SearcharxivSearch

arXiv subjects

Brian Sands

Publications and source records attributed to Brian Sands.

9 recordsLinked to original sources

The Calibration System of the iLocater Spectrograph

iLocater is a new near-infrared, extreme precision radial velocity (EPRV) instrument delivered to the Large Binocular Telescope in the summer of 2026. The instrument utilizes single-mode fibers (SMFs) for light transmission, including its calibration systems. We present an overview of the iLocater calibration system, detailing the specific sources and the hardware required to inject calibration light into the SMFs. Furthermore, we discuss the hardware that efficiently switches between these sources and distributes the light to all necessary instrument locations, entirely eliminating the need for free-space propagation.

astro-ph.IM

Commissioning and on-sky performance verification of iLocater

iLocater is a high-resolution near-infrared extreme precision radial velocity (EPRV) spectrograph that was deployed to the Large Binocular Telescope (LBT) in June 2026. iLocater operates over $\lambda=966-1312$ nm with a median resolving power of $R=205,000$ as measured in the laboratory. We present the commissioning and initial on-sky verification program using solar and night-time observations at the LBT. First light was achieved on 27 June 2026, and nearly 150 on-sky spectra have now been recorded. Observations include single stars ranging in spectral type from B5 to M6. iLocater uses the LBT AO system, and we have demonstrated its ability to obtain spatially resolved spectra of close ($\theta < 1''$) binary stars.

astro-ph.IM

Laboratory characterization of iLocater

iLocater is a diffraction-limited, fiber-fed spectrograph designed for the Large Binocular Telescope (LBT), which targets high-precision radial velocity measurements in the near-infrared. Prior to deployment, comprehensive laboratory characterization was essential to validate instrument performance and inform alignment strategies. This paper presents results from four key areas of lab characterization: (1) adjustment and optimization of detector orientation to optimize spectrum alignment with the detector pixel grid across the focal plane; (2) the design and installation of a LED illumination source to enable high-fidelity flat-fields; (3) a model-based focusing methodology using OpticStudio image simulations to optimize the optical alignment of the spectrograph; and (4) assessment of instrument mechanical and optical stability under laboratory conditions. Together, these efforts established baseline performance metrics and demonstrated instrument readiness for delivery and on-sky commissioning.

astro-ph.IM

Phase Retrieval using Nonlinear Curvature Sensing within Convergent Beams

Path-length diversity methods may be used for adaptive optics (AO) systems to retrieve phase and amplitude information by measuring intensity across multiple planes. Observations that rely on free-space propagation, such as the nonlinear curvature wavefront sensor (WFS), have been shown to offer excellent sensitivity and robustness to scintillation. However, the default design results in a large opto-mechanical footprint due to unavoidable geometric-optics and wave-optics effects. Measurements recorded in a convergent beam would improve instrument compactness, while concentrating light into smaller detector regions of interest, improving signal-to-noise ratio and possibly wavefront reconstruction speed. In this paper, we study path-length diversity wavefront sensing using four planes of contemporaneous intensity measurements made in a convergent beam. We develop a physical optics propagation model and validate the model by performing wavefront reconstructions in both simulations and lab experiments. The manuscripts core contribution is a practical, intensity-domain, Fourier-transform-based recipe to use a conventional multi-plane Gerchberg-Saxton (or comparable) reconstruction pipeline with convergent-beam measurements, enabling a compact optical layout. We find that this approach offers practical benefits over an equivalent free-space wavefront sensor, in particular reducing size, weight, complexity and cost.

physics.optics

Jitter Sensing and Control for Multi-Plane Phase Retrieval

The family of multi-plane phase retrieval sensors, such as the curvature and nonlinear curvature wavefront sensors (WFS), contain tip/tilt information embedded in their signals. We have built a nonlinear curvature WFS to study different wavefront reconstruction methods and test the ability to extract tip/tilt information. Using reliable and fast centroiding algorithms, combined with knowledge of the measured $z$-distance to each measurement plane, we demonstrate that image jitter may be sensed and compensated for using a fast steering mirror and the WFS in closed loop. This approach obviates the need for peripheral components such as quad-cells or access to a separate scientific imaging channel. Our laboratory experiments validate tip/tilt estimation and correction using nlCWFS data, achieving tip/tilt accuracy of +/-0.1, lambda/D for an unaberrated beam and better than ~+/-0.5, lambda/D in the presence of aberrations, consistent with prior numerical simulations. We further demonstrate a closed-loop tip/tilt control implementation and show a qualitative improvement in the stability and overall quality of multi-plane phase retrieval reconstructions.

