Searcharxiv⌕ Search

arXiv subjects

Bram van Ginneken

Publications and source records attributed to Bram van Ginneken.

At least 19 recordsLinked to original sources

Designing UNICORN: a Unified Benchmark for Imaging in Computational Pathology, Radiology, and Natural Language

Foundation models are changing the way we develop medical artificial intelligence. By learning broadly generalizable features across diverse data modalities, a single model can be rapidly adapted to address multiple modalities and tasks with minimal supervision. This potential comes with the urgent need to reliably benchmark, understand and compare the performance and clinical impact of foundation models across data modalities and clinical tasks. We introduce UNICORN, a fundamentally new benchmarking concept for medical foundation models. UNICORN brings four main contributions to medical artificial intelligence. First, a framework that enables a one-to-many benchmarking approach, where a single foundation model is tested across multiple tasks and data modalities. Here, we populate it with 20 tasks across radiology, pathology, and clinical text, covering classification, detection, segmentation, regression, and vision-language generation. Second, a publicly available evaluation platform that implements, for the first time, a two-step approach to run foundation models for data encoding followed by custom task-specific adaptation via few-shot learning and linear probing mechanisms. Third, we create a meta-model that combines state-of-the-art foundation models in pathology, radiology and language with novel task-specific adapters that address all UNICORN tasks, which we refer to as Unicorn Model-0 (UM-0). Finally, we design a novel UNICORN score to benchmark and compare model performance across all tasks. We present the results of UM-0 using sequestered test data from over 2,400 patients, 3,700 vision cases, and 2,400 clinical reports from 17 institutions across eight countries, spanning eight anatomical regions and four imaging modalities. Data, baselines, and evaluation platform are publicly accessible at unicorn.grand-challenge.org.

cs.CV↗

Medical Imaging AI Competitions Lack Fairness

Benchmarking competitions are central to the development of artificial intelligence (AI) in medical imaging, defining performance standards and shaping methodological progress. However, it remains unclear whether these benchmarks provide data that are sufficiently representative, accessible, and reusable to support clinically meaningful AI. In this work, we assess fairness along two complementary dimensions: (1) whether challenge datasets capture the diversity of real-world clinical data, and (2) whether they are accessible and legally reusable in line with the FAIR principles. To address this question, we conducted a large-scale systematic study of 249 biomedical image analysis challenges comprising 458 tasks across 19 imaging modalities. Our findings reveal limited representation across challenge datasets with respect to geographic location, imaging modalities, and problem types, raising concerns about how well current benchmarks reflect real-world clinical diversity. Despite their widespread influence, challenge datasets were frequently constrained by restrictive or ambiguous access conditions, inconsistent or non-compliant licensing practices, and incomplete documentation, limiting reproducibility and long-term reuse. Together, these shortcomings expose foundational fairness limitations in our benchmarking ecosystem and highlight a disconnect between leaderboard success and clinical relevance.

cs.CV↗

Robust Renal Mass Segmentation on CT: A Validation Study of an AI-Based Framework

Renal mass segmentation has important potential to enhance the clinical workflow, especially in settings requiring quantitative assessments. Kidney volume could serve as an important biomarker for renal diseases, with changes in volume correlating directly with kidney function. Currently, clinical practice often relies on subjective visual assessment for evaluating kidney size and kidney lesions, including tumors and cysts, which are typically staged based on diameter, volume, and anatomical location. To support a more objective and reproducible approach, this research aims to develop a robust, thoroughly validated renal mass segmentation algorithm, named Renal-Net. We employ publicly available training datasets and leverage the state-of-the-art medical image segmentation framework nnU-Net. Validation is conducted using both proprietary and public test datasets, with segmentation performance quantified by Dice coefficient and the 95th percentile Hausdorff distance. Furthermore, we analyze robustness across subgroups based on patient sex, age, CT contrast phases, and tumor histologic subtypes. Our findings demonstrate that our segmentation algorithm, trained exclusively on publicly available data, generalizes effectively to external test sets and outperforms existing state-of-the-art models across all tested datasets. Subgroup analyses reveal consistent high performance, indicating strong robustness and reliability. The developed algorithm and associated code are publicly accessible at https://github.com/DIAGNijmegen/oncology-kidney-abnormality-segmentation.

