SearcharxivSearch

arXiv subjects

C. Chiu

Publications and source records attributed to C. Chiu.

3 recordsLinked to original sources

Cross sections of $\eta$ mesons in $p$$+$$p$ collisions at forward rapidity at $\sqrt{s}=500$ GeV and central rapidity at $\sqrt{s}=510$ GeV

We present the first measurements of the forward and midrapidity $\eta$-meson cross sections from $p$$+$$p$ collisions at $\sqrt{s}=500$ and $510$~GeV, respectively. We also report the midrapidity $\eta/\pi^0$ ratio at 510 GeV. The forward cross section is measured differentially in $\eta$-meson transverse momentum ($p_T$) from 1.0 to 6.5~GeV/$c$ for pseudorapidity $3.0<|\eta|<3.8$. The midrapidity cross section is measured from 3.5 to 44 GeV/$c$ for pseudorapidity $|\eta|<0.35$. Both cross sections serve as critical inputs to an updated global analysis of the $\eta$-meson fragmentation functions.

hep-ex

Two-Stage nnU-Net for Automatic Multi-class Bi-Atrial Segmentation from LGE-MRIs

Late gadolinium enhancement magnetic resonance imaging (LGE-MRI) is used to visualise atrial fibrosis and scars, providing important information for personalised atrial fibrillation (AF) treatments. Since manual analysis and delineations of these images can be both labour-intensive and subject to variability, we develop an automatic pipeline to perform segmentation of the left atrial (LA) cavity, the right atrial (RA) cavity, and the wall of both atria on LGE-MRI. Our method is based on a two-stage nnU-Net architecture, combining 2D and 3D convolutional networks, and incorporates adaptive histogram equalisation to improve tissue contrast in the input images and morphological operations on the output segmentation maps. We achieve Dice similarity coefficients of 0.92 +/- 0.03, 0.93 +/- 0.03, 0.71 +/- 0.05 and 95% Hausdorff distances of (3.89 +/- 6.67) mm, (4.42 +/- 1.66) mm and (3.94 +/- 1.83) mm for LA, RA, and wall, respectively. The accurate delineation of the LA, RA and the myocardial wall is the first step in analysing atrial structure in cardiovascular patients, especially those with AF. This can allow clinicians to provide adequate and personalised treatment plans in a timely manner.

eess.IV

Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UVT) acrylic matrix is very similar to that of a coating using a polystyrene (PS) matrix. We obtain a factor of three higher light yield than has been previously reported from lightguides. This paper provides information on the response of the lightguides so that these can be modeled in simulations for future LArTPCs. This paper also identifies areas of R&D for potential improvements in the lightguide response

physics.ins-det