Searcharxiv⌕ Search

arXiv subjects

Birgitta K. Velthuis

Publications and source records attributed to Birgitta K. Velthuis.

6 recordsLinked to original sources

Feasibility of Continuous Ventricular Volumetric Quantification in Arrhythmias using Real-Time 3D CMR-MOTUS

Conventional cardiovascular magnetic resonance (CMR) cine imaging combines data across multiple heartbeats, an assumption that can fail in arrhythmia because beat-to-beat variation causes motion artifacts and obscures functional heterogeneity. Although 2D real-time cine resolves individual beats, stacked slices are suboptimal for capturing complex 3D cardiac dynamics. We investigated continuous beat-to-beat volumetric quantification in patients with premature ventricular contractions (PVCs) using free-running 3D real-time CMR. CMR-MOTUS was extended to jointly reconstruct time-resolved 3D motion fields and a motion-corrected reference image from continuously acquired data without breath-holding or ECG gating. Data were acquired with a variable-density Cartesian trajectory and either 3D spoiled gradient-echo or balanced steady-state free-precession imaging. Ventricular volumes were obtained by propagating one manual reference-image segmentation through all reconstructed frames. The method was evaluated in a cardiac motion phantom with static ground-truth acquisitions, 10 healthy volunteers, and 10 patients with PVCs; all in vivo scans were performed after contrast administration. Phantom ejection fraction (EF) agreed closely with ground truth (17.86% versus 17.27%). Healthy volunteers showed narrow beat-to-beat EF distributions, whereas patients with PVCs showed broader and sometimes bimodal distributions. Simultaneous ECG recordings supported the temporal correspondence between volume irregularities and PVC episodes. Free-running joint 3D motion-field and image reconstruction enables continuous beat-to-beat volumetric assessment and can reveal functional heterogeneity obscured by gated or heartbeat-averaged methods. Larger studies are required to establish clinical validity and determine its role alongside standard 2D cine analysis.

physics.med-ph↗

The TopCoW Challenge -- Topology-Aware Circle of Willis Segmentation for CT and MR Angiography

The Circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain. Its vascular architecture is believed to influence the risk, severity, and outcome of serious neurovascular diseases. However, characterizing the highly variable CoW anatomy remains a manual and time-consuming expert task. The CoW is commonly imaged by two non-invasive angiographic imaging modalities, magnetic resonance angiography (MRA) and computed tomography angiography (CTA), yet few datasets with annotated CoW anatomy exist, and there have been no established benchmarks for comparing CoW segmentation algorithms. We organized the TopCoW benchmark challenge alongside the release of an annotated CoW dataset with 125 paired MRA and CTA scans from the same patients. Voxel-level annotations for 13 vessel components were created using virtual reality technology and verified by clinical experts. Participants submitted algorithms for CoW segmentation and variant classification, which we evaluated on internal and external test sets comprising 226 scans from over five centers. The benchmark includes voxel-level segmentation, CoW component detection, CoW variant classification, and two clinical application tasks. We received submissions from over 250 participants across six continents. Top-performing teams achieved over 90% Dice scores for CoW segmentation, over 80% F1 scores for detecting key vessel components, and over 70% balanced accuracy in CoW variant classification across nearly all test sets. The best algorithms also supported clinically relevant downstream tasks by accurately classifying fetal-type posterior cerebral arteries and localizing aneurysms in relation to CoW anatomy. This benchmark demonstrated the utility of CoW segmentation algorithms for some downstream clinical applications with explainability.

cs.CV↗

Free-Running Time-Resolved First-Pass Myocardial Perfusion Using a Multi-Scale Dynamics Decomposition: CMR-MOTUS

We present a novel approach for the reconstruction of time-resolved free-running first-pass myocardial perfusion MRI, named CMR-MOTUS. This method builds upon the MR-MOTUS framework and addresses the challenges of a contrast varying reference image. By integrating a low-rank plus sparse (L+S) decomposition, CMR-MOTUS efficiently captures both motion fields and contrast variations. This innovative technique eliminates the need for acquiring a motion-static reference image prior to the examination, thereby reducing examination time and complexity for cardiac MRI examinations. Our results demonstrate that CMR-MOTUS can successfully disentangle different dynamic components, offering high-quality motion fields and motion correct a myocardial first-pass perfusion image series.

physics.med-ph↗

Deep Learning for Automatic Strain Quantification in Arrhythmogenic Right Ventricular Cardiomyopathy