cs.CV↗

Benchmarking Foundation Models for Renal Lesion Stratification in CT

The rapid proliferation of open-source medical foundation models (FMs) raises a practical question: how well do their pre-trained representations transfer to clinically relevant but data-scarce classification tasks? Particularly in CT-based renal lesion classification, a push toward greater generalizability would be meaningful, as the field is constrained by inherently limited training data. We addressed this through a benchmark of three medical FMs on this specific task. This six-class problem spans common entities like cysts and clear cell renal cell carcinoma, alongside rare subtypes. Using a frozen feature-probing protocol, we compared FM embeddings against a handcrafted radiomics classifier and a 3D ResNet-50 trained from scratch. Models were trained on a composite dataset of 2,854 lesions and evaluated on an external test set of 234 lesions from The Cancer Imaging Archive. Our results reveal two key findings. First, FM performance (AUC 0.70-0.77) matched the from-scratch ResNet (AUC 0.72) while drastically reducing hardware demand, requiring only seconds on a CPU after feature extraction. However, the conventional radiomics baseline significantly outperformed all deep learning approaches, achieving an AUC of 0.88 (all p $\leq$ 0.002). This suggests that current generalist FM embeddings do not yet capture the fine-grained texture and shape heterogeneity driving histological subtype discrimination. Despite their potential in data-scarce settings, medical FMs did not surpass established models for renal lesion stratification, leaving radiomics as the current state-of-the-art.

cs.CV↗

TotalRegistrator: Towards a Lightweight Foundation Model for CT Image Registration

Image registration is a fundamental technique in the analysis of longitudinal and multi-phase CT images within clinical practice. However, most existing methods are tailored for single-organ applications, limiting their generalizability to other anatomical regions. This work presents TotalRegistrator, an image registration framework capable of aligning multiple anatomical regions simultaneously using a standard UNet architecture and a novel field decomposition strategy. The model is lightweight, requiring only 11GB of GPU memory for training. To train and evaluate our method, we constructed a large-scale longitudinal dataset comprising 695 whole-body (thorax-abdomen-pelvic) paired CT scans from individual patients acquired at different time points. We benchmarked TotalRegistrator against a generic classical iterative algorithm and a recent foundation model for image registration. To further assess robustness and generalizability, we evaluated our model on three external datasets: the public thoracic and abdominal datasets from the Learn2Reg challenge, and a private multiphase abdominal dataset from a collaborating hospital. Experimental results on the in-house dataset show that the proposed approach generally surpasses baseline methods in multi-organ abdominal registration, with a slight drop in lung alignment performance. On out-of-distribution datasets, it achieved competitive results compared to leading single-organ models, despite not being fine-tuned for those tasks, demonstrating strong generalizability. The source code will be publicly available at: https://github.com/DIAGNijmegen/oncology_image_registration.git.

eess.IV↗

Leveraging Open-Source Large Language Models for Clinical Information Extraction in Resource-Constrained Settings

Medical reports contain rich clinical information but are often unstructured and written in domain-specific language, posing challenges for information extraction. While proprietary large language models (LLMs) have shown promise in clinical natural language processing, their lack of transparency and data privacy concerns limit their utility in healthcare. This study therefore evaluates nine open-source generative LLMs on the DRAGON benchmark, which includes 28 clinical information extraction tasks in Dutch. We developed \texttt{llm\_extractinator}, a publicly available framework for information extraction using open-source generative LLMs, and used it to assess model performance in a zero-shot setting. Several 14 billion parameter models, Phi-4-14B, Qwen-2.5-14B, and DeepSeek-R1-14B, achieved competitive results, while the bigger Llama-3.3-70B model achieved slightly higher performance at greater computational cost. Translation to English prior to inference consistently degraded performance, highlighting the need of native-language processing. These findings demonstrate that open-source LLMs, when used with our framework, offer effective, scalable, and privacy-conscious solutions for clinical information extraction in low-resource settings.

cs.CL↗

In the Picture: Medical Imaging Datasets, Artifacts, and their Living Review

Datasets play a critical role in medical imaging research, yet issues such as label quality, shortcuts, and metadata are often overlooked. This lack of attention may harm the generalizability of algorithms and, consequently, negatively impact patient outcomes. While existing medical imaging literature reviews mostly focus on machine learning (ML) methods, with only a few focusing on datasets for specific applications, these reviews remain static -- they are published once and not updated thereafter. This fails to account for emerging evidence, such as biases, shortcuts, and additional annotations that other researchers may contribute after the dataset is published. We refer to these newly discovered findings of datasets as research artifacts. To address this gap, we propose a living review that continuously tracks public datasets and their associated research artifacts across multiple medical imaging applications. Our approach includes a framework for the living review to monitor data documentation artifacts, and an SQL database to visualize the citation relationships between research artifact and dataset. Lastly, we discuss key considerations for creating medical imaging datasets, review best practices for data annotation, discuss the significance of shortcuts and demographic diversity, and emphasize the importance of managing datasets throughout their entire lifecycle. Our demo is publicly available at http://inthepicture.itu.dk/.

