SearcharxivSearch

arXiv subjects

C. Colandrea

Publications and source records attributed to C. Colandrea.

8 recordsLinked to original sources

Infrared Thermography in the Tokamak \`a Configuration Variable

In the Tokamak \`a Configuration Variable (TCV), infrared thermography (IR) is currently composed of the horizontal, vertical, and tangential infrared systems (HIR, VIR, TIR), which all use Equus 81k M cameras. The IR diagnostics obtain the surface temperature of TCV's graphite tiles for post-discharge analysis. Target heat flux profiles are inferred from the tile temperature with the THEODOR (Thermal Energy Onto Divertor) code. Fast transient analysis is possible in reduced frame mode, with acquisition frequencies above 10kHz. The main views are the lower inner wall for HIR, the floor for VIR, and the lower outer wall for TIR. The HIR camera can also be moved to view the midplane inner wall, while TIR can be moved to see the midplane inner wall and the upper outer wall, mainly to measure synchrotron radiation and heat deposition due to runaway electrons. Recent developments in TCV's IR systems include (i) tile diffusivity and conductivity measurements to assure the precision of heat flux estimates; (ii) the addition of one new VIR heated valley tile and two rooftop TIR tiles, for measurements of fast heat flux transients; (iii) the implementation of long-pass wavelength filter of 4095 nm, to diminish the measurement of plasma parasitic infrared light, mainly from deuterium 5-4 emission at 4051 nm. Despite these developments, the main sources of uncertainty for IR in TCV are still parasitic infrared light and the determination of the surface layer heat transmission factor, both of which mainly affect the VIR system.

physics.plasm-ph

Investigating the influence of divertor baffles on nitrogen-seeded detachment in TCV with SOLPS-ITER simulations and TCV experiments

Plasma edge simulations with the SOLPS-ITER code are performed to study the influence of divertor baffles on nitrogen-seeded detachment in TCV single-null, L-mode discharges. Scans of nitrogen seeding rate are conducted in both baffled and unbaffled TCV divertors, where the nitrogen seeding with baffles is found to yield lower target temperatures and heat fluxes than with baffles-only and with seeding-only. The cumulative effects of baffles and seeding on target parameters are explained by the two-point model. The divertor neutral density and neutral compression increase with baffles, due to lower divertor to main chamber neutral conductance, as explained by a schematic neutral transport model with baffles. The nitrogen retention, defined as the ratio of average nitrogen nuclei density in divertor and main chamber, increases with the seeding rate if baffled, and remains constant if unbaffled. At the same outboard mid-plane separatrix plasma density, the nitrogen retention with baffles is lower than the unbaffled retention at low seeding levels and is higher at high seeding levels, which is explained by the changes of nitrogen ion and neutral transport with baffles and seeding. The baffled carbon retention is higher than the unbaffled retention due to lower divertor to main chamber carbon neutral conductance. Baffles increase the divertor radiation. The predicted trends of target parameters, the distribution of neutrals and radiations are well supported by TCV experiments, though discrepancies in the absolute values remain. The simulations yield an overall colder and denser divertor, consistent with previous SOLPS-ITER simulations of Ohmically heated L-modes in TCV. The successful comparison of simulation and experiment, together with the understanding gained from the neutral transport model, increases the confidence in the SOLPS simulations for the next TCV divertor upgrade.

physics.plasm-ph

Validation of SOLPS-ITER Simulations against the TCV-X21 Reference Case

This paper presents a quantitative validation of SOLPS-ITER simulations against the TCV-X21 reference case and provides insights into the neutral dynamics and ionization source distribution in this scenario. TCV-X21 is a well-diagnosed diverted L-mode sheath-limited plasma scenario in both toroidal field directions, designed specifically for the validation of turbulence codes [D.S. Oliveira, T. Body, et al 2022 Nucl. Fusion 62 096001]. Despite the optimization to reduce the impact of the neutral dynamics, the absence of neutrals in previous turbulence simulations of TCV-X21 was identified as a possible explanation for the disagreements with the experimental data in the divertor region. This motivates the present study with SOLPS-ITER that includes kinetic neutral dynamics via EIRENE. Five new observables are added to the extensive, publicly available TCV-X21 dataset. These are three deuterium Balmer lines in the divertor and neutral pressure in the common and private flux regions. The quantitative agreement metric is combined with the conjugate gradient method to approach the SOLPS-ITER input parameters that return the best overall agreement with the experiment. A proof-of-principle of this method results in a modest improvement in the level-of-agreement; shortcomings of the method and how to improve it are discussed. Alternatively, a scan of the particle and heat diffusion coefficients shows an improvement of 10.4% beyond the agreement level achieved by the gradient method. The result is found for an increased transport coefficient compared to what is usually used for TCV L-mode plasmas, suggesting the need for accurate self-consistent turbulence models for predictive boundary simulations. The simulations indicate that ~65% of the total ionization occurs in the SOL, motivating the inclusion of neutrals in future turbulence simulations towards improved agreement with the experiment.

physics.plasm-ph

Comparison of detachment in Ohmic plasmas with positive and negative triangularity

