SearcharxivSearch

arXiv subjects

C. Capelli

Publications and source records attributed to C. Capelli.

At least 19 recordsLinked to original sources

First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale

We report on the first measurement of low-energy solar neutrinos through elastic neutrino-electron scattering in a dark matter experiment, establishing the lowest energy threshold for any neutrino detection to date. The measurement utilizes data from the first two science runs of XENONnT, corresponding to an exposure of 2.46 t $\cdot$ y, and covers electron recoil energies between 1 keV and 140 keV, providing sensitivity to solar neutrinos with energies down to 17 keV. We reject the background-only hypothesis with a statistical significance of $5.0\sigma$ and measure a solar $pp$ neutrino flux of $(10.2 \pm 2.0) \times 10^{10}$ cm$^{-2}$ s$^{-1}$. The result is larger, but statistically consistent with the previous measurement by Borexino at $1.9\sigma$. Together with recent observations of coherent elastic neutrino-nucleus scattering of $^8$B solar neutrinos in XENONnT and other liquid-xenon time projection chambers, these results demonstrate the growing potential of liquid xenon detectors for neutrino physics down to the keV-scale and represent an important milestone towards a next-generation multipurpose observatory.

hep-ex

Search for Magnetic and Spin-Independent Inelastic Dark Matter with XENONnT

We present a search for Magnetic and Spin-Independent inelastic Dark Matter using 2.1 tonne-years of data from the XENONnT experiment. We consider both single- and double-site event topologies, targeting the unique signature of an initial nuclear recoil followed by a delayed de-excitation photon. To suppress backgrounds, we introduce novel directional and kinematic selections based on the inferred speed and direction of the excited dark matter particle between the scatter and decay sites. We find that the collected data are consistent with background expectations, and report 90% C.L. upper limits for both models across the GeV/c2-TeV/c2 mass range.

hep-ex

Direct Measurement of the $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ Decay Branching Ratios with the XENONnT Experiment

We present precision measurements of $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ decay branching ratios using $^{220}\mathrm{Rn}$ and $^{222}\mathrm{Rn}$ calibration data from the XENONnT detector, a dual-phase liquid xenon time projection chamber. Characterizing these isotopes is critical, as they lead to significant low-energy backgrounds in rare-event searches. We report ground-state branching ratios of $(14.75 \pm 0.20(\mathrm{stat}) ^{+0.14}_{-0.40}(\mathrm{sys}))\%$ for $^{212}\mathrm{Pb}$ and $(9.8 \pm 0.3(\mathrm{stat}) ^{+0.8}_{-0.2}(\mathrm{sys}))\%$ for $^{214}\mathrm{Pb}$, providing the most precise direct measurements of these transitions to date. These results contribute to enhancing background modeling for dark matter and neutrino experiments, improving sensitivity to solar neutrinos and physics beyond the Standard Model.

nucl-ex

Probing the Solar $^8$B Neutrino Fog with XENONnT

We report a 3.3 $\sigma$ measurement of coherent elastic neutrino-nucleus scattering from solar $^8$B neutrinos using a 6.77 t$\times$yr exposure from the XENONnT experiment, inferring a solar $^8$B neutrino flux of $(5_{-2}^{+3})\times 10^6\,\mathrm{cm}^{-2}\mathrm{s}^{-1}$, consistent with previous measurements. In the presence of the $^8$B "neutrino fog", we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV/$c^2$ spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at $\sim$ 0.02 GeV/$c$ momentum transfer and constrain physics beyond the Standard Model.

