SearcharxivSearch

arXiv subjects

C. Benson

Publications and source records attributed to C. Benson.

3 recordsLinked to original sources

Data reduction pipeline for the SuMAC millimeter-wave spectrometer at the LMT

We present the data reduction and analysis pipeline for the SuperSpec-MUSCAT Collaboration (SuMAC) along with several key science data products. In Summer 2025, SuperSpec on-chip spectrometers operating from $190-300$ GHz at $R\sim200$ were deployed in the MUSCAT cryostat at the Large Millimeter Telescope, obtaining several days of on-sky data. Analysis of these data has been used to characterize noise performance and study spectra of various astrophysical sources, establishing the viability of deploying SuperSpec detectors in future instruments. These proceedings discuss the modular data reduction pipeline which uses timestreams of the kinetic inductance detectors (KIDs) and auxiliary instrument data to generate a variety of data products. We present an on-sky calibration method for converting the KID fractional frequency shift to on-sky brightness temperature. The mapmaking module generates 3D data cubes of extended sources, while the spectrum module produces a millimeter-wave spectrum of an object. The observations all incorporate measurements of the atmosphere to model and correct for absorption. We also discuss data processing choices including detector weighting, despiking, and notch filtering. Finally, we present preliminary data products including detection of carbon monoxide in NGC 253 and spectral maps of the central region of the Orion KL nebula.

astro-ph.IM

Correcting the extended-source calibration for the Herschel-SPIRE Fourier-Transform Spectrometer

We describe an update to the Herschel-SPIRE Fourier-Transform Spectrometer (FTS) calibration for extended sources, which incorporates a correction for the frequency-dependent far-field feedhorn efficiency, $\eta_\mathrm{FF}$. This significant correction affects all FTS extended-source calibrated spectra in sparse or mapping mode, regardless of the spectral resolution. Line fluxes and continuum levels are underestimated by factors of 1.3-2 in the Spectrometer Long-Wavelength band (SLW, 447-1018 GHz; 671-294 $\mu$m) and 1.4-1.5 in the Spectrometer Short-Wavelength band (SSW, 944-1568 GHz; 318-191 $\mu$m). The correction was implemented in the FTS pipeline version 14.1 and has also been described in the SPIRE Handbook since Feb 2017. Studies based on extended-source calibrated spectra produced prior to this pipeline version should be critically reconsidered using the current products available in the Herschel Science Archive. Once the extended-source calibrated spectra are corrected for $\eta_\mathrm{FF}$, the synthetic photometry and the broadband intensities from SPIRE photometer maps agree within 2-4% -- similar levels to the comparison of point-source calibrated spectra and photometry from point-source calibrated maps. The two calibration schemes for the FTS are now self-consistent: the conversion between the corrected extended-source and point-source calibrated spectra can be achieved with the beam solid angle and a gain correction that accounts for the diffraction loss.

astro-ph.IM

Measurement of the vector analyzing power in elastic electron-proton scattering as a probe of double photon exchange amplitudes

We report the first measurement of the vector analyzing power in inclusive transversely polarized elastic electron-proton scattering at Q^2 = 0.1 (GeV/c)^2 and large scattering angles. This quantity should vanish in the single virtual photon exchange, plane wave impulse approximation for this reaction, and can therefore provide information on double photon exchange amplitudes for electromagnetic interactions with hadronic systems. We find a non-zero value of A=-15.4+/-5.4 ppm. No calculations of this observable for nuclei other than spin 0 have been carried out in these kinematics, and the calculation using the spin orbit interaction from a charged point nucleus of spin 0 cannot describe these data.

nucl-ex