In recent years, negative triangularity (NT) has emerged as a potential high-confinement L-mode reactor solution. In this work, detachment is investigated using core density ramps in lower single null Ohmic L-mode plasmas across a wide range of upper, lower, and average triangularity (the mean of upper and lower triangularity: $\delta$) in the TCV tokamak. It is universally found that detachment is more difficult to access for NT shaping. The outer divertor leg of discharges with $\delta\approx -0.3$ could not be cooled to below $5~\mathrm{eV}$ through core density ramps alone. The behavior of the upstream plasma and geometrical divertor effects (e.g. a reduced connection length with negative lower triangularity) do not fully explain the challenges in detaching NT plasmas. Langmuir probe measurements of the target heat flux widths ($\lambda_q$) were constant to within 30% across an upper triangularity scan, while the spreading factor $S$ was lower by up to 50% for NT, indicating a generally lower integral Scrape-Off Layer width, $\lambda_{int}$. The line-averaged core density was typically higher for NT discharges for a given fuelling rate, possibly linked to higher particle confinement in NT. Conversely, the divertor neutral pressure and integrated particle fluxes to the targets were typically lower for the same line-averaged density, indicating that NT configurations may be closer to the sheath-limited regime than their PT counterparts, which may explain why NT is more challenging to detach.

physics.plasm-ph

Parallel flows as a key component to interpret Super-X divertor experiments

The Super-X Divertor (SXD) is an alternative divertor configuration leveraging total flux expansion at the Outer Strike Point (OSP). While the extended 2-Point Model (2PM) predicts facilitated detachment access and control in the SXD configuration, these attractive features are not always retrieved experimentally. These discrepancies are at least partially explained by the effect of parallel flows which, when self-consistently included in the 2PM, reveal the role of total flux expansion on the pressure balance and weaken the total flux expansion effect on detachment access and control, compared to the original predictions. This new model can partially explain the discrepancies between the 2PM and experiments performed on tokamak \`a configuration variable (TCV), in ohmic L-mode scenarios, which are particularly apparent when scanning the OSP major radius Rt. In core density ramps in lower Single-Null (SN) configuration, the impact of Rt on the CIII emission front movement in the divertor outer leg - used as a proxy for the plasma temperature in the divertor - is substantially weaker than 2PM predictions. Furthermore, in OSP radial sweeps in lower and upper SN configurations, in ohmic L-mode scenarios with a constant core density, the peak parallel particle flux density at the OSP is almost independent of Rt, while the 2PM predicts a linear dependence. Finally, analytical and numerical modeling of parallel flows in the divertor is presented. It is shown that an increase in total flux expansion can favour supersonic flows at the OSP. Parallel flows are also shown to be relevant by analysing SOLPS-ITER simulations of TCV.

physics.plasm-ph

Performance assessment of a tightly baffled, long-legged divertor configuration in TCV with SOLPS-ITER

Numerical simulations explore the possibility to test the tightly baffled, long-legged divertor (TBLLD) concept in a future upgrade of the Tokamak \`a configuration variable (TCV). The SOLPS-ITER code package is used to compare the exhaust performance of several TBLLD configurations with existing unbaffled and baffled TCV configurations. The TBLLDs feature a range of radial gaps between the separatrix and the outer leg side walls. All considered TBLLDs are predicted to lead to a denser and colder plasma in front of the targets and improve the power handling by factors of 2-3 compared to the present, baffled divertor and by up to a factor of 12 compared to the original, unbaffled configuration. The improved TBLLD performance is mainly due to a better neutral confinement with improved plasma-neutral interactions in the divertor region. Both power handling capability and neutral confinement increases when reducing the radial gap. The core compatibility of TBLLDs with nitrogen seeding is also evaluated and the detachment window with acceptable core pollution for the proposed TBLLDs is explored, showing a reduction of required upstream impurity concentration up to 18% to achieve the detachment with thinner radial gap.

physics.plasm-ph

Improved Heat and Particle Flux Mitigation in High Core Confinement, Baffled, Alternate Divertor Configurations in the TCV tokamak

Nitrogen seeded detachment has been achieved in the Tokamak a Configuration Variable (TCV) in advanced divertor configurations (ADCs), namely X-divertor and X-point target, with and without baffles in H-mode plasmas with high core confinement. Both ADCs show a remarkable reduction in the inter-ELM particle and heat fluxes to the target compared to the standard divertor configuration. 95-98% of the peak heat flux to the target is mitigated as a synergetic effect of ADCs, baffling, and nitrogen seeded detachment. The effect of divertor geometry and baffles on core-divertor compatibility is investigated in detail. The power balance in these experiments is also investigated to explore the physics behind the observed reduction in heat fluxes in the ADCs.

physics.plasm-ph

Validation of edge turbulence codes against the TCV-X21 diverted L-mode reference case

Self-consistent full-size turbulent-transport simulations of the divertor and SOL of existing tokamaks have recently become feasible. This enables the direct comparison of turbulence simulations against experimental measurements. In this work, we perform a series of diverted Ohmic L-mode discharges on the TCV tokamak, building a first-of-a-kind dataset for the validation of edge turbulence models. This dataset, referred to as TCV-X21, contains measurements from 5 diagnostic systems -- giving a total of 45 1- and 2-D comparison observables in two toroidal magnetic field directions. The dataset is used to validate three flux-driven 3D fluid-turbulence models: GBS, GRILLIX and TOKAM3X. With each model, we perform simulations of the TCV-X21 scenario, tuning the particle and power source rates to achieve a reasonable match of the upstream separatrix value of density and electron temperature. We find that the simulations match the experimental profiles for most observables at the OMP -- both in terms of profile shape and absolute magnitude -- while a poorer agreement is found towards the divertor targets. The match between simulation and experiment is seen to be sensitive to the value of the resistivity, the heat conductivities, the power injection rate and the choice of sheath boundary conditions. Additionally, despite targeting a sheath-limited regime, the discrepancy between simulations and experiment also suggests that the neutral dynamics should be included. The results of this validation show that turbulence models are able to perform simulations of existing devices and achieve reasonable agreement with experimental measurements. Where disagreement is found, the validation helps to identify how the models can be improved. By publicly releasing the experimental dataset, this work should help to guide and accelerate the development of predictive turbulence simulations of the edge and SOL.

physics.plasm-ph