Searcharxiv⌕ Search

arXiv subjects

C. Bucci

Publications and source records attributed to C. Bucci.

At least 73 records · Page 4Linked to original sources

Double beta decay results from the CUPID-0 experiment

A convincing observation of neutrino-less double beta decay (0$ν$DBD) relies on the possibility of operating high energy-resolution detectors in background-free conditions. Scintillating cryogenic calorimeters are one of the most promising tools to fulfill the requirements for a next-generation experiment. Several steps have been taken to demonstrate the maturity of this technique, starting from the successful experience of CUPID-0. The CUPID-0 experiment demonstrated the complete rejection of the dominant alpha background measuring the lowest counting rate in the region of interest for this technique. Furthermore, the most stringent limit on the $^{82}$Se 0$ν$DBD was established running 26 ZnSe crystals during two years of continuous detector operation. In this contribution we present the final results of CUPID-0 Phase I including a detailed model of the background, the measurement of the $^{82}$Se 2$ν$DBD half-life and the evidence that this nuclear transition is single state dominated.

nucl-ex↗

Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment

The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.

physics.ins-det↗

A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.

physics.ins-det↗

Search for Neutrino-less Double Beta Decay of $^{64}$Zn and $^{70}$Zn with CUPID-0

CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the underground Laboratori Nazionali del Gran Sasso. In this work, we analyzed a ZnSe exposure of 11.34 kg$\times$yr to search for the neutrino-less double beta decay of $^{70}$Zn and for the neutrino-less positron-emitting electron capture of $^{64}$Zn. We found no evidence for these decays and set 90$\%$ credible interval limits of ${\rm T}_{1/2}^{0νββ}(^{70}{\rm Zn}) > 1.6 \times 10^{21}$ yr and ${\rm T}_{1/2}^{0νEC β+}(^{64}{\rm Zn}) > 1.2 \times 10^{22}$ yr, surpassing by almost two orders of magnitude the previous experimental results

nucl-ex↗

Description of CRESST-III Data

In CRESST-III, 10 cryogenic detector modules optimized for low energy thresholds were operated for almost two years (May 2016 - February 2018). Together with this document we are publishing data from the best performing detector module which has a nuclear recoil threshold of 30.1eV. With this data-set we were able to set limits on the cross-section for spin-dependent and spin-independent elastic scattering of dark matter particles off nuclei at dark matter masses down to 160MeV/c$^2$. We publish the energies of all events after data selection as well as of all events within the acceptance region for dark-matter searches. In this document we describe how to use these data sets.

astro-ph.CO↗

Improved Limit on Neutrinoless Double-Beta Decay in $^{130}$Te with CUORE

We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a total exposure of 372.5 kg$\cdot$yr, we attain a median exclusion sensitivity of $1.7\cdot10^{25}$ yr. We find no evidence for $0νββ$ decay and set a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the $^{130}$Te half-life for this process. In the hypothesis that $0νββ$ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

nucl-ex↗

Evidence of Single State Dominance in the Two-Neutrino Double-$β$ Decay of Se-82 with CUPID-0

We report on the measurement of the two-neutrino double-$β$ decay of $^{82}$Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0~experiment. With an exposure of 9.95 kg$\times$yr of Zn$^{82}$Se, we determine the two-neutrino double-$β$ decay half-life of $^{82}$Se with an unprecedented precision level, $T_{1/2}^{2ν} = [8.60 \pm 0.03 \textrm{(stat.)}~^{+0.17}_{-0.10} \textrm{(syst.)}] \times 10^{19}~\textrm{yr}$. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5 $σ$.

nucl-ex↗

First search for Lorentz violation in double beta decay with scintillating calorimeters

We present the search for Lorentz violation in the double beta decay of ^{82}Se~with CUPID-0, using an exposure of 9.95 kg x y. We found no evidence for the searched signal and set a limit on the isotropic components of the Lorentz violating coefficient of $\mathring{a}_{\text{of}}^{(3)} < 4.1\cdot10^{-6}$ GeV (90\% Credible Interval). This results is obtained with a Bayesian analysis of the experimental data and fully includes the systematic uncertainties of the model. This is the first limit on $\mathring{a}_{\text{of}}^{(3)}$ obtained with a scintillating bolometer, showing the potentiality of this technique.

