SearcharxivSearch

arXiv subjects

Bethany J. Little

Publications and source records attributed to Bethany J. Little.

4 recordsLinked to original sources

Circuit-based leakage-to-erasure conversion in a neutral atom quantum processor

Leakage out of the computational subspace is a major limitation of current state-of-the-art neutral-atom quantum computers and a significant challenge for scalable systems. In a quantum processor with cesium atoms, we demonstrate proof-of-principle circuit-based conversion of leakage errors to erasure errors via Leakage Detection Units (LDUs), which non-destructively map information about the presence or absence of the qubit onto the state of an ancilla. With a standard LDU circuit, we successfully convert leakage errors to erasure errors for all major leakage pathways while preserving the quantum information in the case that no leakage occurred. We benchmark the performance of the LDU using a three-outcome low-loss state detection method and also explore the advantages of three-outcome measurements for LDUs. We find that the LDU detects atom-loss errors with ~93.4% accuracy, limited by technical imperfections of our apparatus. We further compile and execute a SWAP LDU, wherein the roles of the original data atom and ancilla atom are exchanged under the action of the LDU, providing 'free refilling' of atoms in the case of leakage errors. This circuit-based leakage-to-erasure error conversion is a critical component of a neutral-atom quantum processor where the quantum information may significantly outlive the lifetime of any individual atom in the quantum register.

quant-ph

High-Fidelity, Low-Loss State Detection of Alkali-Metal Atoms in Optical Tweezer Traps

We demonstrate discrimination of ground-state hyperfine manifolds of a cesium atom in an optical tweezer using a simple probe beam with 99.91(2)% detection fidelity and 0.9(2)% detection-driven loss of bright state atoms. Our detection infidelity of 0.09(2)% is an order of magnitude better than previously published low-loss readout results for alkali-metal atoms in optical tweezers. Our low atom loss and high-fidelity state detection eliminates the extra depumping mechanism due to population transfer between excited-state sublevels through V-type stimulated Raman transitions caused by the trap laser when the probe laser is present. In this work, complex optical systems and stringent vacuum pressures are not required.

quant-ph

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors are the active pumps -- typically ion pumps -- required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. We present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; our vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate the package maintains a pressure of better than $2\times10^{-7}$ Torr. This result will significantly impact the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

physics.atom-ph

Femtometer Displacement Resolution with Phase-Insensitive Doppler Sensing

The measurement of extremely small displacements is of utmost importance, both for fundamental studies [1-4], and practical applications [5-7]. One way to estimate a small displacement is to measure the Doppler shift generated in light reflected off an object moving with a known periodic frequency. This remote sensing technique converts a displacement measurement into a frequency measurement, and has been considerably successful [8-14]. The displacement sensitivity of this technique is limited by the Doppler frequency noise floor and by the velocity of the moving object. Other primary limitations are hours of integration time [12,13] and optimal operation only in a narrow Doppler frequency range. Here we show a sensitive device capable of measuring $μ$Hz/$\sqrt{\text{Hz}}$ Doppler frequency shifts corresponding to tens of fm displacements for a mirror oscillating at 2 Hz. While the Doppler shift measured is comparable to other techniques [12.13], the position sensitivity is orders of magnitude better, and operates over several orders of magnitude of Doppler frequency range. In addition, unlike other techniques which often rely on interferometric methods, our device is phase insensitive, making it unusually robust to noise.

physics.ins-det