SearcharxivSearch

arXiv subjects

Birgitta Bernhardt

Publications and source records attributed to Birgitta Bernhardt.

11 recordsLinked to original sources

NIR/VIS dual-comb spectroscopy comparing high and low repetition rate regimes

Dual-comb spectroscopy enables broadband analysis of key molecules with unparalleled frequency resolution and exceptional signal-to-noise ratios across various spectral regions. However, fully harnessing its potential for broadband spectroscopy with high sensitivity and spectral resolution depends critically on selecting the appropriate frequency combs with optimized (comb) parameters tailored to specific applications. This study compares dual-comb spectroscopy systems operating at 80 MHz and 1 GHz repetition rates, in the near infrared and visible spectral regions. The 80 MHz system provides high spectral resolution, ideal for resolving complex spectra, showcased with measurements of NH$_3$ vibrational bands and I$_2$ hyperfine transitions. Utilizing phase-locked feed-forward stabilization, the system delivers excellent signal-to-noise ratios but faces limitations in temporal resolution. The free-running 1 GHz system offers superior temporal resolution and compactness, making it suitable for real-time environmental monitoring in laboratory and field settings. A self-correction algorithm advances the high mutual coherence, enabling high-signal-to-noise measurements without additional electronics. With its 1 GHz resolution, it excels in monitoring NH$_3$ transitions or NO$_2$ lines at high speeds. This work highlights the complementary strengths of these systems for high-resolution spectroscopy and real time trace gas sensing.

physics.optics

Streaming Self-Corrected Dual-Comb Spectrometer

We radically simplify coherently averaged dual-comb spectroscopy by introducing a real-time self-correction system: a radio frequency system-on-chip computes each incoming dual-comb interferogram's phase, frequency, and arrival time; calculates changes in the combs' carrier-envelope offset frequency and repetition rate difference; and immediately phase-corrects the incoming interferogram data stream. The algorithm supports up to 0.3 GHz interferogram frequency bandwidth and thus combines fast measurement times (corresponding to high detunings) with broadband optical detection. Using this system, we achieve comb-resolved spectroscopy with Fourier-limited linewidth, coherent averaging over arbitrarily long durations, and high signal-to-noise ratios (e.g., up to 2900 for 150 s averaging time). Iodine and acetylene spectroscopy yield excellent agreement with literature over an optical bandwidth of 10 THz in the visible and near-infrared. Common dual-comb spectroscopy self-correction requires a bright and continuous interferogram train. We lift this requirement by introducing cross-channel correction: the algorithm measures phase fluctuations from a reference channel and predicts and corrects their influence on a signal channel. This enables correcting unstable or intermittent signals (typical, e.g., in field measurements), or low-amplitude signals with amplified phase fluctuations (relevant for nonlinearly upconverted combs). The approach makes instantaneous dual-comb spectroscopy available to everyday applications.

physics.optics

Ultra-resolution photochemical sensing

Photochemistry in the earth's atmosphere is driven by the sun, continuously altering the concentration and spatial distribution of pollutants. Precisely monitoring their atmospheric abundance relies predominantly on optical sensing, which requires the knowledge of exact absorption cross sections. One key pollutant which impacts many photochemical reaction-pathways is formaldehyde. Agreement on formaldehyde absolute absorption cross section remains elusive in the photochemically-relevant ultraviolet spectral region, hampering sensitive concentration tracking. Here, we introduce free-running ultraviolet dual comb spectroscopy, combining high spectral resolution (1 GHz), broad spectral coverage (12 THz), and fast acquisition speed (500 ms), as a novel method for absolute absorption cross section determination with unprecedented fidelity. Within this bandwidth, our method uncovers almost one order of magnitude more rovibrational transitions than detected before which leads to refined rotational constants for high-level quantum simulations of molecular eigenstates. This ultra-resolution method can be generalized to provide a universal tool for fast electronic fingerprinting of atmospherically-relevant species, both for sensing applications and to benchmark improvements of ab-initio quantum theory.

physics.optics

Phase-locked feed forward stabilization for dual comb spectroscopy

Sustained mutual coherence between two combs over extended periods is a prerequisite for dual-comb spectroscopy (DCS), particularly in achieving high-resolution molecular spectroscopy and precise spectral measurements. However, achieving long coherence times remains a challenge for Yb-doped frequency combs. This work introduces an experimental approach for phase-stable DCS using Yb-doped frequency combs at 1.03 $μ$m with a novel feed-forward method, combatting the limitations of mutual coherence. Without relying on computer-based phase correction, we achieve a coherence time of 1000 seconds - three orders of magnitude longer than the current state of the art for DCS. This extended coherence enables time-domain averaging, resulting in a signal-to-noise ratio (SNR) of 2045. We demonstrate high-resolution monitoring of weak overtone transitions in the P and R branches of C${_2}$H${_2}$, with good agreement with HITRAN. The phase-locked multiheterodyne system also enables phase spectrum measurements with a scatter down to 7 mrad. Furthermore, we successfully extend our technique to the visible wavelength range using second harmonic generation, achieving high-resolution spectra of NO${_2}$ with excellent SNR. The method offers high-frequency accuracy and demonstrates the potential of Yb-doped systems for multiplexed metrology, effectively extending the capabilities of DCS as a powerful tool for multi-disciplinary applications.

physics.optics

Ultra-broadband UV/VIS spectroscopy enabled by resonant dispersive wave emission of a frequency comb

