Searcharxiv⌕ Search

arXiv subjects

Beverly J. LaMarr

Publications and source records attributed to Beverly J. LaMarr.

8 recordsLinked to original sources

High-speed, low-noise, multi-megapixel CCDs for next generation X-ray observatories

Next generation X-ray observatories require fast, low-noise, low-power, multi-megapixel imaging spectrometers. To meet these demands, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in partnership with the MIT Kavli Institute and MIT Lincoln Laboratory (MIT-LL), is developing multi-channel X-ray charge-coupled devices (CCDs) and fast readout architectures. We report the energy resolution and noise performance achieved with a full-scale (1440x1440-pixel), 16-channel, front-illuminated MIT-LL CCD detector developed for the Advanced X-ray Imaging Satellite (AXIS) concept, the CCID-100, read out using two Multi-Channel Readout Chip (MCRC) V1 application-specific integrated circuit (ASIC) chips in the new Stanford CCID-100 test setup. We describe an automated method for bias optimization on each CCD channel, and integrated debugging features of the front-end ASIC and readout system. The demonstrated performance confirms that these systems can meet the speed and noise requirements of future strategic X-ray missions.

astro-ph.IM↗

High-statistics simulations of NewAthena WFI background using Geant4

The observation of hot gas structures is one science goal of the Wide Field Imager (WFI) on ESA's NewAthena X-ray observatory. Because the measurement of these faint diffuse sources is limited by background from cosmic ray particle interactions within the instrument, understanding and reducing this background is critical. To this end, we employ a two-pronged approach, performing high-fidelity Geant4 simulations on both detailed, realistic geometry models as well as complementary simple geometry models. The former can reveal subtle sensitivities of background to details of the instrument design. The latter allows for fast iteration, useful in guiding and understanding the larger simulations. We show how we leverage High Performance Computing (HPC) resources to achieve simultaneously high throughput and fast time to result. We discuss our recent results, which are applicable not only to WFI, but also other X-ray missions.

astro-ph.IM↗

Fast, low-noise CCD systems for future strategic X-ray missions

Future strategic X-ray missions, such as those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and noise capabilities required by such programs, our Stanford team, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing enhanced X-ray charge-coupled devices (CCDs) and readout systems that leverage tailored application-specific integrated circuits (ASICs). Here, we report the energy resolution and noise performance achieved using some of the latest MIT-LL CCDs in conjunction with Stanford-developed Multi-Channel Readout Chip (MCRC) ASICs. Additionally, we present a new sampling method for simultaneous optimization of the output gate (OG), reset gate (RG), and reset drain (RD) biases which, in combination with new integrated fast summing well (SW) and RG clock operation modes, enables the data rates and noise required for future X-ray telescopes. Finally, we present noise power spectral density (PSD) and waveform analysis methods and posit a physical model for characterizing and understanding output stage noise behavior.

astro-ph.IM↗

RNDR noise modeling in first-generation Single electron Sensitive Readout (SiSeRO) devices

Flagship observatories require single-photon detectors with ultra-fast readout, sub-electron noise performance, and scalable large-format architectures. The X-ray Astronomy and Observational Cosmology group at Stanford, in collaboration with the MIT Kavli Institute and MIT Lincoln Laboratory, is developing readout technologies for next-generation detectors. Prototypes employing Single-electron Sensitive Readout (SiSeRO) amplifiers demonstrate excellent read noise and spectral performance using repetitive non-destructive readout (RNDR), achieving 0.5 e$^-$ noise in under 57 cycles. We have modeled noise for longer RNDR cycles, exploring probabilistic mechanisms such as thermal leakage and impact ionization. Here we present our model results, including statistical limits on dark current-like signals. Maturation of SiSeRO technology will improve detector performance at soft X-ray energies, addressing technology gaps for future X-ray and UV/visible/near-IR observatories.

astro-ph.IM↗

Fast, low noise CCD systems for future strategic x-ray missions

Future strategic X-ray missions, such as the Advanced X-ray Imaging Satellite (AXIS) and those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and noise capabilities required by such programs, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing readout systems that leverage the high speed, low noise, and low power consumption of application-specific integrated circuit (ASIC) devices. Here, we report the energy resolution and noise performance achieved using MIT-LL AXIS prototype charge-coupled device (CCD) detectors in conjunction with Stanford-developed Multi-Channel Readout Chip (MCRC) ASICs. Additionally, we present a new sampling method for simultaneous optimization of the output gate (OG), reset gate (RG), and reset drain (RD) biases which, in combination with new integrated fast summing well (SW) and RG clock operation modes, enables the data rates required of future X-ray telescopes.

astro-ph.IM↗

Ground calibration plans for the AXIS high speed camera

The Advanced X-ray Imaging Satellite (AXIS), an astrophysics NASA probe mission currently in phase A, will provide high-throughput, high-spatial resolution X-ray imaging in the 0.3 to 10 keV band. We report on the notional ground calibration plan for the High Speed Camera on AXIS, which is being developed at the MIT Kavli Institute for Astrophysics and Space Research using state-of-the-art CCDs provided by MIT Lincoln Laboratory in combination with an integrated, high-speed ASIC readout chip from Stanford University. AXIS camera ground calibration draws on previous experience with X-ray CCD focal plans, in particular Chandra/ACIS and Suzaku/XIS, utilizing mono-energetic X-ray line sources to measure spectral resolution and quantum efficiency. Relative quantum efficiency of the CCDs will be measured against an sCMOS device, with known absolute calibration from synchrotron measurements. We walk through the envisioned CCD calibration pipeline and we discuss the observatory-level science and calibration requirements and how they inform the camera calibration.

astro-ph.IM↗

Understanding the effects of charge diffusion in next-generation soft X-ray imagers

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.

astro-ph.IM↗

Measurement and simulation of charge diffusion in a small-pixel charge-coupled device

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packets. We investigate consequences for sensor performance, reporting charge diffusion measurements in a fully-depleted, 50um thick, back-illuminated CCD with 8um pixels. We are able to measure the size distributions of charge packets produced by 5.9 keV and 1.25 keV X-rays in this device. We find that individual charge packets exhibit a gaussian spatial distribution, and determine the frequency distribution of event widths for a range of internal electric field strength levels. We find a standard deviation for the largest charge packets, which occur near the entrance window, of 3.9um. We show that the shape of the event width distribution provides a clear indicator of full depletion and infer the relationship between event width and interaction depth. We compare measured width distributions to simulations. We compare traditional, 'sum-above-threshold' algorithms for event amplitude determination to 2D gaussian fitting of events and find better spectroscopic performance with the former for 5.9 keV events and comparable results at 1.25 keV. The reasons for this difference are discussed. We point out the importance of read noise driven detection thresholds in spectral resolution, and note that the derived read noise requirements for mission concepts such as AXIS and Lynx may be too lax to meet spectral resolution requirements. While we report measurements made with a CCD, we note that they have implications for the performance of high aspect-ratio silicon active pixel sensors as well.

astro-ph.IM↗