Searcharxiv⌕ Search

arXiv subjects

C. Curceanu

Publications and source records attributed to C. Curceanu.

At least 19 recordsLinked to original sources

Kaonic Atom X-ray Spectroscopy: From SIDDHARTA-2 to the EXKALIBUR Program

X-ray spectroscopy of kaonic atoms offers a unique experimental window on the interplay between low-energy strong interaction and precision atomic physics studies. This article reviews the scientific progress achieved with SIDDHARTA-2 at DAFNE and discusses how it shapes the next generation measurements. Particular emphasis is given to EXKALIBUR, a multifacility program designed to perform measurements of kaon-nucleus interactions across the periodic table and to extend kaonic atom spectroscopy toward precision tests of bound-state QED and the charged-kaon mass extraction. The first proposed strong interaction campaign at J-PARC aims to investigate kaonic atoms with solid Li, Be, and B targets using new 1-mm-thick Silicon Drift Detectors and high-resolution TES microcalorimeters, exploiting isotope pairs to isolate nuclear-structure and kaon-multinucleon effects. Measurements of Mg, Al, Si, and S with CdZnTe detectors will broaden this study toward heavier nuclei. EXKALIBUR will establish a systematic experimental framework for testing low-energy strong interaction with strangeness and bound-state QED predictions across a broad range of kaonic atoms.

physics.atom-ph↗

High-precision measurement of the kaonic hydrogen 1s level shift and width with SIDDHARTA-2

Kaonic atoms provide a unique experimental probe of strong interaction in the low-energy regime. In particular, the strong-interaction-induced shift ($\varepsilon_{1\text{s}}$) and width ($Γ_{1\text{s}}$) of kaonic hydrogen directly constrain the low-energy antikaon-nucleon ($\bar{K}N$) interaction at threshold and the theoretical description of the $Λ$(1405) resonance. We report a new high-precision measurement of kaonic hydrogen X-ray transitions performed by the SIDDHARTA-2 experiment at the DA$Φ$NE collider (INFN-LNF), based on an integrated luminosity of 237 pb$^{-1}$. The extracted values, $\varepsilon_{1\text{s}}\,=\,-303.0\,\pm\,17.0\,(stat.)\,\pm\,2.5\,(syst.)$ eV and $Γ_{1\text{s}}\,=\,607\,\pm\,62\,(stat.)\,\pm\,6\,(syst.)$ eV, represent the most precise determination to date, improving the precision by approximately a factor-of-two with respect to the previous SIDDHARTA measurement. These results significantly tighten the experimental constraints on theoretical description of the low-energy $\bar{K}N$ interaction.

nucl-ex↗

Bound-state QED test above the Schwinger limit with kaonic fluorine

Kaonic atoms, formed when a negatively charged kaon replaces an electron in an atomic orbit, provide access to bound-state quantum electrodynamics (BSQED) in electromagnetic fields far stronger than in ordinary atoms. Here, we report an experimental test of BSQED in a regime where the mean Coulomb field exceeds the Schwinger limit. Using high-precision x-ray spectroscopy of kaonic fluorine with the SIDDHARTA-2 experiment at DA$Φ$NE, corresponding to an integrated luminosity of 22.4 pb$^{-1}$, we observe transitions involving the 4f and 3d levels, probing field-to-Schwinger-limit ratios of 1.11 and 3.70, respectively. The measured transition energies agree with state-of-the-art Dirac-Fock calculations. In particular, the 5g-4f transition showing a residual of 5.8 $\pm$ 4.7 (stat.) $\pm$ 5.5 (syst.) eV and a $\sim$ 9$σ$ sensitivity to QED contributions. These results provide a direct test of BSQED in the strong-field regime of QED above the Schwinger limit, opening a new avenue for precision studies in extreme electromagnetic fields.

physics.atom-ph↗

Challenging Spontaneous Quantum Collapse with XENONnT

We report on the search for X-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the X-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. The original values proposed for the strength and the correlation length of the continuous spontaneous localization model are excluded experimentally for the first time.

hep-ex↗

New 1mm thick Silicon Drift Detectors for future researches of Kaonic Atoms and the Pauli Exclusion principle

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a sensitive probe of the low-energy strong interaction via precision X-ray spectroscopy. The SIDDHARTA-2 experiment at the DA$Φ$NE collider employs high-performance Silicon Drift Detectors (SDDs) optimized for the 4-12 keV range to study light kaonic systems. In preparation for the EXKALIBUR phase, which targets heavier kaonic atoms, new 1 mm-thick SDDs have been developed with Politecnico di Milano and Fondazione Bruno Kessler. Their increased thickness enhances the quantum efficiency by a factor of about two at 30 keV while preserving excellent energy resolution. These detectors are also intended for VIP-3, the next-generation test of the Pauli Exclusion Principle (PEP). Building on VIP-2, which set the most stringent limits on PEP-violating $K_α$ transitions in copper, VIP-3 will extend the search to heavier elements such as Ag, Sn, and Zr. Preliminary measurements demonstrate efficient detection up to 30 keV, supporting future high-precision studies of the kaon-nucleon interaction and PEP in heavier systems.

