Performance of a CRESST-II Detector Module with True $4π$-veto

Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this detector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the framework of the CRESST-II experiment, we developed and successfully tested a novel detector design addressing both challenges. Using a large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber, the signal height recorded in the light channel is improved by a factor 2.5 compared to conventional CRESTT-II detector modules. In combination with a large carrier crystal, a true $4π$ veto system is established which allows to tag external background sources.

astro-ph.IM↗

Dark-Photon Search using Data from CRESST-II Phase 2

Identifying the nature and origin of dark matter is one of the major challenges for modern astro and particle physics. Direct dark-matter searches aim at an observation of dark-matter particles interacting within detectors. The focus of several such searches is on interactions with nuclei as provided e.g. by Weakly Interacting Massive Particles. However, there is a variety of dark-matter candidates favoring interactions with electrons rather than with nuclei. One example are dark photons, i.e., long-lived vector particles with a kinetic mixing to standard-model photons. In this work we present constraints on this kinetic mixing based on data from CRESST-II Phase 2 corresponding to an exposure before cuts of 52\,kg-days. These constraints improve the existing ones for dark-photon masses between 0.3 and 0.7\,keV/c$^2$.

hep-ex↗

Measurement of the Two-Neutrino Double Beta Decay Half-life of $^{130}$Te with the CUORE-0 Experiment

We report on the measurement of the two-neutrino double beta decay half-life of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of TeO$_2$, the half-life is determined to be $T_{1/2}^{2ν}$ = [8.2 $\pm$ 0.2 (stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the $^{130}$Te neutrinoless double beta decay region of interest.

nucl-ex↗

In-situ study of light production and transport in phonon/light detector modules for dark matter search

The CRESST experiment (Cryogenic Rare Event Search with Superconducting Thermometers) searches for dark matter via the phonon and light signals of elastic scattering processes in scintillating crystals. The discrimination between a possible dark matter signal and background is based on the light yield. We present a new method for evaluating the two characteristics of a phonon/light detector module that determine how much of the deposited energy is converted to scintillation light and how efficiently a module detects the produced light. In contrast to former approaches with dedicated setups, we developed a method which allows us to use data taken with the cryogenic setup, during a dark matter search phase. In this way, we accounted for the entire process that occurs in a detector module, and obtained information on the light emission of the crystal as well as information on the performance of the module (light transport and detection). We found that with the detectors operated in CRESST-II phase 1, about 20% of the produced scintillation light is detected. A part of the light is likely absorbed by creating meta-stable excitations in the scintillating crystals. The light not detected is not absorbed entirely, as an additional light detector can help to increase the fraction of detected light.

astro-ph.IM↗

The CUORE and CUORE-0 experiments at LNGS

The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the largest 130Te bolometric setup ever operated. CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from 2013 to 2015. The final CUORE-0 analysis on 0ν\b{eta}\b{eta} and the corresponding detector performance are presented. The present status of the CUORE experiment, now in its final construction and commissioning phase, are discussed. The results from assembly of the detector and the commissioning of the cryostat are reported.

physics.ins-det↗

New Limits on Double Electron Capture of $^{40}$Ca and $^{180}$W

We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these values improve the currently best limits by a factor of $\sim$1.4-30.

nucl-ex↗

Limits on momentum-dependent asymmetric dark matter with CRESST-II

The usual assumption in direct dark matter searches is to only consider the spin-dependent or spin-independent scattering of dark matter particles. However, especially in models with light dark matter particles $\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the momentum transfer $q^2$ can become dominant. One such model based on asymmetric dark matter has been invoked to overcome discrepancies in helioseismology and an indication was found for a particle with preferred mass of 3 $\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data from the CRESST-II experiment, which uses cryogenic detectors based on $\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter particles, are used to constrain these momentum-dependent models. The low energy threshold of 307 eV for nuclear recoils of the detector used, allows us to rule out the proposed best fit value above.

astro-ph.CO↗

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

physics.ins-det↗

Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.

nucl-ex↗

The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors

The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest bolometric mass ever operated. The experiment will work at a temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free system based on pulse tubes and a custom high power dilution refrigerator, designed to match these specifications. The cryostat has been commissioned in 2014 at the Gran Sasso National Laboratories and reached a record temperature of 6 mK on a cubic meter scale. In this paper, we present results of CUORE commissioning runs. Details on the thermal characteristics and cryogenic performances of the system will be also given.

