SearcharxivSearch

arXiv subjects

Brett Levac

Publications and source records attributed to Brett Levac.

11 recordsLinked to original sources

Normalization-equivariant Diffusion Models: Learning Posterior Samplers From Noisy And Partial Measurements

Diffusion models (DMs) have rapidly emerged as a powerful framework for image generation and restoration. However, existing DMs are primarily trained in a supervised manner by using a large corpus of clean images. This reliance on clean data poses fundamental challenges in many real-world scenarios, where acquiring noise-free data is hard or infeasible, and only noisy and potentially incomplete measurements are available. While some methods can train DMs using noisy data, they are generally effective only when the amount of noise is very mild or when some additional noise-free data is available. In addition, existing methods for training DMs from incomplete measurements require access to multiple complementary acquisition processes, an assumption that poses a significant practical limitation. Here we introduce the first approach for learning DMs for image restoration using only noisy measurement data from a single operator. As a first key contribution, we show that DMs, and more broadly minimum mean squared error denoisers, exhibit a weak form of scale equivariance linking rescaling in signal amplitude to changes in noise intensity. We then leverage this theoretical insight to develop a denoising score-matching strategy that generalizes robustly to noise levels lower than those present in the training data, thereby enabling the learning of DMs from noisy measurements. To further address the challenges of incomplete and noisy data, we integrate our method with equivariant imaging, a complementary self-supervised learning framework that exploits the inherent invariants of imaging problems, to train DMs for image restoration from single-operator measurements that are both incomplete and noisy. We validate the effectiveness of our approach through extensive experiments on image denoising, demosaicing, and inpainting, along with comparisons with the state of the art.

eess.IV

DeepInverse: A Python package for solving imaging inverse problems with deep learning

DeepInverse is an open-source PyTorch-based library for solving imaging inverse problems. The library covers all crucial steps in image reconstruction from the efficient implementation of forward operators (e.g., optics, MRI, tomography), to the definition and resolution of variational problems and the design and training of advanced neural network architectures. In this paper, we describe the main functionality of the library and discuss the main design choices.

eess.IV

Diffusion Probabilistic Generative Models for Accelerated, in-NICU Permanent Magnet Neonatal MRI

Purpose: Magnetic Resonance Imaging (MRI) enables non-invasive assessment of brain abnormalities during early life development. Permanent magnet scanners operating in the neonatal intensive care unit (NICU) facilitate MRI of sick infants, but have long scan times due to lower signal-to-noise ratios (SNR) and limited receive coils. This work accelerates in-NICU MRI with diffusion probabilistic generative models by developing a training pipeline accounting for these challenges. Methods: We establish a novel training dataset of clinical, 1 Tesla neonatal MR images in collaboration with Aspect Imaging and Sha'are Zedek Medical Center. We propose a pipeline to handle the low quantity and SNR of our real-world dataset (1) modifying existing network architectures to support varying resolutions; (2) training a single model on all data with learned class embedding vectors; (3) applying self-supervised denoising before training; and (4) reconstructing by averaging posterior samples. Retrospective under-sampling experiments, accounting for signal decay, evaluated each item of our proposed methodology. A clinical reader study with practicing pediatric neuroradiologists evaluated our proposed images reconstructed from 1.5x under-sampled data. Results: Combining all data, denoising pre-training, and averaging posterior samples yields quantitative improvements in reconstruction. The generative model decouples the learned prior from the measurement model and functions at two acceleration rates without re-training. The reader study suggests that proposed images reconstructed from approximately 1.5x under-sampled data are adequate for clinical use. Conclusion: Diffusion probabilistic generative models applied with the proposed pipeline to handle challenging real-world datasets could reduce scan time of in-NICU neonatal MRI.

eess.IV

Double Blind Imaging with Generative Modeling

Blind inverse problems in imaging arise from uncertainties in the system used to collect (noisy) measurements of images. Recovering clean images from these measurements typically requires identifying the imaging system, either implicitly or explicitly. A common solution leverages generative models as priors for both the images and the imaging system parameters (e.g., a class of point spread functions). To learn these priors in a straightforward manner requires access to a dataset of clean images as well as samples of the imaging system. We propose an AmbientGAN-based generative technique to identify the distribution of parameters in unknown imaging systems, using only unpaired clean images and corrupted measurements. This learned distribution can then be used in model-based recovery algorithms to solve blind inverse problems such as blind deconvolution. We successfully demonstrate our technique for learning Gaussian blur and motion blur priors from noisy measurements and show their utility in solving blind deconvolution with diffusion posterior sampling.

