SearcharxivSearch

arXiv subjects

C. Ferrari

Publications and source records attributed to C. Ferrari.

At least 55 records · Page 3Linked to original sources

Detector signal characterization with a Bayesian network in XENONnT

We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ionization process. We describe the method and its performance on electronic-recoil (ER) data taken during the first science run of the XENONnT dark matter experiment. We demonstrate the first use of a Bayesian network in a waveform-based analysis of detector signals. This method resulted in a 3% increase in ER event-selection efficiency with a simultaneously effective rejection of events outside of the region of interest. The findings of this analysis are consistent with the previous analysis from XENONnT, namely a background-only fit of the ER data.

hep-ex

Cosmogenic background simulations for the DARWIN observatory at different underground locations

Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.

physics.ins-det

Searching for Heavy Dark Matter near the Planck Mass with XENON1T

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This work places strong constraints on spin-independent interactions of dark matter particles with a mass between 1$\times$10$^{12}\,$GeV/c$^2$ and 2$\times$10$^{17}\,$GeV/c$^2$. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections for dark matter particles with masses close to the Planck scale.

hep-ex

Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.

physics.ins-det

CdTe Spectroscopic-Imager Measurements with Bent Crystals for Broad Band Laue Lenses

In astrophysics, several key questions in the hard X soft Gamma-ray range (above 100 keV) require sensitivity and angular resolution that are hardly achievable with current technologies. Therefore, a new kind of instrument able to focus hard X and gamma-rays is essential. Broad band Laue lenses seem to be the only solution to fulfil these requirements, significantly improving the sensitivity and angular resolution of the X and gamma-ray telescopes. This type of high-energy optics will require highly performing focal plane detectors in terms of detection efficiency, spatial resolution, and spectroscopy. This paper presents the results obtained in the project 'Technological Readiness Increase for Laue Lenses (TRILL)' framework using a Caliste-HD detector module. This detector is a pixel spectrometer developed at CEA (Commissariat a Energie Atomique, Saclay, France). It is used to acquire spectroscopic images of the focal spot produced by Laue Lens bent crystals under a hard X-ray beam at the LARIX facility (University of Ferrara, Italy).

astro-ph.IM

The Triggerless Data Acquisition System of the XENONnT Experiment

The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at $\times10$ and $\times0.5$ gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within $\mathcal{O}\left(10\text{ s}\right)$ for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed $\sim500$ MB/s during calibration. Livetime during normal operation exceeds $99\%$ and is $\sim90\%$ during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.

physics.ins-det

Laue lenses: Focusing optics for hard X/soft Gamma-ray Astronomy

Hard X-/soft Gamma-ray astronomy is a key field for the study of important astrophysical phenomena such as the electromagnetic counterparts of gravitational waves, gamma-ray bursts, black holes physics and many more. However, the spatial localization, imaging capabilities and sensitivity of the measurements are strongly limited for the energy range $>$70 keV due to the lack of focusing instruments operating in this energy band. A new generation of instruments suitable to focus hard X-/ soft Gamma-rays is necessary to shed light on the nature of astrophysical phenomena which are still unclear due to the limitations of current direct-viewing telescopes. Laue lenses can be the answer to those needs. A Laue lens is an optical device consisting of a large number of properly oriented crystals which are capable, through Laue diffraction, of concentrating the radiation into the common Laue lens focus. In contrast with the grazing incidence telescopes commonly used for softer X-rays, the transmission configuration of the Laue lenses allows us to obtain a significant sensitive area even at energies of hundreds of keV. At the University of Ferrara we are actively working on the modelization and construction of a broad-band Laue lens. In this work we will present the main concepts behind Laue lenses and the latest technological developments of the TRILL (Technological Readiness Increase for Laue Lenses) project, devoted to the advancement of the technological readiness of Laue lenses by developing the first prototype of a lens sector made of cylindrical bent crystals of Germanium.

astro-ph.IM

ASTENA: a mission concept for a deep study of the transient gamma-ray sky and for nuclear astrophysics

Gamma-ray astronomy is a branch whose potential has not yet been fully exploited. The observations of elemental and isotopic abundances in supernova (SN) explosions are key probes not only of the stellar structure and evolution but also for understanding the physics that makes Type-Ia SNe as standard candles for the study of the Universe expansion properties. In spite of its crucial role, nuclear astrophysics remains a poorly explored field mainly for the typical emission lines intensity which are vanishing small and requires very high sensitivities of the telescopes. Furthermore, in spite that the Galactic bulge-dominated intensity of positron annihilation line at 511 keV has been measured, its origin is still a mystery due to the poor angular resolution and insufficient sensitivity of the commonly employed instrumentation in the sub-MeV energy domain. To answer these scientific issues a jump in sensitivity and angular resolution with respect to the present instrumentation is required. Conceived within the EU project AHEAD, a new high energy mission, capable of tackling the previously mentioned topics, has been proposed. This concept of mission named ASTENA (Advanced Surveyor of Transient Events and Nuclear Astrophysics), includes two instruments: a Wide Field Monitor with Imaging and Spectroscopic (WFM-IS, 2 keV - 20 MeV) capabilities and a Narrow Field Telescope (NFT, 50 - 700 keV). Thanks to the combination of angular resolution, sensitivity and large FoV, ASTENA will be a breakthrough in the hard X and soft gamma--ray energy band, also enabling polarimetry in this energy band. In this talk the science goals of the mission are discussed, the payload configuration is described and expected performances in observing key targets are shown.

