Searcharxiv⌕ Search

arXiv subjects

César Blanch

Publications and source records attributed to César Blanch.

3 recordsLinked to original sources

TARDIS Lab: infrastructure for characterization and assembly of highly granular silicon calorimeter modules for LUXE and future Higgs Factories

The TARDIS Lab has been established at IFIC (CSIC-UV) to develop infrastructure and expertise in high-granularity silicon calorimetry. The laboratory provides an ISO7 clean-room environment and dedicated instrumentation for silicon sensor characterization and ultra-thin calorimeter module assembly. It supports developments of silicon-based high-granularity calorimetry concepts pursued within CERN DRD Calo (DRD6) and the FCAL Collaboration. These developments serve not only as technological prototypes of the electromagnetic calorimeters and luminometers at future Higgs-factory proposals (FCC-ee, Linear Collider Facility at CERN, International Linear Collider, etc.) but are also essential for the strong-field QED program of the LUXE experiment. We describe the laboratory infrastructure, assembly workflows and DESY test-beam validation of fully assembled calorimeter modules. The assembled ECALp modules have an average thickness of approximately 760~$μ$m, while laboratory tests of 4352 channels identified connectivity problems in only 0.5\% of them. For the two SiWECAL modules assembled in 2025, connectivity problems were observed at the level of approximately $10^{-3}$ of the instrumented pads, with no mechanical failures or sensor delamination after transport and beam operation. We also present ongoing infrastructure upgrades and production milestones for 2026-2027.

physics.ins-det↗

Dielectric Assist Accelerating Structures for Compact Linear Accelerators of Low Energy Particles in Hadrontherapy Treatments

Dielectric Assist Accelerating (DAA) structures based on ultralow-loss ceramic are being studied as an alternative to conventional disk-loaded copper cavities. This accelerating structure consists of dielectric disks with irises arranged periodically in metallic structures working under the TM$_{02}$-$π$ mode. In this paper, the numerical design of an S-band DAA structure for low beta particles, such as protons or carbon ions used for Hadrontherapy treatments, is shown. Four dielectric materials with different permittivity and loss tangent are studied as well as different particle velocities. Through optimization, a design that concentrates most of the RF power in the vacuum space near the beam axis is obtained, leading to a significant reduction of power loss on the metallic walls. This allows to fabricate cavities with an extremely high quality factor, over 100 000, and shunt impedance over 300 M$Ω$/m at room temperature. During the numerical study, the design optimization has been improved by adjusting some of the cell parameters in order to both increase the shunt impedance and reduce the peak electric field in certain locations of the cavity, which can lead to instabilities in its normal functioning.

physics.acc-ph↗

Non-resonant ultra-fast multipactor regime in dielectric-assist accelerating structures

The objective of this work is the evaluation of the risk of suffering a multipactor discharge in an S-band dielectric-assist accelerating (DAA) structure for a compact low-energy linear particle accelerator dedicated to hadrontherapy treatments. A DAA structure consists of ultra-low loss dielectric ciylinders and disks with irises which are periodically arranged in a metallic enclosure, with the advantage of having an extremely high quality factor and very high shunt impedance at room temperature, and it is therefore proposed as a potential alternative to conventional disk-loaded copper structures. However, it has been observed that these structures suffer from multipactor discharges. In fact, multipactor is one of the main problems of these devices, as it limits the maximum accelerating gradient. Because of this, the analysis of multipactor risk in the early design steps of DAA cavities is crucial to ensure the correct performance of the device after fabrication. In this paper, we present a comprehensive and detailed study of multipactor in our DAA design through numerical simulations performed with an in-house developed code based on the Monte-Carlo method. The phenomenology of the multipactor (resonant electron trajectories, electron flight time between impacts, etc.) is described in detail for different values of the accelerating gradient. It has been found that in these structures an ultra-fast non-resonant multipactor appears, which is different from the types of multipactor theoretically studied in the scientific literature. In addition, the effect of several low electron emission coatings on the multipactor threshold is investigated. Furthermore, a novel design based on the modification of the DAA cell geometry for multipactor mitigation is introduced, which shows a significant increase in the accelerating gradient handling capabilities of our prototype.

physics.acc-ph↗