hep-ex

Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network

Dual-phase time projection chamber (TPC) that employs a multi-ton-scale liquid xenon (LXe) target mass is a pioneering detector technology to search for dark matter. Beyond its advantage in dark matter direct detection efforts, the natural xenon target allows it to search for the neutrinoless double-beta decay ($0\nu\beta\beta$) process, which would violate lepton number conservation and indicate that neutrinos are Majorana particles. However, such $0\nu\beta\beta$ searches have been limited by gamma-ray backgrounds originating from the detector materials. In this work, we designed an augmented convolutional neural network (A-CNN) model to extract additional event-topology information from detector data. Using simulation and calibration data from XENONnT, a leading LXe TPC experiment, our model achieved over 60% background rejection while maintaining 90% signal acceptance. This rejection power improves XENONnT's projected sensitivity of the $^{136}$Xe $0\nu\beta\beta$ search by about 40%. The implementation of A-CNN in the data analysis of future liquid xenon observatories, such as XLZD, will further enhance their sensitivities for $0\nu\beta\beta$ with $^{136}$Xe.

physics.ins-det

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by $\sim$1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of $\sim$100 $\mu$s, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1--5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

physics.ins-det

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}\nu\text{NS}$) becomes an irreducible background.

hep-ex

Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data

We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level.

hep-ex

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0\nu\beta\beta$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0\nu\beta\beta$ decay.

nucl-ex

Spectral Measurement of the $^{214}$Bi beta-decay to the $^{214}$Po Ground State with XENONnT

We report the measurement of the $^{214}$Bi beta-decay spectrum to the ground state of $^{214}$Po using the XENONnT detector. This decay is classified as first-forbidden non-unique, for which theoretical predictions require detailed nuclear structure modeling. A dedicated identification algorithm isolates a high-purity sample of ground-state beta-decays, explicitly excluding events with associated gamma-rays emission. By comparing the measured spectrum, which covers energies up to 3.27 MeV, with several nuclear models, we find that the prediction based on the conserved vector current (CVC) hypothesis provides the best description of the data. Using this dataset, we additionally derive charge and light yield curves for electronic recoils, extending detector response modeling up to the MeV scale.

nucl-ex

Cryogenic light detectors with thermal signal amplification for $0\nu\beta\beta$ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li$_{2}$$^{100}$MoO$_4$ crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of $O$(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

physics.ins-det

Challenging Spontaneous Quantum Collapse with XENONnT

We report on the search for X-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the X-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Di\'osi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. The original values proposed for the strength and the correlation length of the continuous spontaneous localization model are excluded experimentally for the first time.

hep-ex

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

hep-ex

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0\nu\beta\beta$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0\nu\beta\beta$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0\nu\beta\beta$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

physics.ins-det

Sensitivity of the CUPID experiment to $0\nu\beta\beta$ decay of $^{100}$Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo using Li$_2$MoO$_4$ scintillating crystals. It will operate 1596 crystals at $\sim$10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for $\alpha$ rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu\beta\beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \mathrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta\beta} < \ 9.6$ -- $28 \ \mathrm{meV}$. The Frequentist discovery sensitivity (3$\sigma$) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \mathrm{yr}$, corresponding to $\hat{m}_{\beta\beta}= \ 12$ -- $36 \ \mathrm{meV}$.

nucl-ex

Half-life and precision shape measurement of 2{\nu}{\beta}{\beta} decay of $^{130}$Te

We present a new measurement of the 2nbb half-life of 130Te (T1/2) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining T1/2 = (9.32 +0.05 -0.04 (stat.) +0.07 -0.07 (syst.)) x10^20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2nbb formalism to 130Te. Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0nbb searches.

nucl-ex

Innovating Bolometers' Mounting: A Gravity-Based Approach

Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of bolometers and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li$_2$MoO$_4$ crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than $\pm$0.5 mK at 10 mK, (ii) a good energy resolution of Li$_2$MoO$_4$ bolometers, (6.6 $\pm$ 2.2) keV FWHM at 2615 keV, and (iii) a Li$_2$MoO$_4$ light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

physics.ins-det

CUPID, the CUORE Upgrade with Particle IDentification

CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0\nu\beta\beta$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{\beta\beta}$) sensitivity of 9--15 meV, and a $3\sigma$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{\beta\beta}$ range of 12--21 meV.

physics.ins-det