SearcharxivSearch

arXiv subjects

C. Durandet

Publications and source records attributed to C. Durandet.

11 recordsLinked to original sources

Scaling slowly rotating asteroids by stellar occultations

As evidenced by recent survey results, majority of asteroids are slow rotators (P>12 h), but lack spin and shape models due to selection bias. This bias is skewing our overall understanding of the spins, shapes, and sizes of asteroids, as well as of their other properties. Also, diameter determinations for large (>60km) and medium-sized asteroids (between 30 and 60 km) often vary by over 30% for multiple reasons. Our long-term project is focused on a few tens of slow rotators with periods of up to 60 hours. We aim to obtain their full light curves and reconstruct their spins and shapes. We also precisely scale the models, typically with an accuracy of a few percent. We used wide sets of dense light curves for spin and shape reconstructions via light-curve inversion. Precisely scaling them with thermal data was not possible here because of poor infrared data: large bodies are too bright for WISE mission. Therefore, we recently launched a campaign among stellar occultation observers, to scale these models and to verify the shape solutions, often allowing us to break the mirror pole ambiguity. The presented scheme resulted in shape models for 16 slow rotators, most of them for the first time. Fitting them to stellar occultations resolved previous inconsistencies in size determinations. For around half of the targets, this fitting also allowed us to identify a clearly preferred pole solution, thus removing the ambiguity inherent to light-curve inversion. We also address the influence of the uncertainty of the shape models on the derived diameters. Overall, our project has already provided reliable models for around 50 slow rotators. Such well-determined and scaled asteroid shapes will, e.g. constitute a solid basis for density determinations when coupled with mass information. Spin and shape models continue to fill the gaps caused by various biases.

astro-ph.EP

The SeaQuest Spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

physics.ins-det

Study of the rare hyperon decay Omega \to Xi π^+ π^-

We report a new measurement of the decay Ω^- \to Ξ^- π^+ π^- with 76 events and a first observation of the decay Ω^+ \to Ξ^+ π^+ π^- with 24 events, yielding a combined branching ratio (3.74 ^{+0.67}_{-0.56}) \times 10^{-4}. This represents a factor 25 increase in statistics over the best previous measurement. No evidence is seen for CP violation, with B(Ω^- \to Ξ^- π^+ π^-)=4.04^{+0.83}_{-0.71} \times 10^{-4} and B(Ω^+ \to Ξ^+ π^+ π^-)=3.15^{+1.12}_{-0.89} \times 10^{-4}. Contrary to theoretical expectation, we see little evidence for the decays Ω^- \to Ξ_{1530}^{*0} π^- and Ω^+ \to Ξ_{1530}^{*0} π^+ and place a 90% C.L. upper limit on the combined branching ratio B(Ω^-(Ω^+) \to Ξ^{*0}_{1530}(Ξ^{*0}_{1530}) π^\mp)<7.0 \times 10^{-5}.

hep-ex

Search for the Lepton-Number-Violating Decay $Ξ^- \to p μ^- μ^-$

A sensitive search for the lepton-number-violating decay $Ξ^-\to p μ^-μ^-$ has been performed using a sample of $\sim10^9$ $Ξ^-$ hyperons produced in 800 GeV/$c$ $p$-Cu collisions. We obtain $\mathcal{B}(Ξ^-\to p μ^-μ^-)< 4.0\times 10^{-8}$ at 90% confidence, improving on the best previous limit by four orders of magnitude.

hep-ex

Observation of Parity Violation in the Omega-minus -> Lambda + K-minus Decay

The alpha decay parameter in the process Omega-minus -> Lambda + K-minus has been measured from a sample of 4.50 million unpolarized Omega-minus decays recorded by the HyperCP (E871) experiment at Fermilab and found to be [1.78 +/- 0.19(stat) +/- 0.16(syst)]{\times}10^{-2}. This is the first unambiguous evidence for a nonzero alpha decay parameter, and hence parity violation, in the Omega-minus -> Lambda + K-minus decay.