We introduce a novel ultra-broadband ultraviolet and visible frequency comb light source covering more than 240 THz by resonant dispersive wave emission in a gas-filled hollow-core fiber waveguide. The light source allows tuning from ~340 nm to 465 nm (645 THz to ~885 THz) with conversion efficiencies of 1.5 %. Ultra-broadband absorption spectroscopy is demonstrated by studying nitrogen dioxide, a molecular species of major atmospheric relevance strongly absorbing across the ultraviolet and visible spectral region. We show that the coherence of the 80 MHz ytterbium fiber-based frequency comb seeding the frequency up-conversion process is conserved, paving the way toward further ultra-broadband (dual) comb spectroscopy across the ultraviolet/visible range.

physics.optics

Broadband near-ultraviolet dual comb spectroscopy

The highly energetic photons of ultraviolet light drive electronic and rovibronic transitions in all molecular species. This radiation is thus a prime tool for strongly selective spectroscopic fingerprinting and real-time environmental monitoring if broad spectral coverage, short acquisition times and high spectral resolution is achieved - requirements that are in mutual competition in traditional applications. As a novel approach with intrinsic potency in all three aspects, here we introduce ultraviolet dual comb spectroscopy using two broadband ultraviolet frequency combs centered at 871 THz and covering a spectral bandwidth of 35.7 THz. Within a 100 us acquisition time window, we obtain rotational state-resolved absorption spectra of formaldehyde, a prototype molecule with high relevance for laser spectroscopy and environmental sciences. This is the first realization of broadband dual comb spectroscopy in the ultraviolet spectral region and a pioneering tool to allow for real-time monitoring of rovibronic transitions.

physics.optics

Ultraviolet Dual Comb Spectroscopy: A Roadmap

Dual Comb Spectroscopy proved its versatile capabilities in molecular fingerprinting in different spectral regions, but not yet in the ultraviolet (UV). Unlocking this spectral window would expand fingerprinting to the electronic energy structure of matter.This will access the prime triggers of photo-chemical reactions with unprecedented spectral resolution. In this research article, we discuss the milestones marking the way to the first UV dual comb spectrometer. We present experimental and simulated studies towards UV dual comb spectroscopy, directly applied to planned absorption measurements of formaldehyde (centered at 343 nm, 3.6 eV) and argon (80 nm, 16 eV). This will enable an unparalleled relative resolution of up to $10^{-9}$ - with a table-top UV source surpassing any synchrotron linked spectrometer by at least two and any grating-based UV spectrometer by up to six orders of magnitude.

physics.optics

Coherent Raman spectro-imaging with laser frequency combs

Optical spectroscopy and imaging of microscopic samples have opened up a wide range of applications throughout the physical, chemical, and biological sciences. High chemical specificity may be achieved by directly interrogating the fundamental or low-lying vibrational energy levels of the compound molecules. Amongst the available prevailing label-free techniques, coherent Raman scattering has the distinguishing features of high spatial resolution down to 200 nm and three-dimensional sectioning. However, combining fast imaging speed and identification of multiple - and possibly unexpected- compounds remains challenging: existing high spectral resolution schemes require long measurement times to achieve broad spectral spans. Here we overcome this difficulty and introduce a novel concept of coherent anti-Stokes Raman scattering (CARS) spectro-imaging with two laser frequency combs. We illustrate the power of our technique with high resolution (4 cm-1) Raman spectra spanning more than 1200 cm-1 recorded within less than 15 microseconds. Furthermore, hyperspectral images combining high spectral (10 cm-1) and spatial (2 micrometers) resolutions are acquired at a rate of 50 pixels per second. Real-time multiplex accessing of hyperspectral images may dramatically expand the range of applications of nonlinear microscopy.

physics.optics

Raman-induced Kerr-effect dual-comb spectroscopy

We report on the first demonstration of nonlinear dual-frequency-comb spectroscopy. In multi-heterodyne femtosecond Raman-induced Kerr-effect spectroscopy, the Raman gain resulting from the coherent excitation of molecular vibrations by a spectrally-narrow pump is imprinted onto the femtosecond laser frequency comb probe spectrum. The birefringence signal induced by the nonlinear interaction of these beams and the sample is heterodyned against a frequency comb local oscillator with a repetition frequency slightly different from that of the comb probe. Such time-domain interference provides multiplex access to the phase and amplitude Raman spectra over a broad spectral bandwidth within a short measurement time. Experimental demonstration, at a spectral resolution of 200 GHz, a measurement time of 293 μs and a sensitivity of 10^-6, is given on liquid samples exhibiting a C-H stretch Raman shift.

physics.optics

Improved Measurement of the Hydrogen 1S - 2S Transition Frequency

We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.

physics.atom-ph

Cavity-enhanced dual-comb spectroscopy

The sensitivity of molecular fingerprinting is dramatically improved when placing the absorbing sample in a high-finesse optical cavity, thanks to the large increase of the effective path-length. As demonstrated recently, when the equidistant lines from a laser frequency comb are simultaneously injected into the cavity over a large spectral range, multiple trace-gases may be identified within a few milliseconds. Analyzing efficiently the light transmitted through the cavity however still remains challenging. Here, a novel approach, cavity-enhanced frequency comb Fourier transform spectroscopy, fully overcomes this difficulty and measures ultrasensitive, broad-bandwidth, high-resolution spectra within a few tens of $μ$s. It could be implemented from the Terahertz to the ultraviolet regions without any need for detector arrays. We recorded, within 18 $μ$s, spectra of the 1.0 $μ$m overtone bands of ammonia spanning 20 nm with 4.5 GHz resolution and a noise-equivalent-absorption at one-second-averaging per spectral element of 3 10^-12 cm^-1Hz^-1/2, thus opening a route to time-resolved spectroscopy of rapidly-evolving single-events.

physics.optics