SearcharxivSearch

arXiv subjects

Bingze Dai

Publications and source records attributed to Bingze Dai.

3 recordsLinked to original sources

Pyramid Self-Contrastive Learning for Single-shot Test-time Ultrasound Image Denoising

The inherent electronic and speckle noise complicates clinical interpretation of ultrasound images. Conventional denoising methods rely on explicit noise assumptions whose validity diminishes under composite noise conditions. Learning-based methods are usually pretrained in a limited image domain using a labeled dataset, which implies inevitable domain shift in complex in vivo environments. This study proposes a Pyramid Self-Contrastive Learning (PSCL) framework for test-time ultrasound image denoising without pretraining. Given multiple noisy samples from only one-shot imaging, PSCL disentangles anatomical similarity and noise randomness into separate pyramid latent spaces. The clean image is then decoded from the anatomy space while discarding the noise space. We first apply PSCL to synthetic aperture ultrasound (SAU), where an Aperture-to-Aperture loop serves as a self-supervised proxy task to ensure denoising fidelity. Simulation experiments, including noise levels from 0 to 30 dB and inclusion geometries from simple to complex, demonstrated improvements of 69.3% in SNR and 34.4% in CNR. The in vivo results showed 84.8% SNR and 25.7% CNR gains using only two aperture data of the heart in six echocardiographic views, liver, and kidney. PSCL delivers clear images across diverse imaging targets and configurations, paving the way for more reliable anatomical visualization without domain shift and pretraining costs.

cs.CV

Volumetric Ultrasound via 3D Null Subtraction Imaging with Circular and Spiral Apertures

Volumetric ultrasound imaging faces a fundamental trade-off among image quality, frame rate, and hardware complexity. This study introduces three-dimensional Null Subtraction Imaging (3D NSI), a nonlinear beamforming framework that addresses this trade-off by combining computationally efficient null-subtraction process with multiplexing-aware sparse aperture designs on matrix arrays. We evaluate three apodization configurations: a fully addressed circular aperture and two Fermat's spiral sparse apertures. To overcome channel-sharing constraints common in matrix arrays multiplexed with low-channel-count ultrasound systems, we propose a spiral "no-reuse" apodization that enforces non-overlapping element sets across transmit-receive events. This design resolves multiplexing conflicts and enables up to a 16-fold increase in acquisition volume rate using only 240 active elements on a 1024-element probe. In computer simulations and tissue-mimicking phantom experiments, 3D NSI achieved an average improvement of 36% in azimuthal and elevational resolutions, along with an approximately 20% higher contrast ratio, compared to the conventional Delay-and-Sum (DAS) beamformer under matched transmit/receive configurations. When implemented with the spiral no-reuse aperture, the 3D NSI framework achieved over 1000 volumes per second with a computational load less than three times that of DAS, making it a practical solution for real-time 4D imaging.

eess.IV

Denoising ECG by Adaptive Filter with Empirical Mode Decomposition

Electrocardiogram (ECG) signal is an important physiological signal which contains cardiac information and is the basis to diagnosis cardiac related diseases. In this paper, several innovative and efficient methods based on adaptive filter and empirical mode decomposition (EMD) to denoise ECG signal contaminated by various kinds of noise, including baseline wander (BW), power line interference (PLI), electrode motion artifact (EM) and muscle artifact (MA), are proposed. We first present a novel method based on EMD and adaptive filter for the removal of BW and PLI in ECG signal. We then extend the method to the complex scenario where four most common noises, PLI, BW, EM and MA are present. The proposed Parallel EMD adaptive filter structure yields the best SNR improvement on the MIT-BIH arrhythmia database, corrupted by the four types of noises.

eess.SP