physics.ins-det↗

Measurement of $^{3,4}$He($K^-, π^0$)$^{3,4}_Λ$H reaction cross section and evaluation of hypertriton $Λ$ binding energy

Light $s$-shell hypernuclei ($^{3,4}_Λ\text{H}$) and their ground-state properties are crucial benchmarks in hypernuclear physics. In particular, comparing the production cross sections of $^{3}_Λ\text{H}$ and $^{4}_Λ\text{H}$ provides insights into the $ΛN$ interaction in different isospin configurations, which can help address recent discrepancies in the reported $Λ$ binding energy of hypertriton. We present the first measurement of the production cross sections for $^{3}_Λ\text{H}$ and $^{4}_Λ\text{H}$ using the in-flight $(K^-, π^0)$ reaction at a beam momentum of 1.0 GeV/$c$ with an identical experimental setup. The production cross sections in the laboratory frame, for the angular range from 0$^{\circ}$ to 20$^{\circ}$, are measured to be $15.0~\pm~2.6~(\text{stat.})~^{+2.4}_{-2.8}~(\text{syst.})~μ\text{b} $ and $49.9~\pm~2.1~(\text{stat.})~^{+7.8}_{-8.0}~(\text{syst.})~μ\text{b}$ for the ground-state of $^{3}_Λ\text{H}$ and $^{4}_Λ\text{H}$, respectively. Using the ratio of these cross sections and comparing it with theoretical calculations, we evaluate the $Λ$ binding energy of hypertriton, yielding a value consistent with the picture of a loosely bound system.

nucl-ex↗

Nuclear Physics Mid Term Plan at LNGS

The Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Gran Sasso (LNGS) is one of the largest underground physics laboratory, a very peculiar environment suited for experiments in Astroparticle Physics, Nuclear Physics and Fundamental Symmetries. The newly established Bellotti Ion Beam facility represents a major advance in the possibilities of studying nuclear processes in an underground environment. A workshop was organized at LNGS in the framework of the Nuclear Physics Mid Term Plan in Italy, an initiative of the Nuclear Physics Division of the Instituto Nazionale di Fisica Nucleare to discuss the opportunities that will be possible to study in the near future by employing state-of-the-art detection systems. In this report, a detailed discussion of the outcome of the workshop is presented.

nucl-ex↗

Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector

A direct test of the CPT symmetry is performed for the electromagnetic decays of ortho-positronium using the J-PET tomograph. We present the precise measurement of the CPT-sensitive angular correlation entailing the positronium spin and the momenta of its annihilation photons, surpassing previous studies utilizing the same detection system. Positrons originating from a $^{22}$Na source are emitted from the detector's center and subsequently form positronium atoms within the spherical chamber covered with porous material. Reconstruction of annihilation locations using the 192-strip J-PET detector makes it possible to determine the positronium emission direction, which defines the quantization axis along which positronium is polarized, without the application of external magnetic fields. The measurements were performed in total for 356 days resulting in an identification of 47.8 million events with ortho-positronium decays into three photons. The results are consistent with the exactness of CPT symmetry with measured asymmetry amplitude -0.00029 $\pm$ 0.00022 (stat.) and with statistical error four times smaller than the previous best measurement.

nucl-ex↗

First experimental measurements of biophotons from Astrocytes and Glioblastoma cell cultures

Biophotons are non-thermal and non-bioluminescent ultraweak photon emissions, first hypothesised by Gurwitsch in 1924 as a regulatory mechanism in cell division, and then experimentally observed in living organisms. Today, two main hypotheses explain their origin: stochastic decay of excited molecules and coherent electromagnetic fields produced in biochemical processes. Recent interest focuses on the role of biophotons in cellular communication and disease monitoring. This study presents the first campaign of biophoton emission measurements from cultured astrocytes and glioblastoma cells, conducted at Fondazione Pisana per la Scienza (FPS) using two ultra-sensitive setups developed by the collaboration at the National Laboratories of Frascati (LNF-INFN) and at the University of Rome II - Tor Vergata. The statistical analyses of the data collected revealed a clear separation between cellular signals and dark noise, confirming the high sensitivity of the apparatuses. The Diffusion Entropy Analysis (DEA) was applied to the data to uncover dynamic patterns, revealing anomalous diffusion and long-range memory effects potentially related to intercellular signalling and cellular communication. These findings support the hypothesis that biophoton emissions encode rich information beyond intensity, reflecting metabolic and pathological states. The differences that emerged from the application of Diffusion Entropy Analysis to the biophotonic signals of Astrocytes and Glioblastoma are highlighted and discussed in the paper. This work lays the foundation for future studies on neuronal cultures and proposes biophoton dynamics as a promising tool for non-invasive diagnostics and cellular communication research.

