state-of-the-art baselines, offering a robust solution for high-quality diffusion imaging.

eess.IV

NLCG-Net: A Model-Based Zero-Shot Learning Framework for Undersampled Quantitative MRI Reconstruction

Typical quantitative MRI (qMRI) methods estimate parameter maps in a two-step pipeline that first reconstructs images from undersampled k-space data and then performs model fitting, which is prone to biases and error propagation. We propose NLCG-Net, a model-based nonlinear conjugate gradient (NLCG) framework for joint T2/T1 estimation that incorporates a U-Net regularizer trained in a scan-specific, zero-shot fashion. The method directly estimates qMRI maps from undersampled k-space using mono-exponential signal modeling with scan-specific neural network regularization, enabling high-fidelity T1 and T2 mapping. Experimental results on T2 and T1 mapping demonstrate that NLCG-Net improves estimation quality over subspace reconstruction at high acceleration factors.

eess.IV

Deep learning water-unsuppressed MRSI at ultra-high field for simultaneous quantitative metabolic, susceptibility and myelin water imaging

Purpose: Magnetic Resonance Spectroscopic Imaging (MRSI) maps endogenous brain metabolism while suppressing the overwhelming water signal. Water-unsuppressed MRSI (wu-MRSI) allows simultaneous imaging of water and metabolites, but large water sidebands cause challenges for metabolic fitting. We developed an end-to-end deep-learning pipeline to overcome these challenges at ultra-high field. Methods:Fast high-resolution wu-MRSI was acquired at 7T with non-cartesian ECCENTRIC sampling and ultra-short echo time. A water and lipid removal network (WALINET+) was developed to remove lipids, water signal, and sidebands. MRSI reconstruction was performed by DeepER and a physics-informed network for metabolite fitting. Water signal was used for absolute metabolite quantification, quantitative susceptibility mapping (QSM), and myelin water fraction imaging (MWF). Results: WALINET+ provided the lowest NRMSE (< 2%) in simulations and in vivo the smallest bias (< 20%) and limits-of-agreement (+-63%) between wu-MRSI and ws-MRSI scans. Several metabolites such as creatine and glutamate showed higher SNR in wu-MRSI. QSM and MWF obtained from wu-MRSI and GRE showed good agreement with 0 ppm/5.5% bias and +-0.05 ppm/ +- 12.75% limits-of-agreement. Conclusion: High-quality metabolic, QSM, and MWF mapping of the human brain can be obtained simultaneously by ECCENTRIC wu-MRSI at 7T with 2 mm isotropic resolution in 12 min. WALINET+ robustly removes water sidebands while preserving metabolite signal, eliminating the need for water suppression and separate water acquisitions.

eess.IV

GACELLE: GPU-accelerated tools for model parameter estimation and image reconstruction

Quantitative MRI (qMRI) offers tissue-specific biomarkers that can be tracked over time or compared across populations; however, its adoption in clinical research is hindered by significant computational demands of parameter estimation. Images acquired at high spatial resolution or requiring fitting multiple parameters often require lengthy processing time, constraining their use in routine pipelines and slowing methodological innovation and clinical translation. We present GACELLE, an open source, GPU-accelerated framework for high-throughput qMRI analysis. GACELLE provides a stochastic gradient descent optimiser and a stochastic sampler in MATLAB, enabling fast parameter mapping, improved estimation robustness via spatial regularisation, and uncertainty quantification. GACELLE prioritises accessibility: users only need to provide a forward signal model, while GACELLE's backend manages computational parallelisation, automatic parameter updates, and memory-batching. The stochastic solver performs fully vectorised Markov chain Monte Carlo with identical likelihood on CPU and GPU, ensuring reproducibility across hardware. Benchmarking demonstrates up to 451-fold acceleration for the stochastic gradient descent solver and 14,380-fold acceleration for stochastic sampling compared to CPU-based estimation, without compromising accuracy. We demonstrated GACELLE's versatility on three representative qMRI models and on an image reconstruction task. Across these applications, GACELLE improves parameter precision, enhances test-retest reproducibility, and reduces noise in quantitative maps. By combining speed, usability and flexibility, GACELLE provides a generalisable optimisation framework for medical image analysis. It lowers the computational barrier for qMRI, paving the way for reproducible biomarker development, large-scale imaging studies, and clinical translation.