cs.CV↗

SlicerNNInteractive: A 3D Slicer extension for nnInteractive

SlicerNNInteractive integrates nnInteractive, a state-of-the-art promptable deep learning-based framework for 3D image segmentation, into the widely used 3D Slicer platform. Our extension implements a client-server architecture that decouples computationally intensive model inference from the client-side interface. Therefore, SlicerNNInteractive eliminates heavy hardware constraints on the client-side and enables better operating system compatibility than existing plugins for nnInteractive. Running both the client and server-side on a single machine is also possible, offering flexibility across different deployment scenarios. The extension provides an intuitive user interface with all interaction types available in the original framework (point, bounding box, scribble, and lasso prompts), while including a comprehensive set of keyboard shortcuts for efficient workflow.

eess.IV↗

Divide to Conquer: A Field Decomposition Approach for Multi-Organ Whole-Body CT Image Registration

Image registration is an essential technique for the analysis of Computed Tomography (CT) images in clinical practice. However, existing methodologies are predominantly tailored to a specific organ of interest and often exhibit lower performance on other organs, thus limiting their generalizability and applicability. Multi-organ registration addresses these limitations, but the simultaneous alignment of multiple organs with diverse shapes, sizes and locations requires a highly complex deformation field with a multi-layer composition of individual deformations. This study introduces a novel field decomposition approach to address the high complexity of deformations in multi-organ whole-body CT image registration. The proposed method is trained and evaluated on a longitudinal dataset of 691 patients, each with two CT images obtained at distinct time points. These scans fully encompass the thoracic, abdominal, and pelvic regions. Two baseline registration methods are selected for this study: one based on optimization techniques and another based on deep learning. Experimental results demonstrate that the proposed approach outperforms baseline methods in handling complex deformations in multi-organ whole-body CT image registration.

cs.CV↗

Attenuation artifact detection and severity classification in intracoronary OCT using mixed image representations

In intracoronary optical coherence tomography (OCT), blood residues and gas bubbles cause attenuation artifacts that can obscure critical vessel structures. The presence and severity of these artifacts may warrant re-acquisition, prolonging procedure time and increasing use of contrast agent. Accurate detection of these artifacts can guide targeted re-acquisition, reducing the amount of repeated scans needed to achieve diagnostically viable images. However, the highly heterogeneous appearance of these artifacts poses a challenge for the automated detection of the affected image regions. To enable automatic detection of the attenuation artifacts caused by blood residues and gas bubbles based on their severity, we propose a convolutional neural network that performs classification of the attenuation lines (A-lines) into three classes: no artifact, mild artifact and severe artifact. Our model extracts and merges features from OCT images in both Cartesian and polar coordinates, where each column of the image represents an A-line. Our method detects the presence of attenuation artifacts in OCT frames reaching F-scores of 0.77 and 0.94 for mild and severe artifacts, respectively. The inference time over a full OCT scan is approximately 6 seconds. Our experiments show that analysis of images represented in both Cartesian and polar coordinate systems outperforms the analysis in polar coordinates only, suggesting that these representations contain complementary features. This work lays the foundation for automated artifact assessment and image acquisition guidance in intracoronary OCT imaging.

cs.CV↗

Artificial Intelligence to Assess Dental Findings from Panoramic Radiographs -- A Multinational Study

Dental panoramic radiographs (DPRs) are widely used in clinical practice for comprehensive oral assessment but present challenges due to overlapping structures and time constraints in interpretation. This study aimed to establish a solid baseline for the AI-automated assessment of findings in DPRs by developing, evaluating an AI system, and comparing its performance with that of human readers across multinational data sets. We analyzed 6,669 DPRs from three data sets (the Netherlands, Brazil, and Taiwan), focusing on 8 types of dental findings. The AI system combined object detection and semantic segmentation techniques for per-tooth finding identification. Performance metrics included sensitivity, specificity, and area under the receiver operating characteristic curve (AUC-ROC). AI generalizability was tested across data sets, and performance was compared with human dental practitioners. The AI system demonstrated comparable or superior performance to human readers, particularly +67.9% (95% CI: 54.0%-81.9%; p < .001) sensitivity for identifying periapical radiolucencies and +4.7% (95% CI: 1.4%-8.0%; p = .008) sensitivity for identifying missing teeth. The AI achieved a macro-averaged AUC-ROC of 96.2% (95% CI: 94.6%-97.8%) across 8 findings. AI agreements with the reference were comparable to inter-human agreements in 7 of 8 findings except for caries (p = .024). The AI system demonstrated robust generalization across diverse imaging and demographic settings and processed images 79 times faster (95% CI: 75-82) than human readers. The AI system effectively assessed findings in DPRs, achieving performance on par with or better than human experts while significantly reducing interpretation time. These results highlight the potential for integrating AI into clinical workflows to improve diagnostic efficiency and accuracy, and patient management.