hep-ex

delta S = 2 nonleptonic hyperon decays

A sensitive search for the rare decays Ω^- \to Λπ^- and Ξ^0 \to p π^- has been performed using data from the 1997 run of the HyperCP (Fermilab E871) experiment. Limits on other such processes do not exclude the possibility of observable rates for |ΔS| = 2 nonleptonic hyperon decays, provided the decays occur through parity-odd operators. We obtain the branching-fraction limits B(Ω^- \to Λπ^-)< 2.9 x 10^{-6} and B(Ξ^0 \to p π^-)< 8.2 x 10^{-6}, both at 90% confidence level.

hep-ex

Measurement of the Alpha Asymmetry Parameter for the Omega- to Lambda K- Decay

We have measured the alpha parameter of the Omega- to Lambda K- decay using data collected with the HyperCP spectrometer during the 1997 fixed-target run at Fermilab. Analyzing a sample of 0.96 million Omega- to Lambda K^-, Lambda to p pi- decays, we obtain alpha_Omega*alpha_Lambda = [1.33+/-0.33(stat)+/-0.52(syst)] x 10^{-2}. With the accepted value of alpha_Lambda, alpha_Omega is found to be [2.07+/-0.51(stat)+/-0.81(syst)] x 10^{-2}.

hep-ex

Evidence for the Decay Sigma+ -> p mu+ mu-

We report the first evidence for the decay Sigma+ -> p mu+ mu- from data taken by the HyperCP experiment(E871) at Fermilab. Based on three observed events, the branching ratio is B(Sigma+ -> p,mu+,mu-) = [8.6 +6.6,-5.4(stat) +/-5.5(syst)] x 10**-8. The narrow range of dimuon masses may indicate that the decay proceeds via a neutral intermediate state, Sigma+ -> p P0, P0 -> mu+ mu-, with a P0 mass of 214.3 +/- 0.5 MeV/c**2 and branching ratio B(Sigma+ -> p P0; P0 -> mu+ mu-) = [3.1 +2.4,-1.(stat) +/-1.5(syst)] x 10**-8.

hep-ex

Search for CP Violation in Charged-Xi and Lambda Hyperon Decays

We have compared the proton and antiproton angular distributions in 117 million Xi-minus -> Lambda + pi-minus -> proton + pi-minus + pi-minus and 41 million anti-Xi-minus -> anti-Lamba + pi-plus -> antiproton + pi-plus + pi-plus decays using a subset of the data from the HyperCP experiment (E871) at Fermilab. We find no evidence of CP violation, with the direct-CP-violating parameter $A_{ΞΛ} = \frac{α_Ξα_Λ - \barα_Ξ\barα_Λ}{α_Ξα_Λ + \barα_Ξ\barα_Λ} = [0.0+/-5.1(stat)+/-4.4(syst)]{\times}10^{-4}$.

hep-ex

High Statistics Search for the Theta+(1.54) Pentaquark State

We have searched for Theta+(1.54) -> K0,p decays using data from the 1999 run of the HyperCP experiment at Fermilab. We see no evidence for a narrow peak in the K0,p mass distribution near 1.54 GeV/c among 106,000 K0,p candidates, and obtain an upper limit for the fraction of Theta+(1.54) to K0,p candidates of <0.3% at 90% confidence.

hep-ex

HyperCP: A high-rate spectrometer for the study of charged hyperon and kaon decays

The HyperCP experiment (Fermilab E871) was designed to search for rare phenomena in the decays of charged strange particles, in particular CP violation in $Ξ$ and $Λ$ hyperon decays with a sensitivity of $10^{-4}$. Intense charged secondary beams were produced by 800 GeV/c protons and momentum-selected by a magnetic channel. Decay products were detected in a large-acceptance, high-rate magnetic spectrometer using multiwire proportional chambers, trigger hodoscopes, a hadronic calorimeter, and a muon-detection system. Nearly identical acceptances and efficiencies for hyperons and antihyperons decaying within an evacuated volume were achieved by reversing the polarities of the channel and spectrometer magnets. A high-rate data-acquisition system enabled 231 billion events to be recorded in twelve months of data-taking.

hep-ex