eess.IV

Omni-QALAS: Optimized Multiparametric Imaging for Simultaneous T1, T2 and Myelin Water Mapping

Purpose: To improve the accuracy of multiparametric estimation, including myelin water fraction (MWF) quantification, and reduce scan time in 3D-QALAS by optimizing sequence parameters, using a self-supervised multilayer perceptron network. Methods: We jointly optimize flip angles, T2 preparation durations, and sequence gaps for T1 recovery using a self-supervised MLP trained to minimize a Cramer-Rao bound-based loss function, with explicit constraints on total scan time. The optimization targets white matter, gray matter, and myelin water tissues, and its performance was validated through simulation, phantom, and in vivo experiments. Results: Building on our previously proposed MWF-QALAS method for simultaneous MWF, T1, and T2 mapping, the optimized sequence reduces the number of readouts from six to five and achieves a scan time nearly one minute shorter, while also yielding higher T1 and T2 accuracy and improved MWF maps. This sequence enables simultaneous multiparametric quantification, including MWF, at 1 mm isotropic resolution within 3 minutes and 30 seconds. Conclusion: This study demonstrated that optimizing sequence parameters using a self-supervised MLP network improved T1, T2 and MWF estimation accuracy, while reducing scan time.

q-bio.QM

A Tutorial on MRI Reconstruction: From Modern Methods to Clinical Implications

MRI is an indispensable clinical tool, offering a rich variety of tissue contrasts to support broad diagnostic and research applications. Clinical exams routinely acquire multiple structural sequences that provide complementary information for differential diagnosis, while research protocols often incorporate advanced functional, diffusion, spectroscopic, and relaxometry sequences to capture multidimensional insights into tissue structure and composition. However, these capabilities come at the cost of prolonged scan times, which reduce patient throughput, increase susceptibility to motion artifacts, and may require trade-offs in image quality or diagnostic scope. Over the last two decades, advances in image reconstruction algorithms--alongside improvements in hardware and pulse sequence design--have made it possible to accelerate acquisitions while preserving diagnostic quality. Central to this progress is the ability to incorporate prior information to regularize the solutions to the reconstruction problem. In this tutorial, we overview the basics of MRI reconstruction and highlight state-of-the-art approaches, beginning with classical methods that rely on explicit hand-crafted priors, and then turning to deep learning methods that leverage a combination of learned and crafted priors to further push the performance envelope. We also explore the translational aspects and eventual clinical implications of these methods. We conclude by discussing future directions to address remaining challenges in MRI reconstruction. The tutorial is accompanied by a Python toolbox (https://github.com/tutorial-MRI-recon/tutorial) to demonstrate select methods discussed in the article.

eess.IV

MIMOSA: Multi-parametric Imaging using Multiple-echoes with Optimized Simultaneous Acquisition for highly-efficient quantitative MRI

Purpose: To develop a new sequence, MIMOSA, for highly-efficient T1, T2, T2*, proton density (PD), and source separation quantitative susceptibility mapping (QSM). Methods: MIMOSA was developed based on 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) by combining 3D turbo Fast Low Angle Shot (FLASH) and multi-echo gradient echo acquisition modules with a spiral-like Cartesian trajectory to facilitate highly-efficient acquisition. Simulations were performed to optimize the sequence. Multi-contrast/-slice zero-shot self-supervised learning algorithm was employed for reconstruction. The accuracy of quantitative mapping was assessed by comparing MIMOSA with 3D-QALAS and reference techniques in both ISMRM/NIST phantom and in-vivo experiments. MIMOSA's acceleration capability was assessed at R = 3.3, 6.5, and 11.8 in in-vivo experiments, with repeatability assessed through scan-rescan studies. Beyond the 3T experiments, mesoscale quantitative mapping was performed at 750 um isotropic resolution at 7T. Results: Simulations demonstrated that MIMOSA achieved improved parameter estimation accuracy compared to 3D-QALAS. Phantom experiments indicated that MIMOSA exhibited better agreement with the reference techniques than 3D-QALAS. In-vivo experiments demonstrated that an acceleration factor of up to R = 11.8-fold can be achieved while preserving parameter estimation accuracy, with intra-class correlation coefficients of 0.998 (T1), 0.973 (T2), 0.947 (T2*), 0.992 (QSM), 0.987 (paramagnetic susceptibility), and 0.977 (diamagnetic susceptibility) in scan-rescan studies. Whole-brain T1, T2, T2*, PD, source separation QSM were obtained with 1 mm isotropic resolution in 3 min at 3T and 750 um isotropic resolution in 13 min at 7T. Conclusion: MIMOSA demonstrated potential for highly-efficient multi-parametric mapping.