cs.CV↗

MRSegmentator: Multi-Modality Segmentation of 40 Classes in MRI and CT

Purpose: To develop and evaluate a deep learning model for multi-organ segmentation of MRI scans. Materials and Methods: The model was trained on 1,200 manually annotated 3D axial MRI scans from the UK Biobank, 221 in-house MRI scans, and 1228 CT scans from the TotalSegmentator dataset. A human-in-the-loop annotation workflow was employed, leveraging cross-modality transfer learning from an existing CT segmentation model to segment 40 anatomical structures. The annotation process began with a model based on transfer learning between CT and MR, which was iteratively refined based on manual corrections to predicted segmentations. The model's performance was evaluated on MRI examinations obtained from the German National Cohort (NAKO) study (n=900) from the AMOS22 dataset (n=60) and from the TotalSegmentator-MRI test data (n=29). The Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD) were used to assess segmentation quality, stratified by organ and scan type. The model and its weights will be open-sourced. Results: MRSegmentator demonstrated high accuracy for well-defined organs (lungs: DSC 0.96, heart: DSC 0.94) and organs with anatomic variability (liver: DSC 0.96, kidneys: DSC 0.95). Smaller structures showed lower accuracy (portal/splenic veins: DSC 0.64, adrenal glands: DSC 0.69). On external validation using NAKO data, mean DSC ranged from 0.85 $\pm$ 0.08 for T2-HASTE to 0.91 $\pm$ 0.05 for in-phase sequences. The model generalized well to CT, achieving mean DSC of 0.84 $\pm$ 0.11 on AMOS CT data. Conclusion: MRSegmentator accurately segments 40 anatomical structures in MRI across diverse datasets and imaging protocols, with additional generalizability to CT images. This open-source model will provide a valuable tool for automated multi-organ segmentation in medical imaging research. It can be downloaded from https://github.com/hhaentze/MRSegmentator.

eess.IV↗

Lumbar spine segmentation in MR images: a dataset and a public benchmark

This paper presents a large publicly available multi-center lumbar spine magnetic resonance imaging (MRI) dataset with reference segmentations of vertebrae, intervertebral discs (IVDs), and spinal canal. The dataset includes 447 sagittal T1 and T2 MRI series from 218 patients with a history of low back pain and was collected from four different hospitals. An iterative data annotation approach was used by training a segmentation algorithm on a small part of the dataset, enabling semi-automatic segmentation of the remaining images. The algorithm provided an initial segmentation, which was subsequently reviewed, manually corrected, and added to the training data. We provide reference performance values for this baseline algorithm and nnU-Net, which performed comparably. Performance values were computed on a sequestered set of 39 studies with 97 series, which were additionally used to set up a continuous segmentation challenge that allows for a fair comparison of different segmentation algorithms. This study may encourage wider collaboration in the field of spine segmentation and improve the diagnostic value of lumbar spine MRI.

eess.IV↗

Understanding metric-related pitfalls in image analysis validation

Validation metrics are key for the reliable tracking of scientific progress and for bridging the current chasm between artificial intelligence (AI) research and its translation into practice. However, increasing evidence shows that particularly in image analysis, metrics are often chosen inadequately in relation to the underlying research problem. This could be attributed to a lack of accessibility of metric-related knowledge: While taking into account the individual strengths, weaknesses, and limitations of validation metrics is a critical prerequisite to making educated choices, the relevant knowledge is currently scattered and poorly accessible to individual researchers. Based on a multi-stage Delphi process conducted by a multidisciplinary expert consortium as well as extensive community feedback, the present work provides the first reliable and comprehensive common point of access to information on pitfalls related to validation metrics in image analysis. Focusing on biomedical image analysis but with the potential of transfer to other fields, the addressed pitfalls generalize across application domains and are categorized according to a newly created, domain-agnostic taxonomy. To facilitate comprehension, illustrations and specific examples accompany each pitfall. As a structured body of information accessible to researchers of all levels of expertise, this work enhances global comprehension of a key topic in image analysis validation.