astro-ph.IM

Little iLocater: paving the way for iLocater

Diffraction-limited radial velocity instruments offer a pathway towards improved precision and stability, and the exploration of new parameter spaces at high spatial and spectral resolution. However, achieving the necessary performance requires careful instrument design and considerable on-sky testing. We describe the design and construction of ``Little iLocater'' (Lili), a compact spectrograph that has been used to validate the performance of the front-end fibre-injection system of the iLocater spectrograph. We present the design, assembly, and performance using on-sky data obtained at the Large Binocular Telescope (LBT), including extraction of spectra from standard stars, testing of the atmospheric dispersion corrector to elevations of 40 degrees, and spatially resolved spectra from close companion systems. These results show the front-end fibre-injection system is performing as expected and is indicative of iLocater's capabilities once installed at the LBT.

astro-ph.IM

The iLocater cryostat and thermal control system: enabling extremely precise radial velocity measurements for diffraction-limited spectrographs

Extremely precise radial velocity (EPRV) measurements are critical for characterizing nearby terrestrial worlds. EPRV instrument precisions of $σ_{\mathrm{RV}} = 1-10\,\mathrm{cm/s}$ are required to study Earth-analog systems, imposing stringent, sub-mK, thermo-mechanical stability requirements on Doppler spectrograph designs. iLocater is a new, high-resolution ($R=190,500$ median) near infrared (NIR) EPRV spectrograph under construction for the dual 8.4 m diameter Large Binocular Telescope (LBT). The instrument is one of the first to operate in the diffraction-limited regime enabled by the use of adaptive optics and single-mode fibers. This facilitates affordable optomechanical fabrication of the spectrograph using intrinsically stable materials. We present the final design and performance of the iLocater cryostat and thermal control system which houses the instrument spectrograph. The spectrograph is situated inside an actively temperature-controlled radiation shield mounted inside a multi-layer-insulation (MLI) lined vacuum chamber. The radiation shield provides sub-mK thermal stability, building on the existing heritage of the Habitable-zone Planet Finder (HPF) and NEID instruments. The instrument operating temperature ($T=80-100\,\mathrm{K}$) is driven by the requirement to minimize detector background and instantaneous coefficient of thermal expansion (CTE) of the materials used for spectrograph fabrication. This combination allows for a reduced thermomechanical impact on measurement precision, improving the scientific capabilities of the instrument.

astro-ph.IM

On-sky results for the novel integrated micro-lens ring tip-tilt sensor

We present the first on-sky results of the micro-lens ring tip-tilt (MLR-TT) sensor. This sensor utilizes a 3D printed micro-lens ring feeding six multi-mode fibers to sense misaligned light, allowing centroid reconstruction. A tip-tilt mirror allows the beam to be corrected, increasing the amount of light coupled into a centrally positioned single-mode (science) fiber. The sensor was tested with the iLocater acquisition camera at the Large Binocular Telescope in November 2019. The limit on the maximum achieved root mean square reconstruction accuracy was found to be 0.19 $λ$/D in both tip and tilt, of which approximately 50% of the power originates at frequencies below 10 Hz. We show the reconstruction accuracy is highly dependent on the estimated Strehl ratio and simulations support the assumption that residual adaptive optics aberrations are the main limit to the reconstruction accuracy. We conclude that this sensor is ideally suited to remove post-adaptive optics non-common path tip tilt residuals. We discuss the next steps for the concept development, including optimizations of the lens and fiber, tuning of the correction algorithm and selection of optimal science cases.

astro-ph.IM

Final Design and On-Sky Testing of the iLocater SX Acquisition Camera: Broadband Single-Mode Fiber Coupling

Enabling efficient injection of light into single-mode fibers (SMFs) is a key requirement in realizing diffraction-limited astronomical spectroscopy on ground-based telescopes. SMF-fed spectrographs, facilitated by the use of adaptive optics (AO), offer distinct advantages over comparable seeing-limited designs, including higher spectral resolution within a compact and stable instrument volume, and a telescope independent spectrograph design. iLocater is an extremely precise radial velocity (EPRV) spectrograph being built for the Large Binocular Telescope (LBT). We have designed and built the front-end fiber injection system, or acquisition camera, for the SX (left) primary mirror of the LBT. The instrument was installed in 2019 and underwent on-sky commissioning and performance assessment. In this paper, we present the instrument requirements, acquisition camera design, as well as results from first-light measurements. Broadband single-mode fiber coupling in excess of 35% (absolute) in the near-infrared (0.97-1.31μm) was achieved across a range of target magnitudes, spectral types, and observing conditions. Successful demonstration of on-sky performance represents both a major milestone in the development of iLocater and in making efficient ground-based SMF-fed astronomical instruments a reality.

astro-ph.IM