physics.med-ph

PRIME: Phase Reversed Interleaved Multi-Echo acquisition enables highly accelerated distortion-free diffusion MRI

Purpose: To develop and evaluate a new pulse sequence for highly accelerated distortion-free diffusion MRI (dMRI) by inserting additional echoes without prolonging TR, when generalized slice dithered enhanced resolution (gSlider) radiofrequency encoding is used for volumetric acquisition. Methods: A phase-reversed interleaved multi-echo acquisition (PRIME) was developed for rapid, high-resolution, and distortion-free dMRI, which includes several echoes where the first echo is for target diffusion-weighted imaging (DWI) acquisition with high-resolution and additional echoes are acquired with either lower resolution for 1) high-fidelity field map estimation, 2) phase navigation for shot-to-shot phase correction, 3) motion navigation across diffusion directions, or with high resolution to enable 4) high fidelity diffusion relaxometry acquisitions. The sequence was evaluated on in vivo data acquired from healthy volunteers on clinical and Connectome 2.0 scanners. Results: In vivo experiments demonstrated that 1) high in-plane acceleration (Rin-plane of 5-fold with 2D partial Fourier) was achieved using the high-fidelity field maps estimated from the second echo, which was made at a lower resolution/acceleration to increase its SNR while matching the effective echo spacing of the first readout, 2) high-resolution diffusion relaxometry parameters were estimated from triple-echo PRIME data using a white matter model of multi-TE spherical mean technique (MTE-SMT), and 3) high-fidelity mesoscale DWI at 490 um isotropic resolution was obtained in vivo by capitalizing on the high-performance gradients of the Connectome 2.0 scanner. Conclusion: The proposed PRIME sequence enabled highly accelerated, high-resolution, and distortion-free dMRI using additional echoes without prolonging scan time when gSlider encoding is utilized.

physics.med-ph

Multishot Dual Polarity GRAPPA: Robust Nyquist Ghost Correction for multishot EPI

Purpose: This work aims to develop a robust Nyquist ghost correction method for multishot echo-planar imaging (EPI). The method helps correct challenging Nyquist ghosts, particularly on scanners with high-performance gradients or ultra-high fields. Methods: A method for multishot EPI ghost correction, called multishot dual-polarity GRAPPA (msDPG), is developed by extending the DPG concept to multishot readouts. msDPG employs tailored DPG kernels to address high-order phase differences between two EPI readout polarities, which cannot be fully addressed using linear phase correction (LPC). Advanced regularizers can be readily employed with the proposed msDPG for physiologic inter-shot phase variation correction during reconstruction. Additionally, a calibration refinement method is proposed to improve the quality of the DPG calibration data and enhance reconstruction performance. Results: Phantom and in vivo experiments on scanners with high-performance gradients and ultra-high fields demonstrated that msDPG achieved superior ghost correction performance than LPC, reducing the ghost-to-signal ratio (GSR) by over 50%. Compared to conventional DPG, msDPG provided images with lower noise amplification, particularly for acquisitions with large in-plane acceleration. Consequently, high-fidelity, submillimeter diffusion images were obtained using msDPG with regularized reconstruction. Conclusion: The proposed msDPG provides a robust Nyquist ghost correction method for multishot EPI, enabling submillimeter imaging with improved fidelity.