Quantification of cardiac motion with cine Cardiac Magnetic Resonance Imaging (CMRI) is an integral part of arrhythmogenic right ventricular cardiomyopathy (ARVC) diagnosis. Yet, the expert evaluation of motion abnormalities with CMRI is a challenging task. To automatically assess cardiac motion, we register CMRIs from different time points of the cardiac cycle using Implicit Neural Representations (INRs) and perform a biomechanically informed regularization inspired by the myocardial incompressibility assumption. To enhance the registration performance, our method first rectifies the inter-slice misalignment inherent to CMRI by performing a rigid registration guided by the long-axis views, and then increases the through-plane resolution using an unsupervised deep learning super-resolution approach. Finally, we propose to synergically combine information from short-axis and 4-chamber long-axis views, along with an initialization to incorporate information from multiple cardiac time points. Thereafter, to quantify cardiac motion, we calculate global and segmental strain over a cardiac cycle and compute the peak strain. The evaluation of the method is performed on a dataset of cine CMRI scans from 47 ARVC patients and 67 controls. Our results show that inter-slice alignment and generation of super-resolved volumes combined with joint analysis of the two cardiac views, notably improves registration performance. Furthermore, the proposed initialization yields more physiologically plausible registrations. The significant differences in the peak strain, discerned between the ARVC patients and healthy controls suggest that automated motion quantification methods may assist in diagnosis and provide further understanding of disease-specific alterations of cardiac motion.

eess.IV↗

Future Unruptured Intracranial Aneurysm Growth Prediction using Mesh Convolutional Neural Networks

The growth of unruptured intracranial aneurysms (UIAs) is a predictor of rupture. Therefore, for further imaging surveillance and treatment planning, it is important to be able to predict if an UIA is likely to grow based on an initial baseline Time-of-Flight MRA (TOF-MRA). It is known that the size and shape of UIAs are predictors of aneurysm growth and/or rupture. We perform a feasibility study of using a mesh convolutional neural network for future UIA growth prediction from baseline TOF-MRAs. We include 151 TOF-MRAs, with 169 UIAs where 49 UIAs were classified as growing and 120 as stable, based on the clinical definition of growth (>1 mm increase in size in follow-up scan). UIAs were segmented from TOF-MRAs and meshes were automatically generated. We investigate the input of both UIA mesh only and region-of-interest (ROI) meshes including UIA and surrounding parent vessels. We develop a classification model to predict UIAs that will grow or remain stable. The model consisted of a mesh convolutional neural network including additional novel input edge features of shape index and curvedness which describe the surface topology. It was investigated if input edge mid-point co-ordinates influenced the model performance. The model with highest AUC (63.8%) for growth prediction was using UIA meshes with input edge mid-point co-ordinate features (average F1 score = 62.3%, accuracy = 66.9%, sensitivity = 57.3%, specificity = 70.8%). We present a future UIA growth prediction model based on a mesh convolutional neural network with promising results.

eess.IV↗

Variational Autoencoders with a Structural Similarity Loss in Time of Flight MRAs

Time-of-Flight Magnetic Resonance Angiographs (TOF-MRAs) enable visualization and analysis of cerebral arteries. This analysis may indicate normal variation of the configuration of the cerebrovascular system or vessel abnormalities, such as aneurysms. A model would be useful to represent normal cerebrovascular structure and variabilities in a healthy population and to differentiate from abnormalities. Current anomaly detection using autoencoding convolutional neural networks usually use a voxelwise mean-error for optimization. We propose optimizing a variational-autoencoder (VAE) with structural similarity loss (SSIM) for TOF-MRA reconstruction. A patch-trained 2D fully-convolutional VAE was optimized for TOF-MRA reconstruction by comparing vessel segmentations of original and reconstructed MRAs. The method was trained and tested on two datasets: the IXI dataset, and a subset from the ADAM challenge. Both trained networks were tested on a dataset including subjects with aneurysms. We compared VAE optimization with L2-loss and SSIM-loss. Performance was evaluated between original and reconstructed MRAs using mean square error, mean-SSIM, peak-signal-to-noise-ratio and dice similarity index (DSI) of segmented vessels. The L2-optimized VAE outperforms SSIM, with improved reconstruction metrics and DSIs for both datasets. Optimization using SSIM performed best for visual image quality, but with discrepancy in quantitative reconstruction and vascular segmentation. The larger, more diverse IXI dataset had overall better performance. Reconstruction metrics, including SSIM, were lower for MRAs including aneurysms. A SSIM-optimized VAE improved the visual perceptive image quality of TOF-MRA reconstructions. A L2-optimized VAE performed best for TOF-MRA reconstruction, where the vascular segmentation is important. SSIM is a potential metric for anomaly detection of MRAs.

eess.IV↗