Boyang Pan

Publications and source records attributed to Boyang Pan.

5 recordsLinked to original sources

Leveraging High-Activity Post-Therapeutic I-131 Scans for Deep Learning Reconstruction of Extremely Sparse Planar Images in Differentiated Thyroid Cancer

Background: Diagnostic I-131 whole-body planar imaging in differentiated thyroid cancer (DTC) is count-limited by low administered activity, and quality worsens under rapid acquisition. Models trained on such data struggle because their targets lack photon statistics. Purpose: To test whether high-quality post-therapeutic (PT) I-131 scans can serve as superior training references for enhancing sparse diagnostic planar images, using transfer learning and input-image addition. Methods: In this single-center prospective study, 111 patients were enrolled in PT training (n = 19), diagnostic follow-up (FU) training (n = 58), and FU paired test (n = 34) cohorts. Five Restormer-based models were trained: FU_DLx2 on FU labels; PT_DLx2 transfer-learned on PT data; PT_DLx1+ and PT_DLx2+ with input-image addition; PT_DLx6 as a PT-only reference. Test-time processing used two-step denormalization and Poisson re-scaling to preserve noise statistics. Quality was assessed by PSNR, SSIM, and a blinded dual-reader evaluation of all 34 test-cohort patients. Results: PT_DLx2 achieved the highest PSNR (34.4 +/- 3.6 dB) and SSIM (0.81 +/- 0.07). PT_DLx1+ and PT_DLx2+ were comparable (33.8 and 33.3 dB; SSIM 0.80). FU_DLx2 ranked below the unprocessed fast scan (30.3 vs. 32.0 dB; 0.76 vs. 0.79). Subjectively, PT_DLx2+ scored highest in image quality (4.54 +/- 0.60) and diagnostic confidence (4.54 +/- 0.60), surpassing the reference standard (4.19 +/- 0.83 and 4.31 +/- 0.81; P = 0.005 and P = 0.008). FU_DLx2 and PT_DLx6 scored lowest. Conclusion: Count-rich PT scans provide effective training priors for reconstructing extremely sparse images. Input-image addition and cross-domain transfer learning from PT data outperformed direct training on count-limited diagnostic data, supporting 2x scan acceleration with quality matching or exceeding the unaccelerated standard scan for selected PT-derived configurations.

eess.IV↗

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

eess.IV↗

Removing Motion Artifact in MRI by Using a Perceptual Loss Driven Deep Learning Framework

Purpose: Deep learning-based MRI artifact correction methods often demonstrate poor generalization to clinical data. This limitation largely stems from the inability of deep learning models in reliably distinguishing motion artifacts from true anatomical structures, due to insufficient awareness of artifact characteristics. To address this challenge, we proposed PERCEPT-Net, a deep learning framework that enhances structure preserving and suppresses artifact through dedicated perceptual supervision.Method: PERCEPT-Net is built on a residual U-Net backbone and incorporates three auxiliary components. The first multi-scale recovery module is designed to preserve both global anatomical context and fine structural details, while the second dual attention mechanisms further improve performance by prioritizing clinically relevant features. At the core of the framework is the third Motion Perceptual Loss (MPL), an artifact-aware perceptual supervision strategy that learns generalized representations of MRI motion artifacts, enabling the model to effectively suppress them while maintaining anatomical fidelity. The model is trained on a hybrid dataset comprising both real and simulated paired volumes, and its performance is validated on a prospective test set using a combination of quantitative metrics and qualitative assessments by experienced radiologists.Result: PERCEPT-Net outperformed state-of-the-art methods on clinical data. Ablation studies identified the Motion Perceptual Loss as the primary contributor to this performance, yielding significant improvements in structural consistency and tissue contrast, as reflected by higher SSIM and PSNR values. These findings were further corroborated by radiologist evaluations, which demonstrated significantly higher diagnostic confidence in the corrected volumes.

cs.CV↗

Deep Learning Superresolution for 7T Knee MR Imaging: Impact on Image Quality and Diagnostic Performance

Background: Deep learning superresolution (SR) may enhance musculoskeletal MR image quality, but its diagnostic value in knee imaging at 7T is unclear. Objectives: To compare image quality and diagnostic performance of SR, low-resolution (LR), and high-resolution (HR) 7T knee MRI. Methods: In this prospective study, 42 participants underwent 7T knee MRI with LR (0.8*0.8*2 mm3) and HR (0.4*0.4*2 mm3) sequences. SR images were generated from LR data using a Hybrid Attention Transformer model. Three radiologists assessed image quality, anatomic conspicuity, and detection of knee pathologies. Arthroscopy served as reference in 10 cases. Results: SR images showed higher overall quality than LR (median score 5 vs 4, P<.001) and lower noise than HR (5 vs 4, P<.001). Visibility of cartilage, menisci, and ligaments was superior in SR and HR compared to LR (P<.001). Detection rates and diagnostic performance (sensitivity, specificity, AUC) for intra-articular pathology were similar across image types (P>=.095). Conclusions: Deep learning superresolution improved subjective image quality in 7T knee MRI but did not increase diagnostic accuracy compared with standard LR imaging.

eess.IV↗

AutoLugano: A Deep Learning Framework for Fully Automated Lymphoma Segmentation and Lugano Staging on FDG-PET/CT

Purpose: To develop a fully automated deep learning system, AutoLugano, for end-to-end lymphoma classification by performing lesion segmentation, anatomical localization, and automated Lugano staging from baseline FDG-PET/CT scans. Methods: The AutoLugano system processes baseline FDG-PET/CT scans through three sequential modules:(1) Anatomy-Informed Lesion Segmentation, a 3D nnU-Net model, trained on multi-channel inputs, performs automated lesion detection (2) Atlas-based Anatomical Localization, which leverages the TotalSegmentator toolkit to map segmented lesions to 21 predefined lymph node regions using deterministic anatomical rules; and (3) Automated Lugano Staging, where the spatial distribution of involved regions is translated into Lugano stages and therapeutic groups (Limited vs. Advanced Stage).The system was trained on the public autoPET dataset (n=1,007) and externally validated on an independent cohort of 67 patients. Performance was assessed using accuracy, sensitivity, specificity, F1-scorefor regional involvement detection and staging agreement. Results: On the external validation set, the proposed model demonstrated robust performance, achieving an overall accuracy of 88.31%, sensitivity of 74.47%, Specificity of 94.21% and an F1-score of 80.80% for regional involvement detection,outperforming baseline models. Most notably, for the critical clinical task of therapeutic stratification (Limited vs. Advanced Stage), the system achieved a high accuracy of 85.07%, with a specificity of 90.48% and a sensitivity of 82.61%.Conclusion: AutoLugano represents the first fully automated, end-to-end pipeline that translates a single baseline FDG-PET/CT scan into a complete Lugano stage. This study demonstrates its strong potential to assist in initial staging, treatment stratification, and supporting clinical decision-making.

cs.CV↗