physics.med-ph

Rapid Whole Brain Motion-robust Mesoscale In-vivo MR Imaging using Multi-scale Implicit Neural Representation

High-resolution whole-brain in vivo MR imaging at mesoscale resolutions remains challenging due to long scan durations, motion artifacts, and limited signal-to-noise ratio (SNR). This study proposes Rotating-view super-resolution (ROVER)-MRI, an unsupervised framework based on multi-scale implicit neural representations (INR), enabling efficient recovery of fine anatomical details from multi-view thick-slice acquisitions. ROVER-MRI employs coordinate-based neural networks to implicitly and continuously encode image structures at multiple spatial scales, simultaneously modeling anatomical continuity and correcting inter-view motion through an integrated registration mechanism. Validation on ex-vivo monkey brain data and multiple in-vivo human datasets demonstrates substantially improved reconstruction performance compared to bicubic interpolation and state-of-the-art regularized least-squares super-resolution reconstruction (LS-SRR) with 2-fold reduction in scan time. Notably, ROVER-MRI achieves an unprecedented whole-brain in-vivo T2-weighted imaging at 180 micron isotropic resolution in only 17 minutes of scan time on a 7T scanner with 22.4% lower relative error compared to LS-SRR. We also demonstrate improved SNR using ROVER-MRI compared to a time-matched 3D GRE acquisition. Quantitative results on several datasets demonstrate better sharpness of the reconstructed images with ROVER-MRI for different super-resolution factors (5 to 11). These findings highlight ROVER-MRI's potential as a rapid, accurate, and motion-resilient mesoscale imaging solution, promising substantial advantages for neuroimaging studies.

eess.IV

χ-sepnet: Deep neural network for magnetic susceptibility source separation

Magnetic susceptibility source separation ($χ$-separation), an advanced quantitative susceptibility mapping (QSM) method, enables the separate estimation of para- and diamagnetic susceptibility source distributions in the brain. The method utilizes reversible transverse relaxation (R2'=R2*-R2) to complement frequency shift information for estimating susceptibility source concentrations, requiring time-consuming data acquisition for R2 in addition R2*. To address this challenge, we develop a new deep learning network, $χ$-sepnet, and propose two deep learning-based susceptibility source separation pipelines, $χ$-sepnet-R2' for inputs with multi-echo GRE and multi-echo spin-echo, and $χ$-sepnet-R2* for input with multi-echo GRE only. $χ$-sepnet is trained using multiple head orientation data that provide streaking artifact-free labels, generating high-quality $χ$-separation maps. The evaluation of the pipelines encompasses both qualitative and quantitative assessments in healthy subjects, and visual inspection of lesion characteristics in multiple sclerosis patients. The susceptibility source-separated maps of the proposed pipelines delineate detailed brain structures with substantially reduced artifacts compared to those from conventional regularization-based reconstruction methods. In quantitative analysis, $χ$-sepnet-R2' achieves the best outcomes followed by $χ$-sepnet-R2*, outperforming the conventional methods. When the lesions of multiple sclerosis patients are assessed, both pipelines report identical lesion characteristics in most lesions ($χ$para: 99.6% and $χ$dia: 98.4% out of 250 lesions). The $χ$-sepnet-R2* pipeline, which only requires multi-echo GRE data, has demonstrated its potential to offer broad clinical and scientific applications, although further evaluations for various diseases and pathological conditions are necessary.

eess.IV

Fast Whole-Brain MR Multi-Parametric Mapping with Scan-Specific Self-Supervised Networks