eess.IV

A Generative Diffusion Model to Solve Inverse Problems for Robust in-NICU Neonatal MRI

We present the first acquisition-agnostic diffusion generative model for Magnetic Resonance Imaging (MRI) in the neonatal intensive care unit (NICU) to solve a range of inverse problems for shortening scan time and improving motion robustness. In-NICU MRI scanners leverage permanent magnets at lower field-strengths (i.e., below 1.5 Tesla) for non-invasive assessment of potential brain abnormalities during the critical phase of early live development, but suffer from long scan times and motion artifacts. In this setting, training data sizes are small and intrinsically suffer from low signal-to-noise ratio (SNR). This work trains a diffusion probabilistic generative model using such a real-world training dataset of clinical neonatal MRI by applying several novel signal processing and machine learning methods to handle the low SNR and low quantity of data. The model is then used as a statistical image prior to solve various inverse problems at inference time without requiring any retraining. Experiments demonstrate the generative model's utility for three real-world applications of neonatal MRI: accelerated reconstruction, motion correction, and super-resolution.

physics.med-ph

INFusion: Diffusion Regularized Implicit Neural Representations for 2D and 3D accelerated MRI reconstruction

Implicit Neural Representations (INRs) are a learning-based approach to accelerate Magnetic Resonance Imaging (MRI) acquisitions, particularly in scan-specific settings when only data from the under-sampled scan itself are available. Previous work demonstrates that INRs improve rapid MRI through inherent regularization imposed by neural network architectures. Typically parameterized by fully-connected neural networks, INRs support continuous image representations by taking a physical coordinate location as input and outputting the intensity at that coordinate. Previous work has applied unlearned regularization priors during INR training and have been limited to 2D or low-resolution 3D acquisitions. Meanwhile, diffusion based generative models have received recent attention as they learn powerful image priors decoupled from the measurement model. This work proposes INFusion, a technique that regularizes the optimization of INRs from under-sampled MR measurements with pre-trained diffusion models for improved image reconstruction. In addition, we propose a hybrid 3D approach with our diffusion regularization that enables INR application on large-scale 3D MR datasets. 2D experiments demonstrate improved INR training with our proposed diffusion regularization, and 3D experiments demonstrate feasibility of INR training with diffusion regularization on 3D matrix sizes of 256 by 256 by 80.

eess.IV

Ambient Diffusion Posterior Sampling: Solving Inverse Problems with Diffusion Models Trained on Corrupted Data

We provide a framework for solving inverse problems with diffusion models learned from linearly corrupted data. Firstly, we extend the Ambient Diffusion framework to enable training directly from measurements corrupted in the Fourier domain. Subsequently, we train diffusion models for MRI with access only to Fourier subsampled multi-coil measurements at acceleration factors R= 2,4,6,8. Secondly, we propose Ambient Diffusion Posterior Sampling (A-DPS), a reconstruction algorithm that leverages generative models pre-trained on one type of corruption (e.g. image inpainting) to perform posterior sampling on measurements from a different forward process (e.g. image blurring). For MRI reconstruction in high acceleration regimes, we observe that A-DPS models trained on subsampled data are better suited to solving inverse problems than models trained on fully sampled data. We also test the efficacy of A-DPS on natural image datasets (CelebA, FFHQ, and AFHQ) and show that A-DPS can sometimes outperform models trained on clean data for several image restoration tasks in both speed and performance.

cs.CV

Optimizing Sampling Patterns for Compressed Sensing MRI with Diffusion Generative Models