astro-ph.IM

Search for New Physics in Electronic Recoil Data from XENONnT

We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

hep-ex

The Florence 4D Facial Expression Dataset

Human facial expressions change dynamically, so their recognition / analysis should be conducted by accounting for the temporal evolution of face deformations either in 2D or 3D. While abundant 2D video data do exist, this is not the case in 3D, where few 3D dynamic (4D) datasets were released for public use. The negative consequence of this scarcity of data is amplified by current deep learning based-methods for facial expression analysis that require large quantities of variegate samples to be effectively trained. With the aim of smoothing such limitations, in this paper we propose a large dataset, named Florence 4D, composed of dynamic sequences of 3D face models, where a combination of synthetic and real identities exhibit an unprecedented variety of 4D facial expressions, with variations that include the classical neutral-apex transition, but generalize to expression-to-expression. All these characteristics are not exposed by any of the existing 4D datasets and they cannot even be obtained by combining more than one dataset. We strongly believe that making such a data corpora publicly available to the community will allow designing and experimenting new applications that were not possible to investigate till now. To show at some extent the difficulty of our data in terms of different identities and varying expressions, we also report a baseline experimentation on the proposed dataset that can be used as baseline.

cs.CV

An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

physics.ins-det

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

physics.ins-det

First light of BEaTriX, the new testing facility for the modular X-ray optics of the ATHENA mission

The Beam Expander Testing X-ray facility (BEaTriX) is a unique X-ray apparatus now operated at the Istituto Nazionale di Astrofisica (INAF), Osservatorio Astronomico di Brera (OAB), in Merate, Italy. It has been specifically designed to measure the point spread function (PSF) and the effective area (EA) of the X-ray mirror modules (MMs) of the Advanced Telescope for High-ENergy Astrophysics (ATHENA), based on silicon pore optics (SPO) technology, for verification before integration into the mirror assembly. To this end, BEaTriX generates a broad, uniform, monochromatic, and collimated X-ray beam at 4.51 keV. [...] In BEaTriX, a micro-focus X-ray source with a titanium anode is placed in the focus of a paraboloidal mirror, which generates a parallel beam. A crystal monochromator selects the 4.51 keV line, which is expanded to the final size by a crystal asymmetrically cut with respect to the crystalline planes. [...] After characterization, the BEaTriX beam has the nominal dimensions of 170 mm x 60 mm, with a vertical divergence of 1.65 arcsec and a horizontal divergence varying between 2.7 and 3.45 arcsec, depending on the monochromator setting: either high collimation or high intensity. The flux per area unit varies from 10 to 50 photons/s/cm2 from one configuration to the other. The BEaTriX beam performance was tested using an SPO MM, whose entrance pupil was fully illuminated by the expanded beam, and its focus was directly imaged onto the camera. The first light test returned a PSF and an EA in full agreement with expectations. As of today, the 4.51 keV beamline of BEaTriX is operational and can characterize modular X-ray optics, measuring their PSF and EA with a typical exposure of 30 minutes. [...] We expect BEaTriX to be a crucial facility for the functional test of modular X-ray optics, such as the SPO MMs for ATHENA.

astro-ph.IM

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

hep-ex

The ABALONE Photosensor

The ABALONE is a new type of photosensor produced by PhotonLab, Inc. with cost effective mass production, robustness and high performance. This modern technology provides sensitivity to visible and UV light, exceptional radio-purity and excellent detection performance in terms of intrinsic gain, afterpulsing rate, timing resolution and single-photon sensitivity. For these reasons, the ABALONE can have many fields of application, including particle physics experiments, such as DARWIN, and medical imaging. This new hybrid photosensor, that works as light intensifier, is based on the acceleration in vacuum of photoelectrons generated in a traditional photosensor cathode and guided towards a window of scintillating material that can be read from the outside through a silicon photomultiplier. In this work we present the simulation of the ABALONE and the results from operation at room temperature. The goal of the characterization is the evaluation of the gain, the response in time and the single photoelectron spectrum as a function of the electric field and the photoelectron emission angle. Details of future tests will be also discussed.

physics.ins-det

Processing of non-constant baseline pulses: a matrix technique

For a high source activity experiment, such as HOLMES, non-constant baseline pulses could constitute a great fraction of the data-set. We test the optimal filter matrix technique, proposed to process these pulses, on simulated responses of HOLMES microcalorimeters.

physics.data-an

The fast non-ferric kicker system for the Muon $g-2$ Experiment at Fermilab

We describe the installation, commissioning, and characterization of the new injection kicker system in the Muon $g-2$ Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon $g-2$'s predecessor experiment, and we present those details in this manuscript.

physics.ins-det

Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab

This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.

physics.acc-ph