Searcharxiv⌕ Search

arXiv subjects

Brodi D. Elwood

Publications and source records attributed to Brodi D. Elwood.

4 recordsLinked to original sources

BICEP/Keck XXI: Constraints on Early-Universe Parity Violation from Multipole-Dependent Birefringence

We present the first constraints on multipole-dependent cosmic birefringence using CMB polarization data from the BK18 dataset, which combines observations from BICEP2, Keck Array, and BICEP3 at frequencies of 95, 150, and 220 GHz. Photon coupling to an axion-like field leads to the rotation of CMB polarization, inducing non-zero EB cross-correlations. We show that a multipole-dependent rotation beta(l) imprints a distinct signature in the polarization spectra that can be constrained. Specifically, we consider an Early Dark Energy (EDE) scenario in which a pseudoscalar field couples to photons through a Chern-Simons interaction, generating a polarization rotation with multipole dependence. We introduce a phenomenological beta(l) as a step function, obtaining constraints on the step function size consistent with zero, with uncertainties less than 0.15 degrees (68% CL). In addition, using multi-frequency EE, BB, and EB cross-spectra, along with robust BICEP/Keck foreground treatment and likelihood framework, we derive constraints on the axion-photon coupling amplitude g for several choices of EDE parameters. For the baseline best-fit value f_{EDE} = 0.087 from the Planck 2018 analysis, we obtain g = 0.11 +/- 0.37 (68% CL), consistent with previous limits.

astro-ph.CO↗

Fabry-Pérot open resonant cavities for measuring the dielectric parameters of mm-wave optical materials

As millimeter-wave cosmology experiments refine their optical chains, precisely characterizing their optical materials under cryogenic conditions becomes increasingly important. For instance, as the aperture sizes and bandwidths of millimeter-wave receivers increase, the design of antireflection coatings becomes progressively more constrained by an accurate measure of material optical properties in order to achieve forecasted performance. Likewise, understanding dielectric and scattering losses is relevant to photon noise modeling in presently-deploying receivers such as BICEP Array and especially to future experiments such as CMB-S4. Additionally, the design of refractive elements such as lenses necessitates an accurate measure of the refractive index. High quality factor Fabry-Pérot open resonant cavities provide an elegant means for measuring these optical properties. Employing a hemispherical resonator that is compatible with a quick-turnaround 4 Kelvin cryostat, we can measure the dielectric and scattering losses of low-loss materials at both ambient and cryogenic temperatures. We review the design, characterization, and metrological applications of quasioptical cavities commissioned for measuring the dielectric materials in the BICEP3 (95 GHz) and BICEP Array mid-frequency (150 GHz) optics. We also discuss the efforts to improve the finesse of said cavities, for better resolution of degenerate higher order modes, which can provide stronger constraints on cavity parameters and sample material thickness.

physics.optics↗

Calibration Measurements of the BICEP3 and BICEP Array CMB Polarimeters from 2017 to 2024

The BICEP3 and BICEP Array polarimeters are small-aperture refracting telescopes located at the South Pole designed to measure primordial gravitational wave signatures in the Cosmic Microwave Background (CMB) polarization, predicted by inflation. Constraining the inflationary signal requires not only excellent sensitivity, but also careful control of instrumental systematics. Both instruments use antenna-coupled orthogonally polarized detector pairs, and the polarized sky signal is reconstructed by taking the difference in each detector pair. As a result, the differential response between detectors within a pair becomes an important systematic effect we must control. Additionally, mapping the intensity and polarization response in regions away from the main beam can inform how sidelobe levels affect CMB measurements. Extensive calibration measurements are taken in situ every austral summer for control of instrumental systematics and instrument characterisation. In this work, we detail the set of beam calibration measurements that we conduct on the BICEP receivers, from deep measurements of main beam response to polarized beam response and sidelobe mapping. We discuss the impact of these measurements for instrumental systematics studies and design choices for future CMB receivers.

astro-ph.CO↗

Searching for Axion Dark Matter with Birefringent Cavities

Axion-like particles are a broad class of dark matter candidates which are expected to behave as a coherent, classical field with a weak coupling to photons. Research into the detectability of these particles with laser interferometers has recently revealed a number of promising experimental designs. Inspired by these ideas, we propose the Axion Detection with Birefringent Cavities (ADBC) experiment, a new axion interferometry concept using a cavity that exhibits birefringence between its two, linearly polarized laser eigenmodes. This experimental concept overcomes several limitations of the designs currently in the literature, and can be practically realized in the form of a simple bowtie cavity with tunable mirror angles. Our design thereby increases the sensitivity to the axion-photon coupling over a wide range of axion masses.

hep-ph↗