SearcharxivSearch

arXiv subjects

C. Adolphsen

Publications and source records attributed to C. Adolphsen.

18 recordsLinked to original sources

European Strategy for Particle Physics -- Accelerator R&D Roadmap

The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.

physics.acc-ph

LCLS-II-HE verification cryomodule high gradient performance and quench behavior

An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.

physics.acc-ph

Untrapped HOM Radiation Absorption in the LCLS-II Cryomodules

The superconducting cavities in the continuous wave (CW) linacs of LCLS-II are designed to operate at 2 K, where cooling costs are very expensive. One source of heat is presented by the higher order mode (HOM) power deposited by the beam. Due to the very short bunch length--especially in L3 the final linac--the LCLS-II beam spectrum extends into the terahertz range. Ceramic absorbers, at 70 K and located between cryomodules, are meant to absorb much of this power. In this report we perform two kinds of calculations to estimate the effectiveness of the absorbers and the amount of beam power that needs to be removed at 2 K.

physics.acc-ph

A Large Hadron Electron Collider at CERN

This document provides a brief overview of the recently published report on the design of the Large Hadron Electron Collider (LHeC), which comprises its physics programme, accelerator physics, technology and main detector concepts. The LHeC exploits and develops challenging, though principally existing, accelerator and detector technologies. This summary is complemented by brief illustrations of some of the highlights of the physics programme, which relies on a vastly extended kinematic range, luminosity and unprecedented precision in deep inelastic scattering. Illustrations are provided regarding high precision QCD, new physics (Higgs, SUSY) and electron-ion physics. The LHeC is designed to run synchronously with the LHC in the twenties and to achieve an integrated luminosity of O(100) fb$^{-1}$. It will become the cleanest high resolution microscope of mankind and will substantially extend as well as complement the investigation of the physics of the TeV energy scale, which has been enabled by the LHC.

hep-ex

On the Relation of the LHeC and the LHC

The present note relies on the recently published conceptual design report of the LHeC and extends the first contribution to the European strategy debate in emphasising the role of the LHeC to complement and complete the high luminosity LHC programme. The brief discussion therefore focuses on the importance of high precision PDF and $α_s$ determinations for the physics beyond the Standard Model (GUTs, SUSY, Higgs). Emphasis is also given to the importance of high parton density phenomena in nuclei and their relevance to the heavy ion physics programme at the LHC.

hep-ex

A Large Hadron Electron Collider at CERN: Report on the Physics and Design Concepts for Machine and Detector

The physics programme and the design are described of a new collider for particle and nuclear physics, the Large Hadron Electron Collider (LHeC), in which a newly built electron beam of 60 GeV, up to possibly 140 GeV, energy collides with the intense hadron beams of the LHC. Compared to HERA, the kinematic range covered is extended by a factor of twenty in the negative four-momentum squared, $Q^2$, and in the inverse Bjorken $x$, while with the design luminosity of $10^{33}$ cm$^{-2}$s$^{-1}$ the LHeC is projected to exceed the integrated HERA luminosity by two orders of magnitude. The physics programme is devoted to an exploration of the energy frontier, complementing the LHC and its discovery potential for physics beyond the Standard Model with high precision deep inelastic scattering measurements. These are designed to investigate a variety of fundamental questions in strong and electroweak interactions. The physics programme also includes electron-deuteron and electron-ion scattering in a $(Q^2, 1/x)$ range extended by four orders of magnitude as compared to previous lepton-nucleus DIS experiments for novel investigations of neutron's and nuclear structure, the initial conditions of Quark-Gluon Plasma formation and further quantum chromodynamic phenomena. The LHeC may be realised either as a ring-ring or as a linac-ring collider. Optics and beam dynamics studies are presented for both versions, along with technical design considerations on the interaction region, magnets and further components, together with a design study for a high acceptance detector. Civil engineering and installation studies are presented for the accelerator and the detector. The LHeC can be built within a decade and thus be operated while the LHC runs in its high-luminosity phase. It thus represents a major opportunity for progress in particle physics exploiting the investment made in the LHC.

physics.acc-ph

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider and other proposed high energy e+ e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 1e-4. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006--2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5e-4 was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

physics.acc-ph

Crab cavities for linear colliders

Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.

physics.acc-ph

Cavity BPM System Tests for the ILC Spectrometer

The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a $1\m$ long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a $30\m$ long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.

physics.ins-det

Energy dispersion compensation and beam loading in X-band linacs for the JLC/NLC

The shape of an RF pulse is distorted upon propagating through an X-band accelerator structure due to dispersive effects. This distortion together with beam loading introduce energy spread between 192 bunches. In order to minimize this energy spread we modify the input RF pulse shape. The pulse propagation, energy gain, and beam loading are modelled with a mode-matching computer code and a circuit model. A 2D model and a circuit model of a complete 60 cm structure, consisting of 55 cells and input and output couplers is analyzed. This structure operates with a 5pi/6 phase advance per cell. Dispersive effects for this structure are more significant than for previously studied 2pi/3 phase advance accelerating structures. Experimental results are compared with the theoretical model and excellent agreement is obtained for the propagation of an RF pulse through the structure.