Magnetic resonance imaging (MRI) is a powerful medical imaging modality, but long acquisition times limit throughput, patient comfort, and clinical accessibility. Diffusion-based generative models serve as strong image priors for reducing scan-time with accelerated MRI reconstruction and offer robustness across variations in the acquisition model. However, most existing diffusion-based approaches do not exploit the unique ability in MRI to jointly design both the sampling pattern and the reconstruction method. While prior learning-based approaches have optimized sampling patterns for end-to-end unrolled networks, analogous methods for diffusion-based reconstruction have not been established due to the computational burden of posterior sampling. In this work, we propose a method to optimize k-space sampling patterns for accelerated multi-coil MRI reconstruction using diffusion models as priors. We introduce a training objective based on a single-step posterior mean estimate that avoids backpropagation through an expensive iterative reconstruction process. Then we present a greedy strategy for learning Cartesian sampling patterns that selects informative k-space locations using gradient information from a pre-trained diffusion model while enforcing spatial diversity among samples. Experimental results across multiple anatomies and acceleration factors demonstrate that diffusion models using the optimized sampling patterns achieve higher-quality reconstructions in comparison to using fixed and learned baseline patterns.

cs.LG

MRI Reconstruction with Side Information using Diffusion Models

Magnetic resonance imaging (MRI) exam protocols consist of multiple contrast-weighted images of the same anatomy to emphasize different tissue properties. Due to the long acquisition times required to collect fully sampled k-space measurements, it is common to only collect a fraction of k-space for each scan and subsequently solve independent inverse problems for each image contrast. Recently, there has been a push to further accelerate MRI exams using data-driven priors, and generative models in particular, to regularize the ill-posed inverse problem of image reconstruction. These methods have shown promising improvements over classical methods. However, many of the approaches neglect the additional information present in a clinical MRI exam like the multi-contrast nature of the data and treat each scan as an independent reconstruction. In this work we show that by learning a joint Bayesian prior over multi-contrast data with a score-based generative model we are able to leverage the underlying structure between random variables related to a given imaging problem. This leads to an improvement in image reconstruction fidelity over generative models that rely only on a marginal prior over the image contrast of interest.

eess.IV

Accelerated Motion Correction with Deep Generative Diffusion Models

Magnetic Resonance Imaging (MRI) is a powerful medical imaging modality, but unfortunately suffers from long scan times which, aside from increasing operational costs, can lead to image artifacts due to patient motion. Motion during the acquisition leads to inconsistencies in measured data that manifest as blurring and ghosting if unaccounted for in the image reconstruction process. Various deep learning based reconstruction techniques have been proposed which decrease scan time by reducing the number of measurements needed for a high fidelity reconstructed image. Additionally, deep learning has been used to correct motion using end-to-end techniques. This, however, increases susceptibility to distribution shifts at test time (sampling pattern, motion level). In this work we propose a framework for jointly reconstructing highly sub-sampled MRI data while estimating patient motion using diffusion based generative models. Our method does not make specific assumptions on the sampling trajectory or motion pattern at training time and thus can be flexibly applied to various types of measurement models and patient motion. We demonstrate our framework on retrospectively accelerated 2D brain MRI corrupted by rigid motion.

eess.IV

FSE Compensated Motion Correction for MRI Using Data Driven Methods

Magnetic Resonance Imaging (MRI) is a widely used medical imaging modality boasting great soft tissue contrast without ionizing radiation, but unfortunately suffers from long acquisition times. Long scan times can lead to motion artifacts, for example due to bulk patient motion such as head movement and periodic motion produced by the heart or lungs. Motion artifacts can degrade image quality and in some cases render the scans nondiagnostic. To combat this problem, prospective and retrospective motion correction techniques have been introduced. More recently, data driven methods using deep neural networks have been proposed. As a large number of publicly available MRI datasets are based on Fast Spin Echo (FSE) sequences, methods that use them for training should incorporate the correct FSE acquisition dynamics. Unfortunately, when simulating training data, many approaches fail to generate accurate motion-corrupt images by neglecting the effects of the temporal ordering of the k-space lines as well as neglecting the signal decay throughout the FSE echo train. In this work, we highlight this consequence and demonstrate a training method which correctly simulates the data acquisition process of FSE sequences with higher fidelity by including sample ordering and signal decay dynamics. Through numerical experiments, we show that accounting for the FSE acquisition leads to better motion correction performance during inference.

eess.SP