Searcharxiv⌕ Search

arXiv subjects

Brendan Burkhart

Publications and source records attributed to Brendan Burkhart.

4 recordsLinked to original sources

ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery

Research on surgical autonomy needs open platforms that any laboratory can build, yet the most widely shared platform depends on donated clinical hardware, and open alternatives on industrial arms each lack part of the surgical chain. We present the Autonomous Robotic Translational System (ARTS), an open-source three-arm platform for autonomy research in minimally invasive surgery, built entirely from purchasable parts for about USD 137,000. Two UR5e arms hold wristed da Vinci X/Xi instruments, a UR5 arm holds a stereo endoscope with two FLIR cameras, the surgeon console provides haptic handles, footswitches and a stereo viewer, and a hardware stop independent of the software lets a supervisor freeze all three arms in place. The ROS 2 software pins every dependency, installs from the same scripts on bare metal or in containers, and records stereo images with hardware-measured timing. On the real arms, ARTS commands each arm at its controller's full rate (e.g., 500 Hz on the UR5e), the two cameras expose within 12 microseconds of each other, hand motion reaches the arm in 58 ms, and the endoscope image reaches the monitor in 68 ms. The ISO 9283 pose repeatability is 0.14-0.25 mm, comparable to a da Vinci Research Kit (dVRK) Classic arm on the same protocol, and an optical tracker measured a mean remote-center-of-motion error of 0.34-0.37 mm. Three expert and three novice operators performed the Fundamentals of Laparoscopic Surgery (FLS) peg transfer through a laparoscopic trainer box, and one of the experts sutured on a suture pad. The hardware designs, firmware and software are available at https://github.com/MRE-Lab-UMD/arts.

cs.RO↗

Dynamic Model Identification and Gravity Compensation for the dVRK-Si Patient Side Manipulator

The da Vinci Research Kit (dVRK) has been widely used for research in robot-assisted surgery over the past decade, and its latest generation, the dVRK-Si was made publicly available in 2025. This manuscript presents the first complete kinematic and dynamic modeling framework for the dVRK-Si Patient-Side Manipulator (PSM), whose redesigned mechanism differs substantially from that of the first-generation dVRK and therefore requires a new formulation to accurately capture gravitational effects and improve overall control performance. We first develop a modified DH kinematic model that represents the dVRK-Si PSM's redesigned mechanism. The equations of motion are then derived using the Euler-Lagrange formulation, and the inverse dynamics are expressed in a linear-in-parameters regressor form. The dynamic parameters are identified from data collected along a periodic excitation trajectory optimized for numerical conditioning and estimated by convex optimization subject to the physical feasibility constraints. The identified model is integrated into the dVRK control stack to enable real-time gravity compensation and computed-torque feedforward control. Experiments on a physical dVRK-Si demonstrate that the gravity compensation reduces steady-state joint errors by up to 84% and decreases end-effector tip drift during static holds from 4.2 mm to 0.7 mm. Computed-torque feedforward control further improves transient and trajectory-tracking accuracy. During sinusoidal trajectory tracking, computed-torque feedforward reduces position errors by 35\% versus gravity-only feedforward and by 40% versus PID-only. The proposed pipeline could support reliable control, high-fidelity simulation, and learning-based automation on the dVRK-Si.

cs.RO↗

PERSEUS: Perception with Semantic Endoscopic Understanding and SLAM

Purpose: Natural orifice surgeries minimize the need for incisions and reduce the recovery time compared to open surgery; however, they require a higher level of expertise due to visualization and orientation challenges. We propose a perception pipeline for these surgeries that allows semantic scene understanding. Methods: We bring learning-based segmentation, depth estimation, and 3D reconstruction modules together to create real-time segmented maps of the surgical scenes. Additionally, we use registration with robot poses to solve the scale ambiguity of mapping from monocular images, and allow the use of semantically informed real-time reconstructions in robotic surgeries. Results: We achieve sub-milimeter reconstruction accuracy based on average one-sided Chamfer distances, average pose registration RMSE of 0.9 mm, and an estimated scale within 2% of ground truth. Conclusion: We present a modular perception pipeline, integrating semantic segmentation with real-time monocular SLAM for natural orifice surgeries. This pipeline offers a promising solution for scene understanding that can facilitate automation or surgeon guidance.

cs.RO↗

A Supervised Autonomous Resection and Retraction Framework for Transurethral Enucleation of the Prostatic Median Lobe

Concentric tube robots (CTRs) offer dexterous motion at millimeter scales, enabling minimally invasive procedures through natural orifices. This work presents a coordinated model-based resection planner and learning-based retraction network that work together to enable semi-autonomous tissue resection using a dual-arm transurethral concentric tube robot (the Virtuoso). The resection planner operates directly on segmented CT volumes of prostate phantoms, automatically generating tool trajectories for a three-phase median lobe resection workflow: left/median trough resection, right/median trough resection, and median blunt dissection. The retraction network, PushCVAE, trained on surgeon demonstrations, generates retractions according to the procedural phase. The procedure is executed under Level-3 (supervised) autonomy on a prostate phantom composed of hydrogel materials that replicate the mechanical and cutting properties of tissue. As a feasibility study, we demonstrate that our combined autonomous system achieves a 97.1% resection of the targeted volume of the median lobe. Our study establishes a foundation for image-guided autonomy in transurethral robotic surgery and represents a first step toward fully automated minimally-invasive prostate enucleation.

cs.RO↗