physics.bio-ph↗

Precision Test of Bound-State QED at Intermediate-Z with Kaonic Neon

We report Dirac-Fock calculations of transition energies for kaonic neon (KNe). For the most intense line, the 7-6 transition, the calculated energy is 9450.28 eV, which includes a bound-state QED (BSQED) contribution of 12.66 eV. This is in excellent agreement with the recent SIDDHARTHA-2 measurement at DA$Φ$NE of 9450.23 $\pm$ 0.37 (stat.) $\pm$ 1.50 (syst.) eV. With the QED shift far exceeding experimental uncertainty, these results establish kaonic atoms as powerful platforms for precision tests of BSQED in intermediate-Z systems.

physics.atom-ph↗

Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner

In state-of-the-art Positron Emission Tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum-entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and para-positronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening new avenues for exploring polarization correlations in PET as a diagnostic indicator.

nucl-ex↗

Search for Pauli Exclusion Principle Violations with Gator at LNGS

The Pauli Exclusion Principle (PEP) appears from fundamental symmetries in quantum field theories, but its physical origin is still to be understood. High-precision experimental searches for small PEP violations permit testing key assumptions of the Standard Model with high sensitivity. We report on a dedicated measurement with Gator, a low-background, high-purity germanium detector operated at the Laboratori Nazionali del Gran Sasso, aimed at testing PEP-violating atomic transitions in lead. The experimental technique, relying on forming a new symmetry state by introducing electrons into the pre-existing electron system through a direct current, satisfies the conditions of the Messiah-Greenberg superselection rule. No PEP violation has been observed, and an upper limit on the PEP violation probability of $β^2/2 < 4.8 \cdot 10^{-29}$ (90% CL) is set. This improves the previous constraint from a comparable measurement by more than one order of magnitude.

nucl-ex↗

Nanoporosity imaging by positronium lifetime tomography

Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the annihilation of a positron and an electron. Mean positron lifetime in the material depends on the free voids size and molecular environment, allowing the study of porosity and structural transitions in the nanometer scale. We have developed a novel method enabling spatially resolved PALS, thus providing tomography of nanostructural characterization of an extended object. Correlating space (position) and structural (lifetime) information brings new insight in materials studies, especially in the characterization of the purity and pore distribution. For the first time, a porosity image using stationary positron sources for the simultaneous measurement of the porous polymers XAD4, silica aerogel powder IC3100, and polyvinyl toluene scintillator PVT by the J-PET tomograph is demonstrated

physics.app-ph↗

Mini-Proceedings of the "Fourth International Workshop on the Extension Project for the J-PARC Hadron Experimental Facility (HEF-ex 2024)"

The mini proceedings of the "Fourth International Workshop on the Extension Project for the J-PARC Hadron Experimental Facility (HEF-ex 2024) [https://kds.kek.jp/event/46965]" held at J-PARC, February 19-21, 2024, are presented. The workshop was devoted to discussing the physics case that connects both the present and the future Hadron Experimental Facility at J-PARC, covering a wide range of topics in flavor, hadron, and nuclear physics related to both experimental and theoretical activities being conducted at the facility.

nucl-ex↗

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.

physics.med-ph↗

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 +- 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 +- 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.

physics.med-ph↗

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.

physics.ins-det↗

Measurement of the mesonic decay branch of the $\bar{K}\!N\!N$ quasi-bound state

We conducted measurements of $K^- + {^3{\rm He}} \to π\!Y \!N + N'$ reactions using a $1~{\rm GeV}/c$ $K^-$-beam, with the objective of understanding the broad decay width of $\bar{K} \!N \!N$ (approximately twice as broad as that of $Λ(1405)$ considered to be the $\bar{K} \!N$ quasi-bound state). We successfully reproduced distributions of the $π\! Y \! N$ invariant mass and momentum transfer for $π\! Y \! N$ using model fitting functions for $\bar{K} \!N \!N$ formation and quasi-free $\bar{K}$ absorption (${\rm QF}_{\bar{K}-{\rm abs}}$) processes. The model can describe the experimental data quite well, and four $\bar{K} \! N \! N \to π\! Y \! N $ cross-sections were obtained. The results indicate that mesonic decay is the dominant decay branch of $\bar{K} \! N \! N$. The results also suggest that $Γ_{πΛN} \sim Γ_{πΣN}$, which indicates that the $I_{\bar{K} \! N}=1$ absorption channel, in addition to the $I_{\bar{K} \! N}=0$ absorption channel, substantially contribute to the $\bar{K} \! N \! N$ decay, making the $\bar{K} \! N \! N$ state approximately twice as unstable as $Λ$(1405).

nucl-ex↗