SearcharxivSearch

arXiv subjects

C. Echevarria

Publications and source records attributed to C. Echevarria.

6 recordsLinked to original sources

High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay $0\nu\beta\beta$. The feedthrough has been demonstrated to hold pressures up to 20~bar and sustain voltages as high as -65~kV, and the TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses.

physics.ins-det

Performance of an Optical TPC Geant4 Simulation with Opticks GPU-Accelerated Photon Propagation

We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47+/-0.02 and 181.39+/-0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.

physics.ins-det

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle $\cos\theta$ among the two decay electrons, and the electron energy spectra, $T_1$ and $T_2$. In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{\cos\theta}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

hep-ex

Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.

hep-ex

Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe

The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.

physics.ins-det

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterr\'aneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

physics.ins-det