SearcharxivSearch

arXiv subjects

C. Amoros

Publications and source records attributed to C. Amoros.

9 recordsLinked to original sources

ECLAIRs: the SVOM high-energy transient trigger camera

The core instrument of the SVOM Gamma-ray burst mission launched in June 2024 is the 4-150 keV 2-D coded mask camera ECLAIRs responsible for the autonomous trigger and localization of transient events within its field of view. The flight model of ECLAIRs has been built by several French labs (IRAP, CEA, APC) under the supervision of the French Space Agency (CNES), while APC, LUPM and IAP built a suite of data reduction and analysis software. This paper outlines the main science goals of ECLAIRs and describes the different instrument sub-systems and their main characteristics. The paper then discusses the instrument configuration and operation as well as the main in-flight measured performances. Finally, the paper summarizes the science performance of ECLAIRs up to March 31, 2025.

astro-ph.HE

SVOM/ECLAIRs detection plane: main features and performance

The detection plane of the high-energy transient camera ECLAIRs onboard SVOM is made of 200 XRDPIX detection modules, each consisting of a matrix of $8\times 4$ Schottky-type CdTe detectors hybridized with the low-noise and low-consumption ASIC IDeF-X. The 6400 detectors are operated at -20{\deg}C and reverse biased at -300 V, reaching a low energy threshold of 4 keV. The 20 us time resolution readout electronics works in photon counting mode classifying detected events as single or multiple events and measuring the deposited energy in real time. In this paper, we present the detection plane sub-systems and their main features. We also discuss its overall performances as measured both on ground and in-flight, showing compliance with the ECLAIRs science requirements.

astro-ph.IM

Designing large pixelated CdTe detection planes for hard X-ray transients detection

We discuss the need for very large detection planes for the detection of hard X-ray transients in the multi-messenger era that started with the quasi-simultaneous detection of GRB~170817A by \textit{Fermi}/GBM and \textit{INTEGRAL}/SPI on one hand and the gravitational waves event GW 170817, detected by the LVC collaboration, on the other hand. Then, we present a brief survey of current and future instruments and their expected sensitivity, pointing the fact that the gain in the number of GRBs is achieved by future projects thanks to their larger field of view rather than to their larger effective area. Based on our experience with \textit{SVOM}/ECLAIRs, we then address various problems associated with the realization of very large detection planes (\mbox{$\ge 1 \mathrm m^{2}$}), and we demonstrate that CdTe detectors are well suited for this task. We conclude with a discussion of some key parameters that must be taken into account in the realization of instruments based on these detectors. We hope that this paper will motivate the elaboration of detailed proposals of large area wide-field hard X-ray monitors that will be crucially needed in the next decade.

astro-ph.IM

The Large Observatory For x-ray Timing

The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.

astro-ph.IM

The X-/Gamma-ray camera ECLAIRs for the Gammay-ray burst mission SVOM

We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$ detection plane coupled to a data processing unit, so-called UGTS, which is in charge of locating GRBs in near real time thanks to image and rate triggers. We present the instrument science requirements and how the design of ECLAIRs has been optimized to increase its sensitivity to high-redshift GRBs and low-luminosity GRBs in the local Universe, by having a low-energy threshold of 4 keV. The total spectral coverage ranges from 4 to 150 keV. ECLAIRs is expected to detect $\sim 200$ GRBs of all types during the nominal 3 year mission lifetime. To reach a 4 keV low-energy threshold, the ECLAIRs detection plane is paved with 6400 $4\times 4~\mathrm{mm}^2$ and 1 mm-thick Schottky CdTe detectors. The detectors are grouped by 32, in 8x4 matrices read by a low-noise ASIC, forming elementary modules called XRDPIX. In this paper, we also present our current efforts to investigate the performance of these modules with their front-end electronics when illuminated by charged particles and/or photons using radioactive sources. All measurements are made in different instrument configurations in vacuum and with a nominal in-flight detector temperature of $-20^\circ$C. This work will enable us to choose the in-flight configuration that will make the best compromise between the science performance and the in-flight operability of ECLAIRs. We will show some highlights of this work.

physics.ins-det

The Hot and Energetic Universe: The Wide Field Imager (WFI) for Athena+

The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon counting. The instrument is designed to make optimal use of the grasp (collecting area times solid angle product) provided by the optical design of the Athena+ mirror system (Willingale et al. 2013), by combining a sensitive approx. 40' diameter field of view (baseline; 50' goal) DEPFET detector with a pixel size properly sampling the angular resolution of 5 arc sec on-axis (half energy width).This synthesis makes the WFI a very powerful survey instrument, significantly surpassing currently existing capabilities (Nandra et al. 2013; Aird et al. 2013). In addition, the WFI will provide unprecedented simultaneous high-time resolution and high count rate capabilities for the observation of bright sources with low pile-up and high efficiency. In this paper, we summarize the instrument design, the status of the technology development, and the baseline performance.

astro-ph.IM

LOFT: the Large Observatory For X-ray Timing

The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neutron stars, as well as the physical state of ultra-dense matter. These primary science goals will be addressed by a payload composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1 degree field of view) experiment operating in the energy range 2-50 keV, with a 10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM will operate in the same energy range as the LAD, enabling simultaneous monitoring of a few-steradian wide field of view, with an angular resolution of <5 arcmin. The LAD and WFM experiments will allow us to investigate variability from submillisecond QPO's to year-long transient outbursts. In this paper we report the current status of the project.

astro-ph.IM

The Wide-Field X and Gamma-Ray Telescope ECLAIRs aboard the Gamma-Ray Burst Multi-Wavelength Space Mission SVOM

The X and Gamma-ray telescope ECLAIRs is foreseen to be launched on a low Earth orbit (h=630 km, i=30 degrees) aboard the SVOM satellite (Space-based multi-band astronomical Variable Objects Monitor), a French-Chinese mission with Italian contribution. Observations are expected to start in 2013. It has been designed to detect and localize Gamma-Ray Bursts (GRBs) or persistent sources of the sky, thanks to its wide field of view (about 2 sr) and its remarkable sensitivity in the 4-250 keV energy range, with enhanced imaging sensitivity in the 4-70 keV energy band. These characteristics are well suited to detect highly redshifted GRBs, and consequently to provide fast and accurate triggers to other onboard or ground-based instruments able to follow-up the detected events in a very short time from the optical wavelength bands up to the few MeV Gamma-Ray domain.

astro-ph

Development of a modular CdTe detector plane for gamma-ray burst detection below 100 keV

We report on the development of an innovative CdTe detector plane (DPIX) optimized for the detection and localization of gamma-ray bursts in the X-ray band (below 100 keV). DPIX is part of an R&D program funded by the French Space Agency (CNES). DPIX builds upon the heritage of the ISGRI instrument, currently operating with great success on the ESA INTEGRAL mission. DPIX is an assembly of 200 elementary modules (XRDPIX) equipped with 32 CdTe Schottky detectors (4x4 mm2, 1 mm thickness) produced by ACRORAD Co. LTD. in Japan. These detectors offer good energy response up to 100 keV. Each XRDPIX is readout by the very low noise front-end electronics chip IDeF-X, currently under development at CEA/DSM/DAPNIA. In this paper, we describe the design of XRDPIX, the main features of the IDeF-X chip, and will present preliminary results of the reading out of one CdTe Schottky detector by the IDeF-X V1.0 chip. A low-energy threshold around 2.7 keV has been measured. This is to be compared with the 12-15 keV threshold of the ISGRI-INTEGRAL and BAT-SWIFT instruments, which both use similar detector material.

astro-ph