cs.CV↗

Metrics reloaded: Recommendations for image analysis validation

Increasing evidence shows that flaws in machine learning (ML) algorithm validation are an underestimated global problem. Particularly in automatic biomedical image analysis, chosen performance metrics often do not reflect the domain interest, thus failing to adequately measure scientific progress and hindering translation of ML techniques into practice. To overcome this, our large international expert consortium created Metrics Reloaded, a comprehensive framework guiding researchers in the problem-aware selection of metrics. Following the convergence of ML methodology across application domains, Metrics Reloaded fosters the convergence of validation methodology. The framework was developed in a multi-stage Delphi process and is based on the novel concept of a problem fingerprint - a structured representation of the given problem that captures all aspects that are relevant for metric selection, from the domain interest to the properties of the target structure(s), data set and algorithm output. Based on the problem fingerprint, users are guided through the process of choosing and applying appropriate validation metrics while being made aware of potential pitfalls. Metrics Reloaded targets image analysis problems that can be interpreted as a classification task at image, object or pixel level, namely image-level classification, object detection, semantic segmentation, and instance segmentation tasks. To improve the user experience, we implemented the framework in the Metrics Reloaded online tool, which also provides a point of access to explore weaknesses, strengths and specific recommendations for the most common validation metrics. The broad applicability of our framework across domains is demonstrated by an instantiation for various biological and medical image analysis use cases.

cs.CV↗

Nodule detection and generation on chest X-rays: NODE21 Challenge

Pulmonary nodules may be an early manifestation of lung cancer, the leading cause of cancer-related deaths among both men and women. Numerous studies have established that deep learning methods can yield high-performance levels in the detection of lung nodules in chest X-rays. However, the lack of gold-standard public datasets slows down the progression of the research and prevents benchmarking of methods for this task. To address this, we organized a public research challenge, NODE21, aimed at the detection and generation of lung nodules in chest X-rays. While the detection track assesses state-of-the-art nodule detection systems, the generation track determines the utility of nodule generation algorithms to augment training data and hence improve the performance of the detection systems. This paper summarizes the results of the NODE21 challenge and performs extensive additional experiments to examine the impact of the synthetically generated nodule training images on the detection algorithm performance.

eess.IV↗

Common Limitations of Image Processing Metrics: A Picture Story

While the importance of automatic image analysis is continuously increasing, recent meta-research revealed major flaws with respect to algorithm validation. Performance metrics are particularly key for meaningful, objective, and transparent performance assessment and validation of the used automatic algorithms, but relatively little attention has been given to the practical pitfalls when using specific metrics for a given image analysis task. These are typically related to (1) the disregard of inherent metric properties, such as the behaviour in the presence of class imbalance or small target structures, (2) the disregard of inherent data set properties, such as the non-independence of the test cases, and (3) the disregard of the actual biomedical domain interest that the metrics should reflect. This living dynamically document has the purpose to illustrate important limitations of performance metrics commonly applied in the field of image analysis. In this context, it focuses on biomedical image analysis problems that can be phrased as image-level classification, semantic segmentation, instance segmentation, or object detection task. The current version is based on a Delphi process on metrics conducted by an international consortium of image analysis experts from more than 60 institutions worldwide.

eess.IV↗

Transfer learning from a sparsely annotated dataset of 3D medical images

Transfer learning leverages pre-trained model features from a large dataset to save time and resources when training new models for various tasks, potentially enhancing performance. Due to the lack of large datasets in the medical imaging domain, transfer learning from one medical imaging model to other medical imaging models has not been widely explored. This study explores the use of transfer learning to improve the performance of deep convolutional neural networks for organ segmentation in medical imaging. A base segmentation model (3D U-Net) was trained on a large and sparsely annotated dataset; its weights were used for transfer learning on four new down-stream segmentation tasks for which a fully annotated dataset was available. We analyzed the training set size's influence to simulate scarce data. The results showed that transfer learning from the base model was beneficial when small datasets were available, providing significant performance improvements; where fine-tuning the base model is more beneficial than updating all the network weights with vanilla transfer learning. Transfer learning with fine-tuning increased the performance by up to 0.129 (+28\%) Dice score than experiments trained from scratch, and on average 23 experiments increased the performance by 0.029 Dice score in the new segmentation tasks. The study also showed that cross-modality transfer learning using CT scans was beneficial. The findings of this study demonstrate the potential of transfer learning to improve the efficiency of annotation and increase the accessibility of accurate organ segmentation in medical imaging, ultimately leading to improved patient care. We made the network definition and weights publicly available to benefit other users and researchers.

eess.IV↗