Quantification of tissue parameters using MRI is emerging as a powerful tool in clinical diagnosis and research studies. The need for multiple long scans with different acquisition parameters prohibits quantitative MRI from reaching widespread adoption in routine clinical and research exams. Accelerated parameter mapping techniques leverage parallel imaging, signal modelling and deep learning to offer more practical quantitative MRI acquisitions. However, the achievable acceleration and the quality of maps are often limited. Joint MAPLE is a recent state-of-the-art multi-parametric and scan-specific parameter mapping technique with promising performance at high acceleration rates. It synergistically combines parallel imaging, model-based and machine learning approaches for joint mapping of T1, T2*, proton density and the field inhomogeneity. However, Joint MAPLE suffers from prohibitively long reconstruction time to estimate the maps from a multi-echo, multi-flip angle (MEMFA) dataset at high resolution in a scan-specific manner. In this work, we propose a faster version of Joint MAPLE which retains the mapping performance of the original version. Coil compression, random slice selection, parameter-specific learning rates and transfer learning are synergistically combined in the proposed framework. It speeds-up the reconstruction time up to 700 times than the original version and processes a whole-brain MEMFA dataset in 21 minutes on average, which originally requires ~260 hours for Joint MAPLE. The mapping performance of the proposed framework is ~2-fold better than the standard and the state-of-the-art evaluated reconstruction techniques on average in terms of the root mean squared error.

q-bio.QM

SSL-QALAS: Self-Supervised Learning for Rapid Multiparameter Estimation in Quantitative MRI Using 3D-QALAS

Purpose: To develop and evaluate a method for rapid estimation of multiparametric T1, T2, proton density (PD), and inversion efficiency (IE) maps from 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) measurements using self-supervised learning (SSL) without the need for an external dictionary. Methods: A SSL-based QALAS mapping method (SSL-QALAS) was developed for rapid and dictionary-free estimation of multiparametric maps from 3D-QALAS measurements. The accuracy of the reconstructed quantitative maps using dictionary matching and SSL-QALAS was evaluated by comparing the estimated T1 and T2 values with those obtained from the reference methods on an ISMRM/NIST phantom. The SSL-QALAS and the dictionary matching methods were also compared in vivo, and generalizability was evaluated by comparing the scan-specific, pre-trained, and transfer learning models. Results: Phantom experiments showed that both the dictionary matching and SSL-QALAS methods produced T1 and T2 estimates that had a strong linear agreement with the reference values in the ISMRM/NIST phantom. Further, SSL-QALAS showed similar performance with dictionary matching in reconstructing the T1, T2, PD, and IE maps on in vivo data. Rapid reconstruction of multiparametric maps was enabled by inferring the data using a pre-trained SSL-QALAS model within 10 s. Fast scan-specific tuning was also demonstrated by fine-tuning the pre-trained model with the target subject's data within 15 min. Conclusion: The proposed SSL-QALAS method enabled rapid reconstruction of multiparametric maps from 3D-QALAS measurements without an external dictionary or labeled ground-truth training data.

eess.IV

Zero-DeepSub: Zero-Shot Deep Subspace Reconstruction for Rapid Multiparametric Quantitative MRI Using 3D-QALAS

Purpose: To develop and evaluate methods for 1) reconstructing 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) time-series images using a low-rank subspace method, which enables accurate and rapid T1 and T2 mapping, and 2) improving the fidelity of subspace QALAS by combining scan-specific deep-learning-based reconstruction and subspace modeling. Methods: A low-rank subspace method for 3D-QALAS (i.e., subspace QALAS) and zero-shot deep-learning subspace method (i.e., Zero-DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time-resolved imaging using 3D-QALAS. Using an ISMRM/NIST system phantom, the accuracy and reproducibility of the T1 and T2 maps estimated using the proposed methods were evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero-DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to 9-fold. Results: Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases and improving precision compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g-factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to 9-fold acceleration with Zero-DeepSub, which enabled whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time. Conclusion: The proposed subspace QALAS along with Zero-DeepSub enabled high fidelity and rapid whole-brain multiparametric quantification and time-resolved imaging.

eess.IV

SubZero: Subspace Zero-Shot MRI Reconstruction

Recently introduced zero-shot self-supervised learning (ZS-SSL) has shown potential in accelerated MRI in a scan-specific scenario, which enabled high-quality reconstructions without access to a large training dataset. ZS-SSL has been further combined with the subspace model to accelerate 2D T2-shuffling acquisitions. In this work, we propose a parallel network framework and introduce an attention mechanism to improve subspace-based zero-shot self-supervised learning and enable higher acceleration factors. We name our method SubZero and demonstrate that it can achieve improved performance compared with current methods in T1 and T2 mapping acquisitions.

eess.IV