nucl-ex↗

First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li

In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.

astro-ph.IM↗

Geant4-based electromagnetic background model for the CRESST dark matter experiment

The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to $(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.

astro-ph.IM↗

Background Model of the CUPID-0 Experiment

CUPID-0 is the first large mass array of enriched Zn$^{82}$Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of 9.95 kg yr. Thanks to the excellent rejection of $α$ particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of $^{82}$Se neutrinoless double beta decay. In this work we develop a model to reconstruct the CUPID-0 background over the whole energy range of experimental data. We identify the background sources exploiting their distinctive signatures and we assess their extremely low contribution (down to $\sim10^{-4}$ counts/(keV kg yr)) in the region of interest for $^{82}$Se neutrinoless double beta decay search. This result represents a crucial step towards the comprehension of the background in experiments based on scintillating calorimeters and in next generation projects such as CUPID.

nucl-ex↗

The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures

The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.

physics.ins-det↗

Final result of CUPID-0 phase-I in the search for the $^{82}$Se Neutrinoless Double Beta Decay

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0$ν$DBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a $^{82}$Se exposure of 5.29 kg$\times$yr. In this paper we present the phase-I results in the search for 0$ν$DBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: $(3.5^{+1.0}_{-0.9})\times10^{-3}$ counts/(keV kg yr). Monitoring 3.88$\times$10$^{25}$ $^{82}$Se nuclei$\times$yr we reach a 90% credible interval median sensitivity of $\rm{T}^{0ν}_{1/2}>5.0\times10^{24} \rm{yr}$ and set the most stringent limit on the half-life of $^{82}$Se 0$ν$DBD : $\rm{T}^{0ν}_{1/2}>3.5\times10^{24} \rm{yr}$ (90% credible interval), corresponding to m$_{ββ} <$ (311-638) meV depending on the nuclear matrix element calculations.

nucl-ex↗

Results of CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently in data taking, searching for the neutrinoless double beta decay of 130 Te. CUORE is operational since the spring of 2017. The initial science run already allowed to provide the most stringent limit on the neutrinoless double beta decay half-life of 130Te, and to perform the most precise measurement of the two-neutrino double beta decay half-life. Up to date, we have more than doubled the collected exposure. In this talk, we presenteded the most recent results and discuss the present status of the CUORE experiment.

nucl-ex↗

First results from the CRESST-III low-mass dark matter program

The CRESST experiment is a direct dark matter search which aims to measure interactions of potential dark matter particles in an earth-bound detector. With the current stage, CRESST-III, we focus on a low energy threshold for increased sensitivity towards light dark matter particles. In this manuscript we describe the analysis of one detector operated in the first run of CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV. This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously emitted scintillation light, which is absorbed in a separate silicon-on-sapphire light absorber, are measured with highly sensitive transition edge sensors operated at ~15mK. The unique combination of these sensors with the light element oxygen present in our target yields sensitivity to dark matter particle masses as low as 160MeV/c$^2$.

astro-ph.CO↗

Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.

nucl-ex↗

Search of the neutrino-less double beta decay of $^{82}$Se into the excited states of $^{82}$Kr with CUPID-0

The CUPID0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95$\%$ enriched in $^{82}$Se and 2 natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of $^{82}$Se into the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr with an exposure of 5.74 kg$\cdot$yr (2.24$\times$10$^{25}$ emitters$\cdot$yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{0_1^+}$)$<$8.55$\times$10$^{-24}$ yr$^{-1}$, $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{2_1^+}$)$<6.25 \times10^{-24}$ yr$^{-1}$, $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{2_2^+}$)$<$8.25$\times$10$^{-24}$ yr$^{-1}$ (90$\%$ credible interval

nucl-ex↗

Limits on Dark Matter Effective Field Theory Parameters with CRESST-II

CRESST is a direct dark matter search experiment, aiming for an observation of nuclear recoils induced by the interaction of dark matter particles with cryogenic scintillating calcium tungstate crystals. Instead of confining ourselves to standard spin-independent and spin-dependent searches, we re-analyze data from CRESST-II using a more general effective field theory (EFT) framework. On many of the EFT coupling constants, improved exclusion limits in the low-mass region (< 3-4 GeV) are presented.

hep-ph↗