physics.acc-ph

Room temperature accelerator structures for linear colliders

Early tests of short low group velocity and standing wave structures indicated the viability of operating X-band linacs with accelerating gradients in excess of 100 MeV/m. Conventional scaling of traveling wave traveling wave linacs with frequency scales the cell dimensions with l. Because Q scales as l1/2, the length of the structures scale not linearly but as l3/2 in order to preserve the attenuation through each structure. For NLC we chose not to follow this scaling from the SLAC S-band linac to its fourth harmonic at X-band. We wanted to increase the length of the structures to reduce the number of couplers and waveguide drives which can be a significant part of the cost of a microwave linac. Furthermore, scaling the iris size of the disk-loaded structures gave unacceptably high short range dipole wakefields. Consequently, we chose to go up a factor of about 5 in average group velocity and length of the structures, which increases the power fed to each structure by the same factor and decreases the short range dipole wakes by a similar factor. Unfortunately, these longer (1.8 m) structures have not performed nearly as well in high gradient tests as the short structures. We believe we have at least a partial understanding of the reason and will discuss it below. We are now studying two types of short structures with large apertures with moderately good efficiency including: 1) traveling wave structures with the group velocity lowered by going to large phase advance per period with bulges on the iris, 2) pi mode standing wave structures

physics.acc-ph

Processing Studies of X-Band Accelerator Structures at the NLCTA

RF processing studies of 1.8-m X-band (11.4 GHz) traveling wave structures at the Next Linear Collider Test Accelerator (NLCTA) have revealed breakdown-related damage at gradients lower than expected from earlier tests with standing wave and shorter, lower group velocity traveling wave structures. To understand this difference, a series of structures with different group velocities and lengths are being processed. In parallel, efforts are being made to improve processing procedures and to reduce structure contaminants and absorbed gases. This paper presents results from these studies.

physics.acc-ph

Design, fabrication and measurement of the first rounded damped detuned accelerator structure (RDDS1)

As a joint effort in the JLC/NLC research program, we have developed a new type of damped detuned accelerator structure with optimized round-shaped cavities (RDDS). This paper discusses some important R&D aspects of the first structure in this series (RDDS1). The design aspects covered are the cell design with sub-MHz precision, HOM detuning, coupling and damping technique and wakefield simulation. The fabrication issues covered are ultra-precision cell machining with micron accuracy, assembly and diffusion bonding technologies to satisfactorily meet bookshelf, straightness and cell rotational alignment requirements. The measurements described are the RF properties of single cavities and complete accelerator section, as well as wakefields from the ASSET tests at SLAC. Finally, future improvements are also discussed.

physics.acc-ph

Higher Dipole Bands in the NLC Accelerating Structure

We show that scattering matrix calculations for dipole modes between 23-43 GHz for the 206 cell detuned structure (DS) are consistent with finite element calculations and results of the uncoupled model. In particular, the rms sum wake for these bands is comparable to that of the first dipole band. We also show that for RDDS1 uncoupled wakefield calculations for higher bands are consistent with measurements. In particular, a clear 26 GHz signal in the short range wake is found in both results.

physics.acc-ph

RF Processing of X-band Accelerator Structures at the NLCTA

During the initial phase of operation, the linacs of the Next Linear Collider (NLC) will contain roughly 5000 X-Band accelerator structures that will accelerate beams of electrons and positrons to 250 GeV. These structures will nominally operate at an unloaded gradient of 72 MV/m. As part of the NLC R&D program, several prototype structures have been built and operated at the Next Linear Collider Test Accelerator (NLCTA) at SLAC. Here, the effect of high gradient operation on the structure performance has been studied. Significant progress was made during the past year after the NLCTA power sources were upgraded to reliably produce the required NLC power levels and beyond. This paper describes the structures, the processing methodology and the observed effects of high gradient operation.

physics.acc-ph

RF Control System for the NLC Linacs

The proposed Next Linear Collider contains a large number of linac RF systems with new requirements for wideband klystron modulation and accurate RF vector detection. The system will be capable of automatically phasing each klystron and compensating for beam loading effects. Accelerator structure alignment is determined by detection of the beam induced dipole modes with a receiver similar to that used for measuring the accelerator RF and is incorporated into the RF system topology. This paper describes the proposed system design, signal processing techniques and includes preliminary test results.

physics.acc-ph

The Proposed NLC Linac LLRF System

The proposed Next Linear Collider (NLC) contains linac systems operating at L,S,C, and X band. This paper describes a wideband modular low-level RF (LLRF) system applicable for all NLC pulsed RF systems. High speed digital IF techniques are used for both arbitrary klystron drive modulation and accurate RF vector detection. Measurement of relative beam to RF phase, beam loading compensation, and structure dipole modes for automated alignment are all handled by the system. Modern signal processing techniques are also described.

physics.acc-ph

Beam Profile Monitors in the Nlcta

The transverse current profile in the Next Linear Collider Test Accelerator (NLCTA) electron beam can be monitored at several locations along the beam line by means of profile monitors. These consist of insertable phosphor screens, light collection and transport systems, CID cameras, a frame-grabber, and PC and VAX based image analysis software. In addition to their usefulness in tuning and steering the accelerator, the profile monitors are utilized for emittance measurement. A description of these systems and their performance is presented.

physics.acc-ph