physics.ins-det↗

Results on light dark matter particles with a low-threshold CRESST-II detector

The CRESST-II experiment uses cryogenic detectors to search for nuclear recoil events induced by the elastic scattering of dark matter particles in CaWO$_4$ crystals. Given the low energy threshold of our detectors in combination with light target nuclei, low mass dark matter particles can be probed with high sensitivity. In this letter we present the results from data of a single detector module corresponding to 52 kg live days. A blind analysis is carried out. With an energy threshold for nuclear recoils of 307 eV we substantially enhance the sensitivity for light dark matter. Thereby, we extend the reach of direct dark matter experiments to the sub-region and demonstrate that the energy threshold is the key parameter in the search for low mass dark matter particles.

astro-ph.CO↗

Beta/gamma and alpha backgrounds in CRESST-II Phase 2

The experiment CRESST-II aims at the detection of dark matter with scintillating CaWO$_4$ crystals operated as cryogenic detectors. Recent results on spin-independent WIMP-nucleon scattering from the CRESST-II Phase 2 allowed to probe a new region of parameter space for WIMP masses below 3 GeV/c$^2$. This sensitivity was achieved after background levels were reduced significantly. We present extensive background studies of a CaWO$_4$ crystal, called TUM40, grown at the Technische Universität München. The average beta/gamma rate of 3.51/[kg keV day] (1-40 keV) and the total intrinsic alpha activity from natural decay chains of $3.08\pm0.04$ mBq/kg are the lowest reported for CaWO$_4$ detectors. Contributions from cosmogenic activation, surface-alpha decays, external radiation and intrinsic alpha/beta emitters are investigated in detail. A Monte-Carlo based background decomposition allows to identify the origin of the majority of beta/gamma events in the energy region relevant for dark matter search.

physics.ins-det↗

Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures

Scintillating CaWO$_4$ single crystals are a promising multi-element target for rare-event searches and are currently used in the direct Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an active background discrimination and the identification of a possible signal induced by weakly interacting massive particles (WIMPs). We present the first precise measurements of the QFs of O, Ca and W at mK temperatures by irradiating a cryogenic detector with a fast neutron beam. A clear energy dependence of the QF of O and, less pronounced, of Ca was observed for the first time. Furthermore, in CRESST neutron-calibration data a variation of the QFs among different CaWO$_4$ single crystals was found. For typical CRESST detectors the QFs in the region-of-interest (10-40$\,$keV) are $QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and $QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed using these fundamentally new results on light quenching in CaWO$_4$ having moderate influence on the WIMP analysis. Their relevance for future CRESST runs and for the clarification of previously published results of direct Dark Matter experiments is emphasized.

astro-ph.IM↗

A detector module with highly efficient surface-alpha event rejection operated in CRESST-II Phase 2

The cryogenic dark matter experiment CRESST-II aims at the direct detection of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals. We present a new, highly improved, detector design installed in the current run of CRESST-II Phase 2 with an efficient active rejection of surface-alpha backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target crystal, a detector housing with fully-scintillating inner surface could be realized. The presented detector (TUM40) provides an excellent threshold of ${\sim}\,0.60\,$keV and a resolution of $σ\,{\approx}\,0.090$ keV (at 2.60$\,$keV). With significantly reduced background levels, TUM40 sets stringent limits on the spin-independent WIMP-nucleon scattering cross section and probes a new region of parameter space for WIMP masses below 3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the surface-alpha event rejection in detail.

physics.ins-det↗

Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0

We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.

nucl-ex↗

The CRESST Dark Matter Search - Status and Perspectives

In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unprecedented background level for CaWO$_4$ target crystals render TUM40 the detector with the best overall performance of CRESST-II phase 2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate light dark matter particles (<3GeV/c$^2$), previously not accessible for other direct detection experiments.

physics.ins-det↗

The CUORE and CUORE-0 Experiments at Gran Sasso

The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

physics.ins-det↗

CALDER - Neutrinoless double-beta decay identification in TeO$_2$ bolometers with kinetic inductance detectors

Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO$_2$ bolometers being commissioned at Laboratori Nazionali del Gran Sasso in Italy, features an expected sensitivity of 50-130 meV at 90% C.L, that can be improved by removing the background from $α$ radioactivity. This is possible if, in coincidence with the heat release in a bolometer, the Cherenkov light emitted by the $β$ signal is detected. The amount of light detected is so far limited to only 100 eV, requiring low-noise cryogenic light detectors. The CALDER project (Cryogenic wide-Area Light Detectors with Excellent Resolution) aims at developing a small prototype experiment consisting of TeO$_2$ bolometers coupled to new light detectors based on kinetic inductance detectors. The R&D is focused on the light detectors that could be implemented in a next-generation neutrinoless double-beta decay experiment.

physics.ins-det↗